Should we use cortical bone screws for cortical bone trajectory?

被引:51
作者
Ueno, Masaki [1 ]
Sakai, Rina [2 ]
Tanaka, Kensei [2 ]
Inoue, Gen [1 ]
Uchida, Kentaro [1 ]
Imura, Takayuki [1 ]
Saito, Wataru [1 ]
Nakazawa, Toshiyuki [1 ]
Takahira, Naonobu [1 ,3 ]
Mabuchi, Kiyoshi [2 ]
Takaso, Masashi [1 ]
机构
[1] Kitasato Univ, Sch Med, Dept Orthopaed Surg, Sagamihara, Kanagawa 228, Japan
[2] Kitasato Univ, Sch Allied Hlth Sci, Dept Biomed Engn, Sagamihara, Kanagawa 228, Japan
[3] Kitasato Univ, Sch Allied Hlth Sci, Dept Rehabil, Sagamihara, Kanagawa 228, Japan
关键词
cortical bone trajectory; screw thread; spinal fusion; pedicle screw; technique; MINERAL DENSITY; SPINE; FIXATION;
D O I
10.3171/2014.9.SPINE1484
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECT In 2009, Santoni et al. reported cortical bone trajectory (CBT) as a method of inserting pedicle screws to obtain more solid fixation, and proposed the use of cortical trajectory screws with a more closely placed thread (cortical screws) for CBT. Since the entry trajectory in CBT differs from that in the traditional trajectory, it is unclear whether the increased strength derives from the specific trajectory or the shape of the screw thread in contact with the cortical bone. Whether the use of cortical screws is always required with CBT thus remains unclear. The authors therefore investigated the relationship between screw entry trajectory and screw thread characteristics and pullout strength in animal experiments. METHODS Lumbar vertebrae (L1-L4) from 4-month-old female pigs were randomly assigned to one of 4 groups, with cancellous screws or cortical screws inserted via the traditional trajectory or CBT. For pullout strength testing, the screw wasiDulled out vertically against the direction of insertion. Rod pullout testing (toggle testing) was also performed, and the peak breaking strength was measured. RESULTS The maximum pullout strength was significantly greater for CBT using cortical screws than for the traditional trajectory using cancellous screws. Pullout strength tended to be higher when cortical screws were used in both CBT and the traditional trajectory, although the difference was not significant. Toggle testing showed no significant differences among the 4 groups. CONCLUSIONS The specific unconventional trajectory seemed to have a major impact on the increased strength obtained with CBT.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 6 条
[1]   Cancellous bone screw thread design and holding power [J].
Asnis, SE ;
Ernberg, JJ ;
Bostrom, MPG ;
Wright, TM ;
Harrington, RM ;
Tencer, A ;
Peterson, M .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (07) :462-469
[2]   EFFECTS OF BONE-MINERAL DENSITY ON PEDICLE SCREW FIXATION [J].
HALVORSON, TL ;
KELLEY, LA ;
THOMAS, KA ;
WHITECLOUD, TS ;
COOK, SD .
SPINE, 1994, 19 (21) :2415-2420
[3]   STABILITY OF TRANSPEDICLE SCREWING FOR THE OSTEOPOROTIC SPINE - AN IN-VITRO STUDY OF THE MECHANICAL STABILITY [J].
OKUYAMA, K ;
SATO, K ;
ABE, E ;
INABA, H ;
SHIMADA, Y ;
MURAI, H .
SPINE, 1993, 18 (15) :2240-2245
[4]   Cortical bone trajectory for lumbar pedicle screws [J].
Santoni, B. G. ;
Hynes, R. A. ;
McGilvray, K. C. ;
Rodriguez-Canessa, G. ;
Lyons, A. S. ;
Henson, M. A. W. ;
Womack, W. J. ;
Puttlitz, C. M. .
SPINE JOURNAL, 2009, 9 (05) :366-373
[5]   AN EXPERIMENTAL-STUDY ON TRANSPEDICULAR SCREW FIXATION IN RELATION TO OSTEOPOROSIS OF THE LUMBAR SPINE [J].
SOSHI, S ;
SHIBA, R ;
KONDO, H ;
MUROTA, K .
SPINE, 1991, 16 (11) :1335-1341
[6]   IMPORTANCE OF BONE-MINERAL DENSITY IN INSTRUMENTED SPINE FUSIONS [J].
WITTENBERG, RH ;
SHEA, M ;
SWARTZ, DE ;
LEE, KS ;
WHITE, AA ;
HAYES, WC .
SPINE, 1991, 16 (06) :647-652