Full-scale burn tests of wooden three-story apartment building

被引:0
|
作者
Hayashi, Y [1 ]
Hasemi, Y [1 ]
Nakamura, K [1 ]
Hokugo, A [1 ]
Hagiwara, I [1 ]
Motegi, T [1 ]
Yamana, T [1 ]
Yoshida, M [1 ]
Goto, T [1 ]
Wakamatsu, T [1 ]
Sugawa, O [1 ]
Ohmiya, Y [1 ]
Akabane, N [1 ]
Abe, I [1 ]
Izumi, J [1 ]
Fukumoto, M [1 ]
Saito, H [1 ]
机构
[1] Bldg Res Inst, Ibaraki, Osaka, Japan
关键词
wooden three-story apartment building; full-scale burn test; fire spread; city fire;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A full-scale fire experiment was conducted for the assessment of fire safety of a wooden three-story apartment buildings in a city fire scenario. A city fire was simulated with n-heptane pools and propane porous burners. A full scale three-story apartment building with two apartment units on each floor was exposed to this flame. Measurements were made to evaluate fire spread from the city fire to the wooden three-story apartment building, fire spread within the wooden three-story apartment building and fire spread from the wooden three-story apartment building to adjacent buildings.
引用
收藏
页码:100 / 126
页数:27
相关论文
共 50 条
  • [1] DYNAMIC CHARACTERIZATION OF A FULL-SCALE THREE-STORY MASS TIMBER BUILDING STRUCTURE
    Uarac, Patricio A. P.
    Barbosa, Andre R.
    Sinha, Arijit
    Simpson, Barbara G.
    Ho, Tu X.
    XII INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2023, 2024, 2647
  • [2] Shaking Table Testing of a Full-Scale Prefabricated Three-Story Timber-Frame Building
    Tomasi, Roberto
    Sartori, Tiziano
    Casagrande, Daniele
    Piazza, Maurizio
    JOURNAL OF EARTHQUAKE ENGINEERING, 2015, 19 (03) : 505 - 534
  • [3] Full-scale validation of CFD simulations of buoyancy-driven ventilation in a three-story office building
    Chen, Chen
    Gorle, Catherine
    BUILDING AND ENVIRONMENT, 2022, 221
  • [4] Shake-Table Tests of a Full-Scale Three-Story Reinforced Masonry Shear Wall Structure
    Stavridis, A.
    Ahmadi, F.
    Mavros, M.
    Shing, P. B.
    Klingner, R. E.
    McLean, D.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (10)
  • [5] The test of a full-scale three-story RC structure with masonry infill walls
    Pujol, S.
    Fick, D.
    ENGINEERING STRUCTURES, 2010, 32 (10) : 3112 - 3121
  • [6] Full-Scale Blast Tests on a Conventionally Designed Three-Story Steel Braced Frame with Composite Floor Slabs
    Hadjioannou, Michalis
    McKay, Aldo E.
    Benshoof, Phillip C.
    VIBRATION, 2021, 4 (04): : 865 - 892
  • [7] Building characterization and aerosol infiltration into a naturally ventilated three-story apartment building
    Rodes, Charles E.
    VanOsdell, Douglas W.
    Portzer, Jeffrey W.
    Seagraves, Jeremy
    Hahn, Intaek
    Henkle, Stacy W.
    Wiener, Russell W.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2009, 11 (12): : 2180 - 2191
  • [8] Full-scale shake table tests of P&B type of Japanese three-story wood dwellings for the collapse characterization
    Yenidogan, Cem
    Nishi, Ryota
    Uwadan, Seiya
    Nagae, Takuya
    Isoda, Hiroshi
    Tsuchimoto, Takahiro
    Inoue, Takahiro
    Kajiwara, Koichi
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 150
  • [9] Seismic Design and Hybrid Tests of a Full-Scale Three-Story Concentrically Braced Frame Using In-Plane Buckling Braces
    Tsai, Ching-Yi
    Tsai, Keh-Chyuan
    Lin, Pao-Chun
    Ao, Wai-Hang
    Roeder, Charles W.
    Mahin, Stephen A.
    Lin, Chih-Han
    Yu, Yi-Jer
    Wang, Kung-Juin
    Wu, An-Chien
    Chen, Jia-Chian
    Lin, Te-Hung
    EARTHQUAKE SPECTRA, 2013, 29 (03) : 1043 - 1067
  • [10] Damage assessment by stiffness identification for a full-scale three-story steel moment resisting frame building subjected to a sequence of earthquake excitations
    Zhou, Cong
    Chase, J. Geoffrey
    Rodgers, Geoffrey W.
    Iihoshi, Chikara
    BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (12) : 5393 - 5412