Methylmercury in tuna:: demonstrating measurement capabilities and evaluating comparability of results worldwide from the CCQM P-39 comparison

被引:14
作者
Quétel, CR
Snell, JP
Aregbe, Y
Abrankó, L
Jókai, Z
Brunori, C
Morabito, R
Hagan, W
Azemard, S
Wyse, E
Fajon, V
Horvat, M
Logar, M
Donard, OFX
Krupp, E
Entwisle, J
Hearn, R
Schantz, M
Inagaki, K
Takatsu, A
Grinberg, P
Willlie, S
Dimock, B
Hintelmann, H
Zhu, J
Gonzalez, EB
Centineo, G
Alonso, JEG
Sanz-Medel, A
Björn, E
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, Isotop Measurement Unit,EC JRC IRMM, B-2440 Geel, Belgium
[2] Corvinus Univ Buddapest, Dept Appl Chem, BKAE ET, H-1118 Budapest, Hungary
[3] ENEA, PROT CHIM, CR Casaccia, I-00060 Rome, Italy
[4] Frontier GeoSci Inc, Seattle, WA 98109 USA
[5] IAEA, MEL, MC-98012 Monaco, Monaco
[6] Jozef Stefan Inst, Dept Environm Sci, Ljubljana 1111, Slovenia
[7] LCABIE, F-64000 Pau, France
[8] LGC Ltd, Teddington TW11 0LY, Middx, England
[9] NIST, Analyt Chem Div, Gaithersburg, MD 20899 USA
[10] Natl Inst Adv Sci & Technol AIST, Natl Metrol Inst Japan, Environm Stand Sect, Tsukuba, Ibaraki 3058563, Japan
[11] Natl Res Council Canada, INMS, Ottawa, ON K1A 0R6, Canada
[12] Trent Univ, Dept Chem, Peterborough, ON K9J 7B8, Canada
[13] Univ Oviedo, Dept Phys & Analyt Chem, Oviedo, Spain
[14] Umea Univ, Dept Chem, S-90187 Umea, Sweden
关键词
D O I
10.1039/b505368d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Six metrology institutes (NMIs) representing at the Comite 'International des Poids et Mesures (CIPM) 4 Member States of the Metre Convention and 2 international organisations, and 8 "expert'' laboratories selected outside CIPM have compared their capabilities to quantitatively measure methylmercury (MeHg) in a prepared tuna material containing approximately 4.3 mg kg(-1) Hg. This comparison was the object of the CIPM - Comite Consultatif pour la Quantite de Matiere (CCQM) Pilot Study 39, organised by the Institute for Reference Materials and Measurements (IRMM), from the European Commission - Joint Research Centre. Beside the test material itself, a bottle of the BCR-464 tuna Certified Reference Material (CRM) and an ampoule of IRMM-670, a 202 Hg isotope enriched MeHg candidate isotopic CRM, were distributed to all participants, who were free to apply the measurement strategy of their choice. Four, including 1 NMI, relied on external calibration or the method of standard additions, whereas the other 10 implemented an isotope dilution mass spectrometry (IDMS) approach and chose to use the IRMM-670 for their measurements. Alkaline digestion at room temperature ( with manual shaking) or high temperature ( under sonication, oven or hot plate conditions) was employed by most participants, with hydrochloric acid leaching the second most popular choice. Alkylation ( 4 phenylations, 4 ethylations and 3 propylations) in the aqueous phase was preferred by a large majority over butylation by the Grignard reaction. All participants were requested to estimate the uncertainty associated with their results and 9 out of 14 stated relative combined uncertainties below 6% (k = 2). Despite this apparent consensus, the perception of which factor caused the largest contribution to this estimation differed among participants because of the differences in the analytical methodologies deployed but also because of wide differences of the concepts of uncertainty estimation. The mixture mode' (MM) median, calculated also from the measurement uncertainties stated by the participants, was 1.967 +/- 0.204 x 10(-5) mol kg(-1) (95% confidence). Twelve of the results were re-grouped within a range of less than 0.3 x 10(-5) mol kg(-1) (MM median = 1.967 +/- 0.162 x 10(-5) mol kg(-1), 95% confidence): they nearly all (1 exception) overlapped with each other within k = 2 stated uncertainties. For the other 2 results the uncertainty seemed to have been particularly underestimated as they lay, respectively, at more than 20% above and less than - 40% below the overall average. The relative standard deviation of the results of 9 laboratories out of the 10 that applied IDMS was about 2.6%. It can be assumed from the degree of equivalence shown by 12 out of 14 study participants that, at present, laboratories worldwide are potentially able to supply accurate results for MeHg in fish-type matrices ( containing about 2 x 10(-5) mol kg(-1)) within +/- 10% uncertainty. This encouraging outcome permitted scheduling of a follow-up CCQM-K43 key comparison for a lower MeHg content level in salmon tissues.
引用
收藏
页码:1058 / 1066
页数:9
相关论文
共 45 条
[1]  
[Anonymous], BBC NEWS
[2]  
[Anonymous], 2004, EFSA Journal, V34, P1, DOI DOI 10.2903/J.EFSA.2004.34
[3]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[4]   CCQM-P39: As, Hg, Pb, Se and methylmercury in tuna fish [J].
Aregbe, Y. ;
Quetel, C. ;
Taylor, P. D. P. .
METROLOGIA, 2004, 41
[5]  
*BIPM PAV BRET SEV, 1995, RAPP 1 SESS
[6]   Mercury speciation analysis in sea water by solid phase microextraction-gas chromatography-inductively coupled plasma mass spectrometry using ethyl and propyl derivatization.: Matrix effects evaluation [J].
Bravo-Sánchez, LR ;
Encinar, JR ;
Martínez, JIF ;
Sanz-Medel, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (01) :59-66
[7]   Structured approach to achieving high accuracy measurements with isotope dilution inductively coupled plasma mass spectrometry [J].
Catterick, T ;
Fairman, B ;
Harrington, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :1009-1013
[8]  
*COMM TOX CHEM FOO, 2004, UPD COT STAT SURV ME
[9]   Sodium tetra(n-propyl)borate:: a novel aqueous in situ derivatization reagent for the simultaneous determination of organomercury, -lead and -tin compounds with capillary gas chromatography inductively coupled plasma mass spectrometry [J].
De Smaele, T ;
Moens, L ;
Dams, R ;
Sandra, P ;
Van der Eycken, J ;
Vandyck, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (01) :99-106
[10]  
DUEWER DL, 2004, CCQM0415 BIPM