Orthopedic hardware complications diagnosed with multi-detector row CT

被引:31
作者
Ohashi, K [1 ]
El-Khoury, GY [1 ]
Bennett, DL [1 ]
Restrepo, JM [1 ]
Berbaum, KS [1 ]
机构
[1] Univ Iowa, Roy J & Lucille A Carver Coll Med, Dept Radiol, Iowa City, IA 52242 USA
关键词
D O I
10.1148/radiol.2372041681
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To retrospectively evaluate multi-detector row computed tomography (CT) for the depiction of orthopedic hardware complications in the spine and appendicular skeleton. MATERIALS AND METHODS: This HIPAA-compliant study had institutional review board approval; patient informed consent was not required. Results of 114 multidetector row CT studies performed because of possible hardware complications in 109 patients (57 men, 52 women; mean age, 44 years; age range, 12-82 years) were available for analysis. The CT studies were retrospectively reviewed and compared with clinical or surgical outcomes, which were used as the reference standard. In another experiment, detection of hardware complications on radiographs and multi-detector row CT images was compared between two readers for selected cases (18 positive and 26 negative) by using receiver operating characteristic (ROC) methods. RESULTS: For 91 (80%) of 114 multi-detector row CT studies, the complication status could be determined on the basis of clinical or surgical outcomes. Twenty-three multi-detector row CT studies were confirmed to be positive (revealing 10 cases of nonunion, five cases of hardware malplacement, three cases of hardware loosening, three perihardware fractures, and two chronic infections), and 57 were confirmed to be negative. There were three false-positive and eight false-negative multi-detector row CT studies. With clinical or surgical outcomes as the reference standard, the sensitivity, specificity, and positive and negative predictive values of multi-detector row CT were 74% (23 of 31 studies), 95% (57 of 60 studies), 88% (23 of 26 studies), and 88% (57 of 65 studies), respectively. Results of ROC analysis indicated that detection of hardware,complications was much lower with radiography than with multi-detector row CT (area under ROC curve, 0.84 vs 1.00; F 4.69, df = 1, 43; P < .05). CONCLUSION: Multi-detector row CT is an effective tool for depicting orthopedic hardware complications. (c) RSNA, 2005.
引用
收藏
页码:570 / 577
页数:8
相关论文
共 31 条
[1]   Three-dimensional volume rendering of spiral CT data: Theory and method [J].
Calhoun, PS ;
Kuszyk, BS ;
Heath, DG ;
Carley, JC ;
Fishman, EK .
RADIOGRAPHICS, 1999, 19 (03) :745-764
[2]   MULTI-PLANAR RECONSTRUCTION AS A METHOD OF ELIMINATING STREAK ARTIFACT IN COMPUTED TOMOGRAPHIC-IMAGES [J].
CITRIN, CM .
COMPUTERIZED RADIOLOGY, 1982, 6 (06) :377-378
[3]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[4]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[5]  
DORMAN DD, RSCORE 4 66
[6]   Open reduction and internal fixation with bone grafting of clavicular nonunion [J].
Ebraheim, NA ;
Mekhail, AO ;
Darwich, M .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (04) :701-704
[7]   Imaging orthopedic hardware with an emphasis on hip prostheses [J].
Eustace, S ;
Shah, B ;
Mason, M .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (01) :67-+
[8]  
FARBER JM, 2003, SYLLABUS MUSCULOSKET, P119
[9]   METALLIC HIP IMPLANTS - CT WITH MULTIPLANAR RECONSTRUCTION [J].
FISHMAN, EK ;
MAGID, D ;
ROBERTSON, DD ;
BROOKER, AF ;
WEISS, P ;
SIEGELMAN, SS .
RADIOLOGY, 1986, 160 (03) :675-681
[10]   COMPUTED-TOMOGRAPHY OF THORACIC AND LUMBAR SPINE FRACTURES THAT HAVE BEEN TREATED WITH HARRINGTON INSTRUMENTATION [J].
GOLIMBU, C ;
FIROOZNIA, H ;
RAFII, M ;
ENGLER, G ;
DELMAN, A .
RADIOLOGY, 1984, 151 (03) :731-733