Patient Size-Dependent Dosimetry Methodology Applied to 18F-FDG Using New ICRP Mesh Phantoms

被引:4
作者
Carter, Lukas M. [1 ]
Choi, Chansoo [2 ]
Krebs, Simone [3 ]
Beattie, Bradley J. [1 ]
Kim, Chan Hyeong [2 ]
Schoder, Heiko [3 ]
Bolch, Wesley E. [4 ]
Kesner, Adam L. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Hanyang Univ, Dept Nucl Engn, Seoul, South Korea
[3] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10021 USA
[4] Univ Florida, J Crayton Pruitt Dept Biomed Engn, Gainesville, FL USA
关键词
FDG; patient-dependent dosimetry; PARaDIM; PHITS; phantom; PERSONAL-COMPUTER SOFTWARE; INTERNAL DOSE ASSESSMENT; ADULT; ADOLESCENTS; CAMPAIGN; CANCER; RISK;
D O I
10.2967/jnumed.120.256719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite the known influence of anatomic variability on internal dosimetry, dosimetry for F-18-FDG and other diagnostic radiopharmaceuticals is routinely derived using reference phantoms, which embody population-averaged morphometry fora given age and sex. Moreover, phantom format affects dosimetry estimates to a varying extent. Here, we applied newly developed mesh format reference phantoms and a patient-dependent phantom library to assess the impact of height, weight, and body contour variation on dosimetry of F-18-FDG. We compared the mesh reference phantom dosimetry estimates with corresponding estimates from common software to identify differences related to phantom format or software implementation. Our study serves as an example of how more precise patient size-dependent dosimetry methodology could be performed. Methods: Absorbed dose coefficients were computed for the adult mesh reference phantoms and for a derivative patient-dependent phantom series by Monte Carlo simulation using the Particle and Heavy Ion Transport Code System (PHITS) within the software called PARaDIM (PHITS-Based Application for Radionuclide Dosimetry in Meshes). The dose coefficients were compared with reference absorbed dose coefficients obtained from International Commission on Radiological Protection publication 128 or were generated using software including OLINDA 2.1, OLINDA 1.1, and IDAC-Dose 2.1. Results: Differences in dosimetry arising from anatomic variations were shown to be significant, with detriment-weighted dose coefficients for the percentile-specific phantoms varying by up to +40% relative to the corresponding reference phantom effective dose coefficients, irrespective of phantom format. Similar variations were seen in the individual organ absorbed dose coefficients for the percentile-specific phantoms relative to the reference phantoms. The effective dose coefficient for the mesh reference adult was 0.017 mSv/MBq, which was 5% higher than estimated by a corresponding voxel phantom and 10% lower than estimated by the stylized phantom format. Conclusion: We observed notable variability in F-18-FDG dosimetry across morphometrically different patients, supporting the use of patient-dependent phantoms for more accurate dosimetric estimations relative to standard reference dosimetry. The methodology employed may help in optimizing imaging protocols and research studies, in particular when longer-lived isotopes are used.
引用
收藏
页码:1805 / 1814
页数:10
相关论文
共 40 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms
    Andersson, Martin
    Johansson, Lennart
    Eckerman, Keith
    Mattsson, Soren
    [J]. EJNMMI RESEARCH, 2017, 7
  • [3] [Anonymous], 2007, ANN ICRP, V37, P43
  • [4] [Anonymous], 2020, 2020 PET IMAGING MAR
  • [5] [Anonymous], 2006, HLTH RISKS EXP LOW L, P2
  • [6] [Anonymous], 1975, ICRP PUBLICATION
  • [7] Image Gently: A Campaign to Reduce Children's and Adolescents' Risk for Cancer During Adulthood
    Applegate, Kimberly E.
    Cost, Nicholas G.
    [J]. JOURNAL OF ADOLESCENT HEALTH, 2013, 52 (05) : S93 - S97
  • [8] Bolch W. E., 2016, Annals of the ICRP, V45, P9, DOI 10.1177/0146645316661077
  • [9] Hybrid computational phantoms for medical dose reconstruction
    Bolch, Wesley
    Lee, Choonsik
    Wayson, Michael
    Johnson, Perry
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2010, 49 (02) : 155 - 168
  • [10] MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry-Standardization of Nomenclature
    Bolch, Wesley E.
    Eckerman, Keith F.
    Sgouros, George
    Thomas, Stephen R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) : 477 - 484