Investigation of the performance of lateral ventilation in subway station fires

被引:17
作者
Chen, Junfeng [1 ]
Long, Zeng [1 ]
Liu, Chang [1 ]
Cai, Shuang [2 ]
Xu, Bingzhou [3 ,4 ]
Cheng, Huihang [1 ]
Zhong, Maohua [1 ,5 ]
机构
[1] Tsinghua Univ, Inst Publ Safety Res, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Beijing Metro Operat Adm Corp Ltd, Beijing 100000, Peoples R China
[3] China Railway First Grp Construct & Installat Eng, Xian 710054, Peoples R China
[4] China Railway First Grp Co Ltd, Xian 710054, Peoples R China
[5] Tsinghua Univ, Inst Publ Safety Res, Dept Engn Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Subway station; Fire; Lateral ventilation; Smoke control; SMOKE LAYER THICKNESS; TRAIN FIRE; EMERGENCY VENTILATION; NATURAL VENTILATION; FLOW LENGTH; LIFE SAFETY; TUNNEL; MODE; TEMPERATURE; SIMULATION;
D O I
10.1016/j.jweia.2022.105133
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Lateral ventilation has been widely used in tunnel ventilation in recent years. But the effect of lateral ventilation in subway stations has received little attention and discussion. Based on numerical simulation, a real standard subway station is modelled in this paper to study the applicability of lateral ventilation in subway stations. Both the traditional ventilation system with vents located at the bottom of ventilation ducts and the proposed lateral ventilation system with vents located at the side of ventilation ducts are presented and compared. Parameters including temperature, CO concentration, and smoke layer height are adopted to qualitatively study the smoke control effect of different vent layouts. Parameters including ventilation efficiency and fractional effective dose are adopted to quantitatively model the ventilation performance of different vent layouts. The results indicate that: (1) The side vent layout is recommended in subway station emergency ventilation with slower horizontal smoke diffusion, slower vertical smoke settlement, and better smoke layer stability. (2) The advantage of side vent layout is quantitatively validated with higher ventilation efficiency in every vent and lower gas toxicity at eye-sight height. (3) Sensitivity analysis of fire location, heat release rate, vent amount, and vent size are con-ducted to verify the advantage of the side vent layout. In all scenario groups simulated, a better smoke control performance, higher ventilation efficiency, and lower fractional effective dose value is acquired in side vent layout. This research presents the application prospect and design method of lateral ventilation in subway stations.
引用
收藏
页数:16
相关论文
共 64 条
[1]  
[Anonymous], 2018, NIST Special Publication
[2]   Full-scale experimental and numerical studies on compartment fire under low ambient temperature [J].
Bystrom, Alexandra ;
Cheng, Xudong ;
Wickstrom, Ulf ;
Veljkovic, Milan .
BUILDING AND ENVIRONMENT, 2012, 51 :255-262
[3]   Ventilation inlets design based on ventilation performance assessment using a dimensionless time scale [J].
Cao, Shi-Jie ;
Deng, Hua-Yan ;
Zhou, Xiaoqing ;
Deng, Yelin .
INDOOR AND BUILT ENVIRONMENT, 2019, 28 (08) :1049-1063
[4]   Experimental investigation and numerical simulation of a furnished office fire [J].
Chen, Chien-Jung ;
Hsieh, Wei-Dong ;
Hu, Wei-Chieh ;
Lai, Chi-ming ;
Lin, Ta-Hui .
BUILDING AND ENVIRONMENT, 2010, 45 (12) :2735-2742
[5]   Thermal buoyant smoke back-layering flow length in a longitudinal ventilated tunnel with ceiling extraction at difference distance from heat source [J].
Chen, L. F. ;
Hu, L. H. ;
Zhang, X. L. ;
Zhang, X. Z. ;
Zhang, X. C. ;
Yang, L. Z. .
APPLIED THERMAL ENGINEERING, 2015, 78 :129-135
[6]   The effect of vent inlet aspect ratio and its location on ventilation efficiency [J].
Chen, Tingsen ;
Feng, Zhuangbo ;
Cao, Shi-Jie .
INDOOR AND BUILT ENVIRONMENT, 2020, 29 (02) :180-195
[7]  
China S.A.O., 2017, GB/T 33668-2017
[8]   Experimental studies on the smoke extraction performance by different types of ventilation shafts in extra-long road tunnel fires [J].
Cong, Haiyong ;
Bi, Mingshu ;
Bi, Yubo ;
Li, Yanchao ;
Jiang, Haipeng ;
Gao, Wei .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 115
[9]   Experimental study of air entrainment mode with natural ventilation using shafts in road tunnel fires [J].
Fan, C. G. ;
Ji, J. ;
Gao, Z. H. ;
Han, J. Y. ;
Sun, J. H. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 56 (1-2) :750-757
[10]   Numerical analysis of smoke dispersion against the wind in a tunnel fire [J].
Gannouni, Soufien ;
Ben Maad, Rejeb .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2016, 158 :61-68