Energy efficiency versus indoor environmental quality in different Romanian countryside schools

被引:51
作者
Ghita, Stefan Alexandru [1 ]
Catalina, Tiberiu [2 ]
机构
[1] Delft Univ Technol, Fac Sci Appl, Delft, Netherlands
[2] Tech Univ Civil Engn Bucharest, Fac Bldg Serv & Equipment, Cambi Res Ctr, Bucharest, Romania
关键词
Indoor environmental quality; Educational facilities; Energy consumption; AIR-QUALITY; CLASSROOMS; IEQ; COMFORT; PERFORMANCE; ACCEPTANCE; BUILDINGS; OCCUPANTS; MODEL;
D O I
10.1016/j.enbuild.2015.01.049
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current research study, aims to couple the indoor environmental quality (IEQ) in countryside schools with energy efficiency. A detailed investigation took place on three different types of rural schools (old, new, and renovated) conveniently located for comparison purposes within a radius of 2.5 km from each other. The IEQ assessment covered the period autumn 2013-spring 2014 and included both long term measurements and spot recordings. In terms of indoor air quality all three buildings performed poorly, registering average CO2 concentrations in excess of 2000-3000 ppm and even approaching the health hazard level of 5000 ppm. Based on these concentrations, the corresponding ventilation rates have been calculated at 2.4 L/s/person (renovated school), 2.25 L/s/person (new school) and 0.7 L/s/person (old school). The IEQ index was calculated using the experimental data allowing the three analyzed schools to be better rated. The new and renovated buildings rank class Con the IEQ index scale and class A from an energy consumption standpoint, whereas the old building is rated D class (IEQ) and C class (energy efficiency). This shows that high energy consumption, as is the case for the old school, does not necessarily result in better comfort conditions despite their inverse correlation. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 154
页数:15
相关论文
共 42 条
  • [1] [Anonymous], 2008, BUILD REG
  • [2] [Anonymous], 2004, VENT ACC IND AIR QUA
  • [3] [Anonymous], 2007, 15251 EN
  • [4] ASHRAE, 2010, Ventilation for acceptable indoor Air quality
  • [5] Ventilation rates in schools and pupils' performance
    Bako-Biro, Zs.
    Clements-Croome, D. J.
    Kochhar, N.
    Awbi, H. B.
    Williams, M. J.
    [J]. BUILDING AND ENVIRONMENT, 2012, 48 : 215 - 223
  • [6] Modeling of occupant-generated CO2 dynamics in naturally ventilated classrooms
    Bartlett, KH
    Martinez, M
    Bert, J
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2004, 1 (03) : 139 - 148
  • [7] Improving energy performance of school buildings while ensuring indoor air quality ventilation
    Becker, Rachel
    Goldberger, Itamar
    Paciuk, Monica
    [J]. BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3261 - 3276
  • [8] Comfort of workers in office buildings: The European HOPE project
    Bluyssen, Philomena M.
    Aries, Myriam
    van Dommelen, Paula
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (01) : 280 - 288
  • [9] Development of a multivariate regression model for overall satisfaction in public buildings based on field studies in Beijing and Shanghai
    Cao, Bin
    Ouyang, Qin
    Zhu, Yingxin
    Huang, Li
    Hu, Hongbo
    Deng, Gaofeng
    [J]. BUILDING AND ENVIRONMENT, 2012, 47 : 394 - 399
  • [10] Indoor air quality in schools
    Cartieaux, E.
    Rzepka, M. -A.
    Cuny, D.
    [J]. ARCHIVES DE PEDIATRIE, 2011, 18 (07): : 789 - 796