New DIN and ISO norms for determination of visual acuity

被引:11
作者
Wesemann, W.
Heinrich, S. P. [1 ]
Jaegle, H. [2 ]
Schiefer, U. [3 ,4 ]
Bach, M. [1 ]
机构
[1] Albert Ludwigs Univ Freiburg, Klin Augenheilkunde, Univ Klinikum Freiburg, Med Fak, Freiburg, Germany
[2] Univ Augenklin, Regensburg, Germany
[3] Hsch Aalen, Studiengang Augenopt, Aalen, Germany
[4] Univ Tubingen, Dept Augenheilkunde, Tubingen, Germany
来源
OPHTHALMOLOGE | 2020年 / 117卷 / 01期
关键词
Visual acuity; Decimal visual acuity; LogMAR; Snellen fraction; Crowding;
D O I
10.1007/s00347-019-0943-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Recently, three international norms (ISO) for visual acuity assessment were revised. The DIN EN ISO 8596:2018 stipulates the Landolt C eye chart as the standard optotype and specifies display characteristics. An informative annex lists clinical optotypes for the first time. These include the ETDRS chart, Snellen chart and pediatric optotypes; however, these clinical optotypes do not have the same status as the Landolt C chart, since even with identical font size and stroke width they may differ in recognizability. The technical report ISO/TR 19498:2015 complements DIN EN ISO 8596. A scientifically appropriate procedure is described, which enables a quantitative correlation of clinical optotypes with the Landolt C chart. The DIN EN ISO 10938:2016 describes the required optical quality of optotypes. For the first time, electronic devices are explicitly approved for standardized visual acuity tests. Consequently, according to this amendment electronic devices may be used for acuity assessment for ophthalmological expert opinions according to DIN 58220, part 3.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [21] Acuity norms of infants by clinical application of Teller Acuity Cards
    Grunewald, SM
    Mayer, UM
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1997, 210 (06) : 376 - 383
  • [22] A comparison of visual acuity measured by ETDRS chart and Standard Logarithmic Visual Acuity chart among outpatients
    Wang, Tao
    Huang, Pei-Jie
    Chen, Chen
    Liu, Ding-Wei
    Yi, Jing-Lin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (04) : 536 - 540
  • [23] A New Method for Assessing Central and Peripheral Visual Acuity
    Yong-Wan, Lee
    Jong-Mo, Seo
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 275 - +
  • [24] The Freiburg Visual Acuity test - Automatic measurement of visual acuity
    Bach, M
    OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) : 49 - 53
  • [25] Visual Acuity Examination Methodology in Keratoconus
    Nandzik, Magdalena
    Wylegala, Edward
    Wylegala, Adam
    Szkodny, Dominika
    Roszkowska, Anna Maria
    Wroblewska-Czajka, Ewa
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [26] A need for standardization in visual acuity measurement
    Patel, Hina
    Congdon, Nathan
    Strauss, Glenn
    Lansingh, Charles
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (05) : 332 - 337
  • [27] A New Visual Stimulation Program for Improving Visual Acuity in Children with Visual Impairment: A Pilot Study
    Tsai, Li-Ting
    Hsu, Jung-Lung
    Wu, Chien-Te
    Chen, Chia-Ching
    Su, Yu-Chin
    FRONTIERS IN HUMAN NEUROSCIENCE, 2016, 10
  • [28] Diagnosing Cerebral Visual Impairment in Children with Good Visual Acuity
    van Genderen, Maria
    Dekker, Marjoke
    Pilon, Florine
    Bals, Irmgard
    STRABISMUS, 2012, 20 (02) : 78 - 83
  • [29] Visual Acuity Testing Using a Random Method Visual Acuity Application
    Rhiu, Soolienah
    Lee, Hye Jin
    Goo, Yong Sook
    Cho, Kyoungrok
    Kim, Jae-hyung
    TELEMEDICINE AND E-HEALTH, 2016, 22 (03) : 232 - 237
  • [30] Contribution of sVEP visual acuity testing in comparison with subjective visual acuity
    Vesely, Petr
    BIOMEDICAL PAPERS-OLOMOUC, 2015, 159 (04): : 616 - 621