Dentin thickness; micro-computed tomographic imaging; root canal preparation; root canal transportation; unprepared canal surface area; MICRO-COMPUTED-TOMOGRAPHY; VERTICAL ROOT FRACTURE; SELF-ADJUSTING FILE; CURVED CANALS; TREATED TEETH; MECHANICAL-PROPERTIES; APICAL PERIODONTITIS; INSTRUMENT SYSTEMS; ROTARY INSTRUMENTS; CYCLIC FATIGUE;
D O I
10.1016/j.joen.2017.04.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study compared the shaping ability of ProTaper Next (Dentsply Sirona, Tulsa, OK) and BT-RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) instrument systems in the mesial canals of mandibular molars using micro-computed tomographic (micro-CT) imaging. Methods: A total of 17 type IV mesial roots of extracted first mandibular molars were scanned using micro-CT imaging before and after root canal preparation with the 2 instrument systems. Both systems were used in the same root but alternating the mesial canals from root to root. The following parameters were analyzed: root canal volume, surface area, unprepared surface areas, transportation, canal/root width ratio, and preparation time. Results: There were no statistically significant differences between the 2 systems for all evaluated parameters (P > .05). The unprepared surface areas for the full canal length and the apical 5-mm segment were 33% and 14% for BT-RaCe and 31% and 14% for ProTaper Next, respectively. After preparation, all root canals had a diameter that was not larger than 35% of the root diameter at the coronal and middle segments. Conclusions: The 2 systems showed no differences in any of the evaluated shaping parameters. None of the tested systems put the roots at risk of fracture because of excessive dentin removal.
引用
收藏
页码:1683 / 1687
页数:5
相关论文
共 32 条
[1]   The effect of endodontic procedures on apical crack initiation and propagation ex vivo [J].
Adorno, C. G. ;
Yoshioka, T. ;
Jindan, P. ;
Kobayashi, C. ;
Suda, H. .
INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (08) :763-768
[2]   Removal of Root Canal Fillings in Curved Canals Using Either Reciprocating Single- or Rotary Multi-instrument Systems and a Supplementary Step with the XP-Endo Finisher [J].
Alves, Flavio R. F. ;
Marceliano-Alves, Marilia F. ;
Sousa, Julio Cezar N. ;
Silveira, Stephanie B. ;
Provenzano, Jose C. ;
Siqueira, Jose F., Jr. .
JOURNAL OF ENDODONTICS, 2016, 42 (07) :1114-1119
[3]   Shaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals [J].
Buerklein, S. ;
Mathey, D. ;
Schaefer, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (08) :774-781
[4]   Micro-Computed Tomographic Evaluation of 2 Nickel-Titanium Instrument Systems in Shaping Root Canals [J].
da Silva Limoeiro, Ana Grasiela ;
Braitt dos Santos, Antonio Henrique ;
De Martin, Alexandre Sigrist ;
Kato, Augusto Shoji ;
Fontana, Carlos Eduardo ;
Gavini, Giulio ;
Freire, Laila Gonzales ;
da Silveira Bueno, Carlos Eduardo .
JOURNAL OF ENDODONTICS, 2016, 42 (03) :496-499
[5]  
Debelian G, 2014, ROOTS, V10, P20
[6]   Laboratory comparison of the mechanical properties of TRUShape with several nickel-titanium rotary instruments [J].
Elnaghy, A. M. ;
Elsaka, S. E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (08) :805-812
[7]   Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals [J].
Kim, H. C. ;
Kim, H. J. ;
Lee, C. J. ;
Kim, B. M. ;
Park, J. K. ;
Versluis, A. .
INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (07) :593-602
[8]   Patterns of vertical root fracture: Factors affecting stress distribution in the root canal [J].
Lertchirakarn, V ;
Palamara, JEA ;
Messer, HH .
JOURNAL OF ENDODONTICS, 2003, 29 (08) :523-528
[9]   Do procedural errors cause endodontic treatment failure? [J].
Lim, LM ;
Rosenberg, PA ;
Lin, JS .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2005, 136 (02) :187-193
[10]   Effects of Electropolishing Surface Treatment on the Cyclic Fatigue Resistance of BioRace Nickel-Titanium Rotary Instruments [J].
Lopes, Helio P. ;
Elias, Carlos N. ;
Vieira, Victor T. L. ;
Moreira, Edson J. L. ;
Marques, Raquel V. L. ;
Machado de Oliveira, Julio C. ;
Debelian, Gilberto ;
Siqueira, Jose F., Jr. .
JOURNAL OF ENDODONTICS, 2010, 36 (10) :1653-1657