Coronary artery anomalies with a shunt: Evaluation with electron-beam CT

被引:16
|
作者
Yoshimura, N [1 ]
Hamada, S [1 ]
Takamiya, M [1 ]
Kuribayashi, S [1 ]
Kimura, K [1 ]
机构
[1] Natl Cardiovasc Ctr, Dept Radiol, Osaka, Japan
关键词
arteries; anomalies; coronary; shunts and shunting; computed tomography;
D O I
10.1097/00004728-199809000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal was to evaluate the role of electron-beam CT (EBT) in the diagnosis of patients with coronary artery anomalies with a shunt. Method: We performed EBT in seven patients with coronary artery anomalies with a shunt. Four cases were coronary artery fistula (CAF) and three were an anomalous origin of the left coronary artery from the pulmonary artery (ALCA from PA). Serial single volume mode scanning was performed at end-diastole to evaluate the anatomical course of the anomalous coronary arteries. Cine mode scanning was done in all but one to examine the ventricular wall motion and volumetrics. Results: EBT could detect the course and drainage sites of all CAFs and ALCAs from PA. Cine mode scanning revealed reduced wall motion in one case with CAF and two cases with ALCA from PA. Conclusion: EBT serves a useful role in the assessment of coronary artery anomalies with a shunt.
引用
收藏
页码:682 / 686
页数:5
相关论文
共 50 条
  • [1] Evaluation of corollary artery stenoses using electron-beam CT and multiplanar reformation
    Nakanishi, T
    Ito, K
    Imazu, M
    Yamakido, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) : 121 - 127
  • [2] Electron-beam CT angiography with three-dimensional reconstruction in the evaluation of coronary artery bypass grafts
    Dai, RP
    Zhang, SX
    Lu, B
    Cao, C
    He, S
    Bai, H
    Jing, BL
    ACADEMIC RADIOLOGY, 1998, 5 (12) : 863 - 867
  • [3] Causes of interscan variability of coronary artery calcium measurements at electron-beam CT
    Lu, B
    Budoff, MJ
    Zhuang, N
    Child, J
    Bakhsheshi, H
    Carson, S
    Mao, SS
    ACADEMIC RADIOLOGY, 2002, 9 (06) : 654 - 661
  • [4] SAPHENOUS-VEIN CORONARY-ARTERY BYPASS GRAFT ANEURYSM DEMONSTRATED BY ELECTRON-BEAM CT
    JOHNSON, PR
    TRUITT, TD
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (03) : 488 - 491
  • [5] Electron-beam CT: The effect of using a correction function on coronary artery calcium quantitation
    Greaser, LE
    Yoon, HC
    Mather, RT
    McNitt-Gray, M
    Goldin, JG
    ACADEMIC RADIOLOGY, 1999, 6 (01) : 40 - 48
  • [6] AN ELECTRON-BEAM CT APPROACH FOR TRANSVENOUS CORONARY ARTERIOGRAPHY
    THOMAS, PJ
    MCCOLLOUGH, CH
    RITMAN, EL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) : 383 - 389
  • [7] Dual energy for material differentiation in coronary arteries using electron-beam CT
    Sengupta, S
    Jha, S
    Walter, D
    Du, YF
    Tkaczyk, EJ
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1306 - 1316
  • [8] Coronary artery motion in electron beam tomography
    Mao, SS
    Lu, B
    Oudiz, RJ
    Bakhsheshi, H
    Liu, SCK
    Budoff, MJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 253 - 258
  • [9] Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography
    L. H. Piers
    J. Dorgelo
    R. A. Tio
    G. A. J. Jessurun
    M. Oudkerk
    F. Zijlstra
    The International Journal of Cardiovascular Imaging, 2005, 21 : 447 - 451
  • [10] Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography
    Piers, LH
    Dorgelo, J
    Tio, RA
    Jessurun, GAJ
    Oudkerk, M
    Zijlstra, F
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (04) : 447 - 451