The Need for Standardization of Tacrolimus Assays

被引:49
作者
Levine, Daniel M. [1 ]
Maine, Gregory T. [2 ]
Armbruster, David A. [2 ]
Mussell, Christopher [3 ]
Buchholz, Christoph [3 ]
O'Connor, Gavin [3 ]
Tuck, Victoria [4 ]
Johnston, Atholl [4 ]
Holt, David W. [4 ]
机构
[1] Rogosin Inst, New York, NY 10065 USA
[2] Abbott Diagnost, Abbott Pk, IL USA
[3] LGC Ltd, Chem Measurement & Calibrat, Teddington, Middx, England
[4] St Georges Univ London, Analyt Serv Int Ltd, London, England
关键词
TRANSPLANTATION; IMMUNOASSAY; DRUGS;
D O I
10.1373/clinchem.2011.172080
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Owing to the lack of an internationally recognized tacrolimus reference material and reference method, current LC-MS and immunoassay test methods used to monitor tacrolimus concentrations in whole blood are not standardized. The aim of this study was to assess the need for tacrolimus assay standardization. METHODS: We sent a blinded 40-member whole-blood tacrolimus proficiency panel (0-30 mu g/L) to 22 clinical laboratories in 14 countries to be tested by the following assays: Abbott ARCHITECT (n = 17), LC-MS (n = 9), and Siemens Dade Dimension (n = 5). Selected LC-MS laboratories (n = 4) also received a common calibrator set. We compared test results to a validated LC-MS method. Four samples from the proficiency panel were assigned reference values by using exact-matching isotope-dilution mass spectrometry at LGC. RESULTS: The range of CVs observed with the tacrolimus proficiency panel was as follows: LC-MS 11.4%-18.7%, ARCHITECT 3.9%-9.5%, and Siemens Dade 5.0%-48.1%. The range of historical within-site QC CVs obtained with the use of 3 control concentrations were as follows: LC-MS low 3.8%-10.7%, medium 2.0%-9.3%, high 2.3%-9.0%; ARCHITECT low 2.5%-9.5%, medium 2.5%-8.6%, high 2.9%-18.6%; and Siemens/Dade Dimension low 8.7%-23.0%, medium 7.6%-13.2%, high 4.4%-10.4%. Assay bias observed between the 4 LC-MS sites was not corrected by implementation of a common calibrator set. CONCLUSIONS: Tacrolimus assay standardization will be necessary to compare patient results between clinical laboratories. Improved assay accuracy is required to provide optimized drug dosing and consistent care across transplant centers globally. (C) 2011 American Association for Clinical Chemistry
引用
收藏
页码:1739 / 1747
页数:9
相关论文
共 19 条
  • [1] Evaluation of 2 Immunoassays for Monitoring Low Blood Levels of Tacrolimus
    Amann, Shawn
    Parker, Thomas S.
    Levine, Daniel M.
    [J]. THERAPEUTIC DRUG MONITORING, 2009, 31 (02) : 273 - 276
  • [2] [Anonymous], 2010, AACC CAP IMMUNOSUPPR
  • [3] Production and certification of four frozen human serum certified reference materials containing creatinine and electrolytes
    Barbagallo, Romina P.
    Boley, Nick
    Holcombe, Gill
    Merson, Sheila
    Mussell, Chris
    Pritchard, Caroline
    Stokes, Peter
    Wood, Steve
    Ducroq, David
    Thomas, Annette
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 160 - 166
  • [4] Rheumatoid Factor Interference in a Tacrolimus Immunoassay
    Barcelo Martin, Bernardi
    Marquet, Pierre
    Maria Ferrer, Joana
    Castanyer Puig, Bartomeu
    Barcelo Bennasar, Antonia
    Riesco Prieto, Maria
    Fortuny Marques, Regina
    [J]. THERAPEUTIC DRUG MONITORING, 2009, 31 (06) : 743 - 745
  • [5] Calcineurin Inhibitor Minimization in the Symphony Study: Observational Results 3 Years after Transplantation
    Ekberg, H.
    Bernasconi, C.
    Tedesco-Silva, H.
    Vitko, S.
    Hugo, C.
    Demirbas, A.
    Reyes Acevedo, R.
    Grinyo, J.
    Frei, U.
    Vanrenterghem, Y.
    Daloze, P.
    Halloran, P. F.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2009, 9 (08) : 1876 - 1885
  • [6] Reduced exposure to calcineurin inhibitors in renal transplantation
    Ekberg, Henrik
    Tedesco-Silva, Helio
    Demirbas, Alper
    Vitko, Stefan
    Nashan, Bjorn
    Guerkan, Alp
    Margreiter, Raimund
    Hugo, Christian
    Grinyo, Josep M.
    Frei, Ulrich
    Vanrenterghem, Yves
    Daloze, Pierre
    Halloran, Philip F.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (25) : 2562 - 2575
  • [7] ELLISON SLR, 1995, QUANTIFYING UNCERTAI
  • [8] Immunosuppressive drugs for kidney transplantation
    Halloran, PF
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (26) : 2715 - 2729
  • [9] Falsely Increased Blood Tacrolimus Concentrations Using the ACMIA Assay Due to Circulating Endogenous Antibodies in a Liver Transplant Recipient: A Tentative Approach to Obtaining Reliable Results
    Hermida, Jesus
    Tutor, J. Carlos
    [J]. THERAPEUTIC DRUG MONITORING, 2009, 31 (02) : 269 - 272
  • [10] Therapeutic monitoring of Tacrolimus: Aberrant results by an immunoassay with automated pretreatment
    Moscato, Donatella
    Nonnato, Antonello
    Adamo, Rita
    Vancheri, Maria
    Caropreso, Antonio
    [J]. CLINICA CHIMICA ACTA, 2010, 411 (1-2) : 77 - 80