CdTe and CdZnTe room-temperature X-ray and gamma ray detectors and imaging systems

被引:13
|
作者
Eisen, Y [1 ]
Shor, A [1 ]
机构
[1] Soreq NRC, IL-81800 Yavne, Israel
关键词
D O I
10.1557/PROC-487-129
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CdTe and CdZnTe X-ray and gamma ray detectors in the form of single elements or as monolithic segmented arrays have been shown to be useful in imaging systems utilized in medical, research or industrial applications. These detectors possess inherently better energy resolution than scintillators coupled to either photodiodes or photomultipliers, and they may lead to compact imaging systems or to imaging systems of enhanced spatial resolution and better contrast resolution. Photopeak efficiencies of these detectors is greatly affected by relatively low hole mobility-lifetime product and therefore continuing efforts are still underway to improve the characteristics of both CdTe and CdZnTe materials in order to achieve reproducible detectors with higher photopeak efficiencies for either low or high energy gamma rays. The following paper is divided into three parts: The first part compares the characteristics of planar CdTe and CdZnTe single elements nuclear detectors containing metal contacts. Characteristics include: Charge collection efficiencies for both electrons and holes indicated by the mobility-lifetime product, energy resolutions, leakage currents and robustness in field use. The second part describes excellent spectroscopic results using a 1cm thick CdZnTe monolithic segmented pad detector array. This part also compares spectra for various gamma energies obtained by this segmented detector to that of a 1cm(3) detector acting as a single element planar detector. The third part discusses the characteristics of a new generation nuclear gamma camera for medical diagnostics based on room-temperature CdTe and CdZnTe spectrometers and its advantages over an Anger type scintillating nuclear camera.
引用
收藏
页码:129 / 145
页数:17
相关论文
共 50 条
  • [21] X-Ray Spectroscopy with a Room Temperature CdZnTe Detector
    Fritz, S. G.
    Shikhaliev, P. M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [22] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    Stahle, CM
    Parker, BH
    Parsons, AM
    Barbier, LM
    Barthelmy, SD
    Gehrels, NA
    Palmer, DM
    Snodgrass, SJ
    Tueller, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 138 - 145
  • [23] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    NASA Goddard Space Flight Center, Greenbelt, MD 20771, United States
    不详
    不详
    Nucl Instrum Methods Phys Res Sect A, 1-2 (138-145):
  • [24] X ray and gamma ray spectroscopy with segmented CdZnTe detectors
    Shor, A
    Eisen, Y
    Mardor, I
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 : 59 - 70
  • [25] Screening effects in high resistivity CdTe for X-ray and gamma ray detectors
    Kubat, J.
    Franc, J.
    Grill, R.
    Horodysky, P.
    Hlidek, P.
    Belas, E.
    JOURNAL OF ELECTRONIC MATERIALS, 2007, 36 (08) : 871 - 876
  • [26] Screening Effects in High Resistivity CdTe for X-ray and Gamma Ray Detectors
    J. Kubát
    J. Franc
    R. Grill
    P. Horodyský
    P. Hlídek
    E. Belas
    Journal of Electronic Materials, 2007, 36 : 871 - 876
  • [27] New trends in CdTe and CdZnTe detectors for X- and gamma-ray applications
    Limousin, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 24 - 37
  • [28] Heavy metal ternary halides for room-temperature x-ray and gamma-ray detection
    Liu, Zhifu
    Peters, John A.
    Stoumpos, Constantinos C.
    Sebastian, Maria
    Wessels, Bruce W.
    Im, Jino
    Freeman, Arthur J.
    Kanatzidis, Mercouri G.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [29] New developments in CdTe and CdZnTe detectors for X and γ-ray applications
    L. Verger
    J. P. Bonnefoy
    F. Glasser
    P. Ouvrier-Buffet
    Journal of Electronic Materials, 1997, 26 : 738 - 744
  • [30] The X-ray response of CdZnTe detectors to be used as future spectroscopic detectors for X-ray astronomy
    Kraft, S
    Bavdaz, M
    Castelletto, B
    Peacock, A
    Scholze, F
    Ulm, G
    Gagliardi, MA
    Nenonen, S
    Tuomi, T
    Juvonen, M
    Rantamaki, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 337 - 347