Parametric study of multi-story, perforated, partially grouted masonry walls subjected to in-plane cyclic actions

被引:14
作者
Medeiros, Klaus A. S. [1 ]
Chavez, Kyle H. [2 ]
Fonseca, Fernando S. [2 ]
Parsekian, Guilherme A. [3 ]
Shrive, Nigel G. [4 ]
机构
[1] Fed Rural Univ Semiarid, Engn Dept, 587 Gamaliel Martins Bezerra St, BR-59515000 Angicos, RN, Brazil
[2] Brigham Young Univ, Civil & Environm Engn, 430 EB, Provo, UT 84602 USA
[3] Univ Fed Sao Carlos, Civil Engn Grad Program, Washington Luiz Highway,Km 235, BR-13565905 Sao Paulo, Brazil
[4] Univ Calgary, Schulich Sch Engn, Dept Civil Engn, 2500 Univ Dr NW, Calgary, AB, Canada
基金
巴西圣保罗研究基金会;
关键词
multi-story; partially grouted; opening; masonry; shear wall; finite element analysis; SHEAR-STRENGTH;
D O I
10.1139/cjce-2020-0128
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Finite element models were developed to assess the influence of several parameters on the load capacity, deflection, and initial stiffness of multi-story, partially grouted masonry walls with openings. The base model was validated with experimental data from three walls. The analyses indicated that the load capacity of masonry walls was considerably sensitive to the ungrouted and grouted masonry strengths and mortar shear strength; moderately sensitive to the vertical reinforcement ratio and aspect ratio; slightly sensitive to the axial stress; and almost insensitive to the opening size, reinforcement spacing, and horizontal reinforcement ratio. The deflection of the walls had well-defined correlations with the masonry strength, vertical reinforcement, axial stress, and aspect ratio. The initial stiffness was especially sensitive to the axial stress and the aspect ratio, but weakly correlated with the opening size, and the spacing and size of the reinforcement.
引用
收藏
页码:1046 / 1055
页数:10
相关论文
共 32 条
[1]  
[Anonymous], 2011, VECTOR2
[2]   Influence of a window-type opening on the shear response of partially-grouted masonry shear walls [J].
Calderon, Sebastian ;
Sandoval, Cristian ;
Inzunza, Ernesto ;
Cruz-Noguez, Carlos ;
Rahim, Amr Ba ;
Vargas, Laura .
ENGINEERING STRUCTURES, 2019, 201
[3]   Shear response of partially-grouted reinforced masonry walls with a central opening: Testing and detailed micro-modelling [J].
Calderon, Sebastian ;
Sandoval, Cristian ;
Arnau, Oriol .
MATERIALS & DESIGN, 2017, 118 :122-137
[4]  
Drysdale R.G., 1999, MASONRY STRUCTURES B
[5]  
Elmapruk J.H., 2010, Shear Strength of Partially Grouted Squat Masonry Shear Walls
[6]  
Fodi A, 2010, POLLACK PERIODICA, V5, P71, DOI [10.1556/Pollack.5.2010.3.7, DOI 10.1556/POLLACK.5.2010.3.7]
[7]  
Fortes E.S, 2017, THESIS U FEDERAL SAO THESIS U FEDERAL SAO
[8]   Parametrical study of masonry walls subjected to in-plane loading through numerical modeling [J].
Haach, Vladimir G. ;
Vasconcelos, Graca ;
Lourenco, Paulo B. .
ENGINEERING STRUCTURES, 2011, 33 (04) :1377-1389
[9]  
Hognestad E., 1951, B SERIES, V49
[10]  
Klingner R. E., 1992, P 10 WORLD C EARTHQ P 10 WORLD C EARTHQ