Assessment of electrochemical methods used on corrosion of superduplex stainless steel

被引:48
作者
de Assis, Kioshy S. [1 ]
de Sousa, Flavio V. V. [1 ]
Miranda, Marcelo [1 ]
Margarit-Mattos, Isabel C. P. [1 ]
Vivier, Vincent [2 ]
Mattos, Oscar R. [1 ]
机构
[1] COPPE Univ Fed Rio de Janeiro UFRJ, Lab Ensaios Nao Destrut Corrosao & Soldagem LNDC, BR-21945970 Rio De Janeiro, Brazil
[2] Univ Paris 06, LISE, UPR 15, CNRS, F-75252 Paris 05, France
关键词
Stainless steel; Cyclic voltammetry; SEM; Polarization; Intergranular corrosion; INTERGRANULAR CORROSION; LOCALIZED CORROSION; REACTIVATION TEST; MICROSCOPY; BEHAVIOR; SECM; SENSITIZATION; SPECTROSCOPY; RESISTANCE; IMPEDANCE;
D O I
10.1016/j.corsci.2012.02.014
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper addresses the electrochemical parameters proposed in ISO 12732 standard that are used to quantify undesirable phases in a superduplex stainless steel. The relationship among these electrochemical parameters (listed as the maximum current and overall charges ratio during the activation and reactivation polarization curves) and the quantity of undesirable phases were evaluated. It was shown that ferrite is always preferentially corroded in that steel. For aged conditions, the undesirable phases were satisfactorily detected by Double Loop Electrochemical Potentiokinetic Reactivation. A new experimental protocol developed made possible the characterization of the attack occurring at each polarization range. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 46 条
[1]   Dissolution characteristics of duplex stainless steels in acidic environments [J].
Aldykiewicz, AJ ;
Isaacs, HS .
CORROSION SCIENCE, 1998, 40 (10) :1627-1646
[2]   Double loop electrochemical potentiokinetic reactivation test optimization in checking of duplex stainless steel intergranular corrosion susceptibility [J].
Amadou, T ;
Braham, C ;
Sidhom, H .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2004, 35A (11) :3499-3513
[3]   Biological applications of scanning electrochemical microscopy: chemical imaging of single living cells and beyond [J].
Amemiya, Shigeru ;
Guo, Jidong ;
Xiong, Hui ;
Gross, Darrick A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (03) :458-471
[4]   Microstructural evolution and localized corrosion resistance of an aged superduplex stainless steel [J].
Angelini, E ;
De Benedetti, B ;
Rosalbino, F .
CORROSION SCIENCE, 2004, 46 (06) :1351-1367
[5]  
[Anonymous], 2006, ISO116071, P1
[6]  
[Anonymous], 2008, ASTM, Vi, P1, DOI [DOI 10.1520/MNL10913M, DOI 10.1520/E0837-13A.2]
[7]   Determination of susceptibility to intergranular corrosion and electrochemical reactivation behaviour of AISI 316L type stainless steel [J].
Aydogdu, G. H. ;
Aydinol, M. K. .
CORROSION SCIENCE, 2006, 48 (11) :3565-3583
[8]  
Bard AJ, 2001, MG ELEC CH, P1
[9]  
Barker AL, 2003, SURF SCI SERIES, V111, P253
[10]   Chemically-selective and spatially-localized redox activity at Ta/Ta2O5 electrodes [J].
Basame, SB ;
White, HS .
LANGMUIR, 1999, 15 (03) :819-825