CdTe and CdZnTe room-temperature X-ray and gamma ray detectors and imaging systems

被引:13
|
作者
Eisen, Y [1 ]
Shor, A [1 ]
机构
[1] Soreq NRC, IL-81800 Yavne, Israel
关键词
D O I
10.1557/PROC-487-129
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CdTe and CdZnTe X-ray and gamma ray detectors in the form of single elements or as monolithic segmented arrays have been shown to be useful in imaging systems utilized in medical, research or industrial applications. These detectors possess inherently better energy resolution than scintillators coupled to either photodiodes or photomultipliers, and they may lead to compact imaging systems or to imaging systems of enhanced spatial resolution and better contrast resolution. Photopeak efficiencies of these detectors is greatly affected by relatively low hole mobility-lifetime product and therefore continuing efforts are still underway to improve the characteristics of both CdTe and CdZnTe materials in order to achieve reproducible detectors with higher photopeak efficiencies for either low or high energy gamma rays. The following paper is divided into three parts: The first part compares the characteristics of planar CdTe and CdZnTe single elements nuclear detectors containing metal contacts. Characteristics include: Charge collection efficiencies for both electrons and holes indicated by the mobility-lifetime product, energy resolutions, leakage currents and robustness in field use. The second part describes excellent spectroscopic results using a 1cm thick CdZnTe monolithic segmented pad detector array. This part also compares spectra for various gamma energies obtained by this segmented detector to that of a 1cm(3) detector acting as a single element planar detector. The third part discusses the characteristics of a new generation nuclear gamma camera for medical diagnostics based on room-temperature CdTe and CdZnTe spectrometers and its advantages over an Anger type scintillating nuclear camera.
引用
收藏
页码:129 / 145
页数:17
相关论文
共 50 条
  • [41] Impact of sub-pixelation within CdZnTe detectors for X-ray diffraction imaging systems
    Tabary, J.
    Paulus, C.
    Montemont, G.
    Verger, L.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) II, 2017, 10187
  • [42] Fast CdTe and CdZnTe Semiconductor Detector Arrays for Spectroscopic X-Ray Imaging
    Brambilla, Andrea
    Ouvrier-Buffet, P.
    Gonon, G.
    Rinkel, J.
    Moulin, V.
    Boudou, C.
    Verger, L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 408 - 415
  • [43] Study of Surface Passivation and Contact Deposition Techniques in CdZnTe X-Ray and Gamma-Ray Detectors
    Jones, Dominique E.
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Drabo, Mebougna L.
    Hall, JaQueeta
    Adams, Aaron L.
    Babalola, Stephen O.
    Camarda, Giuseppe S.
    Bolotnikov, Aleksey E.
    Chan, Wing
    James, Ralph B.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4124 - 4127
  • [44] Organic room-temperature phosphorescent polymers for efficient X-ray scintillation and imaging
    Juan Wei
    Yangyang Jiang
    Chenyuan Liu
    Jiayu Duan
    Shanying Liu
    Xiangmei Liu
    Shujuan Liu
    Yun Ma
    Qiang Zhao
    Advanced Photonics, 2022, 4 (03) : 94 - 100
  • [45] Organic room-temperature phosphorescent polymers for efficient X-ray scintillation and imaging
    Wei, Juan
    Jiang, Yangyang
    Liu, Chenyuan
    Duan, Jiayu
    Liu, Shanying
    Liu, Xiangmei
    Liu, Shujuan
    Ma, Yun
    Zhao, Qiang
    ADVANCED PHOTONICS, 2022, 4 (03):
  • [46] Low noise gamma-ray and X-ray detectors based on CdTe-materials
    Abro, E
    Johansen, GA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 470 - 474
  • [47] Cdznte technology for gamma ray detectors
    Stahle, C
    Shi, J
    Shu, P
    Barthelmy, S
    Parsons, A
    Snodgrass, S
    SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM - 1998, PTS 1-3: 1ST CONF ON GLOBAL VIRTUAL PRESENCE; 1ST CONF ON ORBITAL TRANSFER VEHICLES; 2ND CONF ON APPLICAT OF THERMOPHYS IN MICROGRAV; 3RD CONF ON COMMERCIAL DEV OF SPACE; 3RD CONF ON NEXT GENERAT LAUNCH SYST; 15TH SYMP ON SPACE NUCL POWER AND PROPULSION, 1998, (420): : 55 - 60
  • [48] A Room-Temperature X-ray-Induced Photochromic Material for X-ray Detection
    Wang, Ming-Sheng
    Yang, Chen
    Wang, Guan-E
    Xu, Gang
    Lv, Xiang-Ying
    Xu, Zhong-Ning
    Lin, Rong-Guang
    Cai, Li-Zhen
    Guo, Guo-Cong
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (14) : 3432 - 3435
  • [49] BiI3 single crystal for room-temperature gamma ray detectors
    Saito, T.
    Iwasaki, T.
    Kurosawa, S.
    Yoshikawa, A.
    Den, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 395 - 400
  • [50] ADVANTAGES AND LIMITATIONS OF CADMIUM SELENIDE ROOM-TEMPERATURE GAMMA-RAY DETECTORS
    ROTH, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (02): : 291 - 298