New DIN and ISO norms for determination of visual acuity

被引:11
|
作者
Wesemann, W.
Heinrich, S. P. [1 ]
Jaegle, H. [2 ]
Schiefer, U. [3 ,4 ]
Bach, M. [1 ]
机构
[1] Albert Ludwigs Univ Freiburg, Klin Augenheilkunde, Univ Klinikum Freiburg, Med Fak, Freiburg, Germany
[2] Univ Augenklin, Regensburg, Germany
[3] Hsch Aalen, Studiengang Augenopt, Aalen, Germany
[4] Univ Tubingen, Dept Augenheilkunde, Tubingen, Germany
来源
OPHTHALMOLOGE | 2020年 / 117卷 / 01期
关键词
Visual acuity; Decimal visual acuity; LogMAR; Snellen fraction; Crowding;
D O I
10.1007/s00347-019-0943-x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Recently, three international norms (ISO) for visual acuity assessment were revised. The DIN EN ISO 8596:2018 stipulates the Landolt C eye chart as the standard optotype and specifies display characteristics. An informative annex lists clinical optotypes for the first time. These include the ETDRS chart, Snellen chart and pediatric optotypes; however, these clinical optotypes do not have the same status as the Landolt C chart, since even with identical font size and stroke width they may differ in recognizability. The technical report ISO/TR 19498:2015 complements DIN EN ISO 8596. A scientifically appropriate procedure is described, which enables a quantitative correlation of clinical optotypes with the Landolt C chart. The DIN EN ISO 10938:2016 describes the required optical quality of optotypes. For the first time, electronic devices are explicitly approved for standardized visual acuity tests. Consequently, according to this amendment electronic devices may be used for acuity assessment for ophthalmological expert opinions according to DIN 58220, part 3.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [1] Neue DIN- und ISO-Normen zur SehschärfebestimmungNew DIN and ISO norms for determination of visual acuity
    W. Wesemann
    S. P. Heinrich
    H. Jägle
    U. Schiefer
    M. Bach
    Der Ophthalmologe, 2020, 117 : 19 - 26
  • [2] New DIN norms for determination of visual acuity
    Wesemann, W.
    Schiefer, U.
    Bach, M.
    OPHTHALMOLOGE, 2010, 107 (09): : 821 - 826
  • [3] Neue DIN-Normen zur SehschärfebestimmungNew DIN norms for determination of visual acuity
    W. Wesemann
    U. Schiefer
    M. Bach
    Der Ophthalmologe, 2010, 107 : 821 - 826
  • [4] Differential visual acuity - A new approach to measuring visual acuity
    Leat, Susan J.
    Yakobchuk-Stanger, Cristina
    Irving, Elizabeth L.
    JOURNAL OF OPTOMETRY, 2020, 13 (01) : 41 - 49
  • [5] A new Arabic distance visual acuity chart
    AlMufarrej, MM
    AboHiemed, FA
    Oduntan, AO
    OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) : 59 - 61
  • [6] Calculating the mean visual acuity and the change in visual acuity with a decimal acuity chart
    Touzeau, O
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2003, 26 (06): : 586 - 590
  • [7] Mesopic visual acuity is less crowded
    František Pluháček
    John Siderov
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2018, 256 : 1739 - 1746
  • [8] Mesopic visual acuity is less crowded
    Pluhacek, Frantisek
    Siderov, John
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 256 (09) : 1739 - 1746
  • [9] A new source of variance in visual acuity
    Coppens, JE
    van den Berg, TJTP
    VISION RESEARCH, 2004, 44 (09) : 951 - 958
  • [10] New optotypes for checking visual acuity
    Milanich, A. I.
    MEASUREMENT TECHNIQUES, 2008, 51 (08) : 865 - 867