Flow-Injection Potentiometric Method for the Routine Determination of Chloride: Application to Bread Analysis

被引:0
作者
Almeida, Sofia A. A. [1 ,2 ]
Rebelo, Tania S. C. R. [2 ]
Heitor, Ana M. [2 ]
Oliveira, M. Beatriz P. P. [3 ]
Sales, M. Goreti F. [1 ]
机构
[1] Inst Super Engn Porto, Dept Chem Engn, REQUIMTE, P-4200072 Oporto, Portugal
[2] INSA, P-4000055 Oporto, Portugal
[3] Fac Farm, Serv Bromatol, REQUIMTE, P-4050047 Oporto, Portugal
关键词
Chloride; Ion selective electrode; Bread; Flow-injection analysis; Food; ION-SELECTIVE ELECTRODES; SOLID-PHASE REACTOR; SEQUENTIAL INJECTION; SPECTROPHOTOMETRIC DETERMINATION; TURBIDIMETRIC DETERMINATION; SYSTEM; WATER; TITRATION; RESIN; ARRAY;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bread is consumed worldwide by man, thus contributing to the regular ingestion of certain inorganic species such as chloride. It controls the blood pressure if associated to a sodium intake and may increase the incidence of stomach ulcer. Its routine control should thus be established by means of quick and low cost procedures. This work reports a double-channel flow injection analysis (FIA) system with a new chloride sensor for the analysis of bread. All solutions are prepared in water and necessary ionic strength adjustments are made on-line. The body of the indicating electrode is made from a silver needle of 0.8 mm i.d. with an external layer of silver chloride. These devices were constructed with different lengths. Electrodes of 1.0 to 3.0 cm presented better analytical performance. The calibration curves under optimum conditions displayed Nernstian behaviour, with average slopes of 56 mV decade(-1), with sampling rates of 60 samples h(-1). The method was applied to analyze several kinds of bread, namely pao de trigo, pao integral, pao de centeio, pao de mistura, broa de milho, pao sem sal, pao meio sal, pao-de-leite, and pao de agua. The accuracy and precision of the potentiometric method were ascertained by comparison to a spectrophotometric method of continuous segmented flow. These methods were validated against ion-chromatography procedures.
引用
收藏
页码:277 / 287
页数:11
相关论文
共 40 条
[1]   Ion chromatographic determination of some organic acids, chloride and phosphate in coffee and tea [J].
Alcázar, A ;
Fernández-Cáceres, PL ;
Martín, MJ ;
Pablos, F ;
González, AG .
TALANTA, 2003, 61 (02) :95-101
[2]  
Alexander PW, 1998, ELECTROANAL, V10, P707, DOI 10.1002/(SICI)1521-4109(199808)10:10<707::AID-ELAN707>3.3.CO
[3]  
2-M
[4]   FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF CHLORIDE WITH AN ONLINE SOLID MERCURY(II) THIOCYANATE MINICOLUMN AND BROMIDE WITH A SILVER THIOCYANATE MINICOLUMN [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1991, 245 (01) :115-119
[5]   Determination of chloride by multisyringe flow injection analysis and sequential injection analysis with potentiometric detection [J].
Andrade-Eiroa, A ;
Erustes, JA ;
Forteza, R ;
Cerdá, V ;
Lima, JLFC .
ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) :25-33
[6]   DELETERIOUS EFFECTS OF SALT INTAKE OTHER THAN EFFECTS ON BLOOD-PRESSURE [J].
ANTONIOS, TFT ;
MACGREGOR, GA .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1995, 22 (03) :180-184
[7]   An improved flow system for chloride determination in natural waters exploiting solid-phase reactor and long pathlength spectrophotometry [J].
Bonifacio, Viviane G. ;
Figueiredo-Filho, Luiz C. ;
Marcolino, Luiz H., Jr. ;
Fatibello-Filho, Orlando .
TALANTA, 2007, 72 (02) :663-667
[8]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[9]   RECOMMENDED PROCEDURES FOR CALIBRATION OF ION-SELECTIVE ELECTRODES [J].
BUCK, RP ;
COSOFRET, VV .
PURE AND APPLIED CHEMISTRY, 1993, 65 (08) :1849-1858
[10]   FLOW-INJECTION ANALYSIS WITH ELECTROCHEMICAL DETECTION [J].
CAMMANN, K .