Respirable dust concentrations in equine stables. Part 1: Validation of equipment and effect of various management systems

被引:48
作者
Clements, J. M. [1 ]
Pirie, R. S. [1 ]
机构
[1] Univ Edinburgh, Sch Vet Studies, Div Vet Clin Studies, Easter Bush Vet Ctr, Edinburgh EH25 9RG, Midlothian, Scotland
关键词
horse; recurrent airway obstruction; environment; respirable dust concentration; dust sampler; air quality;
D O I
10.1016/j.rvsc.2006.12.002
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Traditional methods of measuring airborne dust concentrations (ADC) in animal housing have included the collection of dust onto pre-weighed filters permitting the calculation of mean, not maximum, ADC. However real-time continuous particle monitors are advantageous in identifying short duration elevations in ADC which may be detrimental to equine respiratory health in the face of a relatively low mean ADC. These monitors have not previously been used to measure ADC in equine stables. Comparisons of a filter-based sampler and a real-time continuous particle monitor revealed no significant difference (P = 0.079) and good agreement (>= 95% of the points fell within two standard deviations of the mean of the differences and the mean of the differences approximated zero) between the devices, with respect to mean respirable dust concentration (RDC) measurements. Investigations of the influence of various equine management systems on RDC revealed that both mean and maximum breathing zone RDC were significantly reduced (P < 0.05) in equine stables by changing the environment from hay feed and straw bedding, to haylage feed and wood shavings bedding (reduction in mean -0.0867 mg/ In 3 to 0.0260 mg/m(3); reduction in maximum -4.0758 mg/m(3) to 0.2182 mg/m(3), respectively). (C)2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:256 / 262
页数:7
相关论文
共 22 条
[1]  
Art T., 2002, EQUINE RESP DIS
[2]  
BARTZ J, 1993, P 4 INT S AM SOC AGR, V4, P742
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
CAMPBELL MJ, 1994, STAT CONFIDENCE CONF, P71
[5]   Comparison of real-time instruments used to monitor airborne particulate matter [J].
Chung, A ;
Chang, DPY ;
Kleeman, MJ ;
Perry, KD ;
Cahill, TA ;
Dutcher, D ;
McDougall, EM ;
Stroud, K .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (01) :109-120
[6]  
CLARKE AF, 1987, IRISH VET J, V41, P258
[7]   DUST LEVELS IN A RIDING STABLE [J].
CRICHLOW, EC ;
YOSHIDA, K ;
WALLACE, K .
EQUINE VETERINARY JOURNAL, 1980, 12 (04) :185-188
[8]   MICROPOLYSPORA-FAENI CAUSES AIRWAY INFLAMMATION BUT NOT HYPERRESPONSIVENESS IN SENSITIZED PONIES [J].
DERKSEN, FJ ;
SCOTT, JS ;
SLOCOMBE, RF ;
ROBINSON, NE .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (04) :1398-1404
[9]  
DERKSEN FJ, 1994, EQUINE PRACT, V16, P11
[10]  
Dunlea AP, 1996, CAN AGR ENG, V38, P215