Free-breathing black-blood coronary MR angiography: Initial results

被引:47
|
作者
Stuber, M
Botnar, RM
Kissinger, KV
Manning, WJ
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[3] Harvard Univ, Sch Med, Boston, MA 02215 USA
[4] Philips Med Syst, Best, Netherlands
关键词
coronary angiography; technology; coronary vessels; diseases; stenosis or obstruction; magnetic resonance (MR); vascular studies;
D O I
10.1148/radiology.219.1.r01mr07278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors developed a free-breathing black-blood coronary magnetic resonance (MR) angiographic technique with a potential for exclusive visualization of the coronary blood pool. Results with the MR angiographic technique were evaluated in eight healthy subjects and four patients with coronary disease identified at conventional angiography. This MR angiographic technique accurately depicted luminal disease in the patients and permitted visualization of extensive continuous segments of the native coronary tree in both the healthy subjects and the patients. Black-blood coronary MR angiography provides an alternative source of contrast enhancement.
引用
收藏
页码:278 / 283
页数:6
相关论文
共 50 条
  • [1] Coronary artery anomalies: Assessment with free-breathing three-dimensional coronary MR angiogriaphy
    Bunce, NH
    Lorenz, CH
    Keegan, J
    Lesser, J
    Reyes, EM
    Firmin, DN
    Pennell, DJ
    RADIOLOGY, 2003, 227 (01) : 201 - 208
  • [2] Coronary MR angiography with steady-state free precession: Individually adapted breath-hold technique versus free-breathing technique
    Jahnke, C
    Paetsch, I
    Schnackenburg, B
    Bornstedt, A
    Gebker, R
    Fleck, E
    Nagel, E
    RADIOLOGY, 2004, 232 (03) : 669 - 676
  • [3] Free-breathing cardiac MR imaging:: Study of implications of respiratory motion-initial results
    Nehrke, K
    Börnert, P
    Manke, D
    Böck, JC
    RADIOLOGY, 2001, 220 (03) : 810 - 815
  • [4] Impact of navigator timing on free-breathing submillimeter 3D coronary magnetic resonance angiography
    Spuentrup, E
    Manning, WJ
    Botnar, RM
    Kissinger, KV
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (01) : 196 - 201
  • [5] Detection of coronary artery disease by free-breathing, whole heart coronary magnetic resonance angiography: our initial experience
    Kunimasa, Taeko
    Sato, Yuichi
    Matsumoto, Naoya
    Chiku, Masaaki
    Tani, Shigemasa
    Kasama, Shu
    Kunimoto, Satoshi
    Yoda, Shunichi
    Saito, Satoshi
    Nagao, Ken
    HEART AND VESSELS, 2009, 24 (06) : 429 - 433
  • [6] Detection of coronary artery disease by free-breathing, whole heart coronary magnetic resonance angiography: our initial experience
    Taeko Kunimasa
    Yuichi Sato
    Naoya Matsumoto
    Masaaki Chiku
    Shigemasa Tani
    Shu Kasama
    Satoshi Kunimoto
    Shunichi Yoda
    Satoshi Saito
    Ken Nagao
    Heart and Vessels, 2009, 24 : 429 - 433
  • [7] 2-DIMENSIONAL CORONARY MR-ANGIOGRAPHY - ANALYSIS OF INITIAL CLINICAL-RESULTS
    DUERINCKX, AJ
    URMAN, MK
    RADIOLOGY, 1994, 193 (03) : 731 - 738
  • [8] Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling:: Comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography -: Pilot study
    Spuentrup, E
    Katoh, M
    Buecker, A
    Manning, WJ
    Schaeffter, T
    Nguyen, TH
    Kühl, HP
    Stuber, M
    Botnar, RM
    Günther, RW
    RADIOLOGY, 2004, 231 (02) : 581 - 586
  • [9] Comparison of 3D free-breathing coronary MR angiography and 64-MDCT angiography for detection of coronary stenosis in patients with high calcium scores
    Liu, Xin
    Zhao, Xihai
    Huang, Jie
    Francois, Christopher J.
    Tuite, David
    Bi, Xiaoming
    Li, Debiao
    Carr, James C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) : 1326 - 1332
  • [10] MR coronary angiography with breath-hold targeted volumes: Preliminary clinical results
    van Geuns, RJM
    Wielopolski, PA
    de Bruin, HG
    Rensing, BJWM
    Hulshoff, M
    van Ooijen, PMA
    de Feyter, PJ
    Oudkerk, M
    RADIOLOGY, 2000, 217 (01) : 270 - 277