Heat transfer and flow characteristics of a pair of adjacent impinging synthetic jets

被引:43
作者
Fanning, Eoin [1 ]
Persoons, Tim [1 ]
Murray, Darina B. [1 ]
机构
[1] Trinity Coll Dublin, Dept Mech & Mfg Engn, Dublin 2, Ireland
关键词
Synthetic jet; Impinging jet; Vortex pair; Electronics cooling; Particle image velocimetry; Infrared thermography; MECHANISMS; SINGLE;
D O I
10.1016/j.ijheatfluidflow.2015.05.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
The local convective heat transfer rate of an impinging synthetic jet has been shown to rival that of an impinging steady jet. Recent research has demonstrated a significant degree of interaction between adjacent synthetic jets, especially when generated from rectangular orifices. When operated in an impingement setup, adjacent jet interaction has been shown to enhance the convective heat transfer performance in some cases. This paper presents the findings of an experimental study to determine the effect of the orifice-to-impingement surface distance, H, and orifice-to-orifice centre separation distance, S, of a pair of synthetic air jets formed by two rectangular orifices with a span-to-width aspect ratio of 27:1 and a slot width D = 1.65 mm. The local convective heat transfer coefficient is determined on an electrically heated thin metal foil using infrared thermography. Particle image velocimetry (PIV) measurements of the flow field between the jet orifices and the impingement surface were performed. The jets are maintained at a constant Reynolds number and stroke length (Re = 300, L-0/D = 29). For the parameter range considered (6 < H/D < 24, 3 < S/D < 12), an optimum configuration of H/D = 24 and S/D = 3 operated at a phase difference of 60 degrees < Phi < 120 degrees gives the highest average cooling performance. For hot spot cooling, a configuration of H/D = 6 and S/D = 3 operated at a phase difference of 135 degrees < Phi < 180 degrees gives the highest local maximum heat transfer. These results demonstrate the potential of this double impinging synthetic jet arrangement for actively controlled heat transfer applications. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:153 / 166
页数:14
相关论文
共 26 条
[1]   Controlled transients of flow reattachment over stalled airfoils [J].
Amitay, M ;
Glezer, A .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2002, 23 (05) :690-699
[2]   Optimization of synthetic jet cooling for microelectronics applications [J].
Beratlis, N ;
Smith, MK .
NINETEENTH ANNUAL IEEE SEMICONDUCTOR THERMAL MEASUREMENT AND MANAGEMENT SYMPOSIUM, 2003, :66-73
[3]   Thermal management of a laptop computer with synthetic air microjets [J].
Campbell, JS ;
Black, WZ ;
Glezer, A ;
Hartley, JG .
ITHERM '98: SIXTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, 1998, :43-50
[4]   Heat transfer characteristics of a micro-scale impinging slot jet [J].
Choo, Kyo Sung ;
Youn, Young Jik ;
Kim, Sung Jin ;
Lee, Dae Hee .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (13-14) :3169-3175
[5]  
Fanning E., 2013, 8 WORLD C EXP HEAT T
[6]   Local convective heat transfer from a constant heat flux flat plate cooled by synthetic air jets [J].
Gillespie, M. B. ;
Black, W. Z. ;
Rinehart, C. ;
Glezer, A. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2006, 128 (10) :990-1000
[7]   Synthetic jets [J].
Glezer, A ;
Amitay, M .
ANNUAL REVIEW OF FLUID MECHANICS, 2002, 34 :503-529
[8]   Time and phase average heat transfer in single and twin circular synthetic impinging air jets [J].
Greco, Carlo Salvatore ;
Ianiro, Andrea ;
Cardone, Gennaro .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 73 :776-788
[9]   On the near field of single and twin circular synthetic air jets [J].
Greco, Carlo Salvatore ;
Ianiro, Andrea ;
Astarita, Tommaso ;
Cardone, Gennaro .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2013, 44 :41-52
[10]   Formation criterion for synthetic jets [J].
Holman, R ;
Utturkar, Y ;
Mittal, R ;
Smith, BL ;
Cattafesta, L .
AIAA JOURNAL, 2005, 43 (10) :2110-2116