99mTc DTPA vs. 51Cr EDTA for glomerular filtration rate measurement: is there a systematic difference?

被引:12
|
作者
McMeekin, Helena [1 ]
Barnfield, Mark [2 ]
Wickham, Fred [3 ]
Burniston, Maria [1 ]
机构
[1] Barts Hlth NHS Trust, Dept Nucl Med, London, England
[2] St James Univ Hosp, Dept Nucl Med, Leeds, W Yorkshire, England
[3] Royal Free London NHS Fdn Trust, Dept Nucl Med, London, England
关键词
Cr-51; EDTA; Tc-99m DTPA; glomerular filtration rate; isotope glomerular filtration rate; CLEARANCE; ACID;
D O I
10.1097/MNM.0000000000001101
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim The study aimed to investigate whether a systematic difference exists between Cr-51 EDTA and Tc-99m DTPA for measurement of glomerular filtration rate (GFR). Methods The distribution of GFR results from candidates attending the Royal Free Hospital for assessment of suitability for kidney donation was compared before and after the change from Cr-51 EDTA to Tc-99m DTPA using three-sample slope-intercept GFR calculation with samples at 2, 3, and 4 hours. A second cohort of oncology patients attending Leeds Teaching Hospitals NHS Trust underwent simultaneous GFR measurement with both tracers by full characterisation of the plasma clearance curve with nine samples between 5 minutes and 8 hours post-injection. Three-sample slope-intercept GFR was also calculated for comparison with cohort 1. Results From the first cohort, a statistically significant (P= 0.008) systematic difference of 5.8% (95% confidence interval: 1.5%-10.1%) was found in the three-sample slope-intercept GFR, with Tc-99m DTPA giving the higher result. From the second cohort, a statistically significant (P= 0.00001) systematic difference of 2.9% (95% confidence interval: 1.8%-3.9%) was found in three-sample slope-intercept GFR, with Tc-99m DTPA giving the higher result. There was no statistically significant difference between the tracers when GFR was calculated by full characterisation of the plasma clearance curve. Conclusion There is a small systematic difference between GFR measured with Tc-99m DTPA and Cr-51 EDTA using abbreviated techniques, which is removed when GFR is calculated by full characterisation of the plasma clearance curve. The difference is not clinically significant in the context of intra-patient variability of GFR measurement. Copyright (C) 2019 Wolters Kluwer Health. Inc. All rights reserved.
引用
收藏
页码:1224 / 1229
页数:6
相关论文
共 50 条
  • [1] Glomerular filtration rate: comparison of simultaneous plasma clearance of 99mTc-DTPA and 51Cr-EDTA revisited
    Simonsen, Jane A.
    Thilsing-Hansen, Kasper
    Hoilund-Carlsen, Poul F.
    Gerke, Oke
    Andersen, Thomas L.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (05): : 408 - 411
  • [2] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method
    Balouzet, Clara
    Michon-Colin, Arthur
    Dupont, Lea
    Vidal-Petiot, Emmanuelle
    Prot-Bertoye, Caroline
    Baron, Stephanie
    Ayari, Hamza
    Cohen, Raphal
    Houillier, Pascal
    Smadja, Corinne
    Flamant, Martin
    Courbebaisse, Marie
    JOURNAL OF NEPHROLOGY, 2023, 36 (09) : 2457 - 2465
  • [3] Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method
    Clara Balouzet
    Arthur Michon-Colin
    Léa Dupont
    Emmanuelle Vidal-Petiot
    Caroline Prot-Bertoye
    Stéphanie Baron
    Hamza Ayari
    Raphaël Cohen
    Pascal Houillier
    Corinne Smadja
    Martin Flamant
    Marie Courbebaisse
    Journal of Nephrology, 2023, 36 : 2457 - 2465
  • [4] Comparison of glomerular filtration rate estimation by 99mTc-DTPA to the reference radiotracer 51Cr-EDTA compared to methods based on blood creatinine measurement
    Saleh, N. S.
    Marie, S.
    Grimon, G.
    Durand, E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2021, 45 (03): : 142 - 146
  • [5] Comparison of 51Cr-EDTA with 99mTc-DTPA slope clearance for estimation of glomerular filtration rate using the one-compartment model
    Chapot, C
    Seifert, H
    Samnick, S
    Kirsch, CM
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 1998, 37 (04): : 124 - 128
  • [6] Determination of the glomerular filtration rate in patients with type 2 diabetes: An assessment of the agreement between 51Cr-EDTA plasma clearance and 99mTc-DTPA plasma clearance, 99mTc-DTPA renography and plasma creatinine prediction equation
    Moralidis, Efstratios
    Papanastasiou, Emmanouil
    Didangelos, Triantafyllos
    Hilidis, Ilias
    Siountas, Anastasios
    Arsos, Georgios
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2020, 161
  • [7] A comparison of the plasma disappearance of iohexol and 99mTc-DTPA for the measurement of glomerular filtration rate (GFR) in diabetes
    Houlihan, C
    Scott, A
    Jenkins, M
    Parkin, D
    Osicka, T
    Jerums, G
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1999, 29 (05): : 693 - 700
  • [8] Accuracy of plasma sample methods for determination of glomerular filtration rate with99mTc-DTPA
    Kazuo Itoh
    Satoshi Tsushima
    Eriko Tsukamoto
    Nagara Tamaki
    Annals of Nuclear Medicine, 2002, 16 : 39 - 44
  • [9] Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA
    Itoh, K
    Tsushima, S
    Tsukamoto, E
    Tamaki, N
    ANNALS OF NUCLEAR MEDICINE, 2002, 16 (01) : 39 - 44
  • [10] Reference ranges for 51Cr-EDTA measurements of glomerular filtration rate in children
    Blake, GM
    Gardiner, N
    Gnanasegaran, G
    Dizdarevic, S
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (11) : 983 - 987