RESIDUAL STRESS MEASUREMENT BY NEUTRON DIFFRACTION IN A SINGLE BEAD ON PLATE WELD - INFLUENCE OF INSTRUMENT AND MEASUREMENT SETTINGS ON THE SCATTER OF THE RESULTS

被引:0
作者
Ohms, Carsten [1 ]
Wimpory, Robert [2 ]
Neov, Dimitar [3 ]
机构
[1] European Commiss, Joint Res Ctr, Inst Energy, Westerduinweg 3, NL-1755 LE Petten, Netherlands
[2] Helmholtz Zentrum Berlin Mat & Energie, D-14109 Berlin, Germany
[3] Inst Nucl Energy Res, Sofia 1784, Bulgaria
来源
THERMEC 2009, PTS 1-4 | 2010年 / 638-642卷
关键词
Single bead on plate weld; residual stress measurement; neutron diffraction; data scatter; rocking of the specimen; measurement duration; measurement resolution;
D O I
10.4028/www.scientific.net/MSF.638-642.2452
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Residual stress measurements on a single bead weld on a steel plate had been performed at the High Flux Reactor of the Joint Research Centre in 2003. For these measurements a relatively old diffractometer had been used. The results obtained were characterized by significant scatter of the data, and the measurement quality suffered from the short movement ranges of the specimen positioning table as well. In 2008, a second, nominally identical, specimen from the same activity was investigated on a second diffractometer, which allowed the repetition of the residual stress measurements using different measurement settings. The present paper compares the old and the new measurement results, with a view to assessing the impact of the instrumental settings on their quality. It has been found that the overall stress distributions from the 2003 and the 2008 measurements were in fact very similar Nevertheless, the new settings used, such as in-situ specimen rocking, extended measurement duration, increased density of measurement positions and spatial resolution among others, have been found to have considerable impact on the real and on the apparent scatter of the experimental results showing that the presented methodologies can be used for improvement of neutron diffraction measurements.
引用
收藏
页码:2452 / +
页数:2
相关论文
共 8 条
[1]  
*DD CEN ISO TS, 1996, 214322005 DD CEN ISO
[2]  
EDWARDS L, 2003, PROTOCOL EXPT VALIDA
[3]   X-ray investigation of stress states in materials .3. [J].
Eigenmann, B ;
Macherauch, E .
MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 1996, 27 (09) :426-437
[4]  
Hutchings MT., 2005, INTRO CHARACTERIZATI
[5]   NET TG1: Residual stress assessment by neutron diffraction and finite element modeling on a single bead weld on a steel plate [J].
Ohms, C. ;
Wimpory, R. C. ;
Katsareas, D. E. ;
Youtsos, A. G. .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2009, 86 (01) :63-72
[6]  
WASMUTH RC, 2009, EFFECT GRAIN SIZE ST
[7]   Statistical analysis of residual stress determinations using neutron diffraction [J].
Wimpory, R. C. ;
Ohms, C. ;
Hofmann, M. ;
Schneider, R. ;
Youtsos, A. G. .
INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2009, 86 (01) :48-62
[8]  
2009, INT J PRESSURE VESSE, V86