Distinguishing hepatic metastases from hemangiomas - Qualitative and quantitative diagnostic performance through dual echo respiratory-triggered fast spin echo magnetic resonance imaging

被引:12
作者
Kim, YH
Saini, S
Blake, MA
Harisinghani, M
Chiou, YY
Lee, WJ
Yu, JS
Hahn, PF
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[2] Univ Massachusetts, Sch Med, Dept Radiol, Umass Mem Hlth Care, Worcester, MA USA
[3] Emory Univ, Sch Med, Dept Radiol, Emory Univ Hosp, Atlanta, GA 30322 USA
[4] Taipei Vet Gen Hosp, Dept Radiol, Taipei, Taiwan
[5] Korea Univ, Coll Med, Dept Prevent Med, Seoul 136701, South Korea
[6] Yonsei Univ, Dept Diagnost Radiol, YongDong Severance Hosp, Coll Med, Seoul 120749, South Korea
关键词
liver; magnetic resonance; liver neoplasms; technology;
D O I
10.1097/01.rct.0000172671.71446.33
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine the relative value of qualitative (reader opinion) and quantitative (values derived from dual echo T2 fast spin echo [FSE]) measures in distinguishing hepatic metastases from hemangiomas. Methods: Forty-nine patients with hemangiomas and 23 with metastases were studied with dual echo respiratory-triggered FSE and dynamic 2-dimensional spoiled gradient echo (GRE) imaging. Lesion T2 was estimated from signal intensity ratios on the first and second echoes. Two experienced radiologists independently evaluated groups of images based on 5 separate qualitative measures: first echo FSE, second echo FSE, first and second echo FSE, dynamic GRE, and all images together. Results: The mean calculated T2s were 226 +/- 74 milliseconds for hemangiomas and 105 +/- 22 milliseconds for metastases (P < 0.001). A T2 cutoff of 130 milliseconds distinguished metastases from hemangiomas with a sensitivity of 94%, specificity of 91%, and accuracy of nearly 94%. There was no significant difference between the best quantitative measure and the best qualitative measure for either reader. Conclusion: Liver lesion T2 relaxation times calculated from dual echo FSE images provide information useful in discriminating metastases from hemangiomas, as does reader opinion.
引用
收藏
页码:571 / 579
页数:9
相关论文
共 25 条
  • [1] Single-shot T2-weighted MR imaging of the upper abdomen: Preliminary experience with double-echo HASTE technique
    Bosmans, H
    VanHoe, L
    Gryspeerdt, S
    Kiefer, B
    VanSteenbergen, W
    Baert, AL
    Marchal, G
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1291 - 1293
  • [2] Cittadini Giuseppe, 2004, Radiol Med, V107, P166
  • [3] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [4] Signal characteristics of focal liver lesions on double echo T2-weighted conventional spin echo MRI: Observer performance versus quantitative measurements of T2 relaxation times
    Fenlon, HM
    Tello, R
    deCarvalho, VLS
    Yucel, EK
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 204 - 211
  • [5] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    [J]. RADIOLOGY, 1996, 200 (02) : 459 - 464
  • [6] VALUE OF T1-RELAXATION AND T2-RELAXATION TIMES FROM ECHOPLANAR MR IMAGING IN THE CHARACTERIZATION OF FOCAL HEPATIC-LESIONS
    GOLDBERG, MA
    HAHN, PF
    SAINI, S
    COHEN, MS
    REIMER, P
    BRADY, TJ
    MUELLER, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1011 - 1017
  • [7] DIFFERENTIATION BETWEEN HEMANGIOMAS AND METASTASES OF THE LIVER WITH ULTRAFAST MR IMAGING - PRELIMINARY-RESULTS WITH T2 CALCULATIONS
    GOLDBERG, MA
    SAINI, S
    HAHN, PF
    EGGLIN, TK
    MUELLER, PR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) : 727 - 730
  • [8] FOCAL LIVER-LESIONS - CHARACTERIZATION WITH NONENHANCED AND DYNAMIC CONTRAST MATERIAL-ENHANCED MR-IMAGING
    HAMM, B
    THOENI, RF
    GOULD, RG
    BERNARDINO, ME
    LUNING, M
    SAINI, S
    MAHFOUZ, AE
    TAUPITZ, M
    WOLF, KJ
    [J]. RADIOLOGY, 1994, 190 (02) : 417 - 423
  • [9] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843
  • [10] Hepatic lesions: Discrimination of nonsolid, benign lesions from solid, malignant lesions with heavily T2-weighted fast spin-echo MR imaging
    Ito, K
    Mitchell, DG
    Outwater, EK
    Szklaruk, J
    Sadek, AG
    [J]. RADIOLOGY, 1997, 204 (03) : 729 - 737