Bioanalytical liquid chromatography tandem mass spectrometry methods on underivatized silica columns with aqueous/organic mobile phases

被引:233
作者
Weng, ND [1 ]
机构
[1] Covance Labs Inc, Madison, WI 53704 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 796卷 / 02期
关键词
reviews; silica columns; aqueous/organic mobile phases;
D O I
10.1016/j.jchromb.2003.08.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review article summarizes the recent progress on bioanalytical LC-MS/MS methods using underivatized silica columns and aqueous/organic mobile phases. Various types of polar analytes were extracted by using protein precipitation (PP), liquid/liquid extraction (LLE) or solid-phase extraction (SPE) and were then analyzed using LC-MS/MS on the silica columns. Use of silica columns and aqueous/organic mobile phases could significantly enhance LC-MS/MS method sensitivity, due to the high organic content in the mobile phase. Thanks to the very low backpressure generated from the silica column with low aqueous/high organic mobile phases, LC-MS/MS methods at high flow rates are feasible, resulting in significant timesaving. Because organic solvents have weaker eluting strength than water, direct injection of the organic solvent extracts from the reversed-phase solid-phase extraction onto the silica column was possible. Gradient elution on the silica columns using aqueous/organic mobile phases was also demonstrated. Contrary to what is commonly perceived, the silica column demonstrated superior column stability. This technology can be a valuable supplement to the reversed-phase LC-MS/MS. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 224
页数:16
相关论文
共 76 条
[11]   STUDY OF THE RETENTION MECHANISMS FOR BASIC COMPOUNDS ON SILICA UNDER PSEUDO-REVERSED-PHASE CONDITIONS [J].
COX, GB ;
STOUT, RW .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :315-336
[12]   REVERSED-PHASE ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DRUGS AND RELATED-COMPOUNDS USING UNDERIVATIZED SILICA AS THE STATIONARY PHASE [J].
CROMMEN, J .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :705-724
[13]   Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma [J].
Eerkes, A ;
Shou, WZ ;
Weng, ND .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) :917-928
[14]   Simultaneous assay of sildenafil and desmethylsildenafil in human plasma using liquid chromatography-tandem mass spectrometry on silica column with aqueous-organic mobile phase [J].
Eerkes, A ;
Addison, T ;
Weng, ND .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 768 (02) :277-284
[15]   A sensitive and high-throughput LC/MS/MS method using a silica column and an aqueous-organic mobile phase for the analysis of fluoxetine and norfluoxetine in human plasma [J].
Eerkes, A ;
Weng, ND ;
King, M ;
Du, A ;
Zhou, WZ .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2002, 25 (08) :1215-1227
[16]  
GAO Y, 2003, J PHARM BIOMED ANAL, V31, P1191
[17]   Determination of folates in human plasma using hydrophilic interaction chromatography-tandem mass spectrometry [J].
Garbis, SD ;
Melse-Boonstra, A ;
West, CE ;
van Breemen, RB .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5358-5364
[18]  
GILL R, 1987, J CHROMATOGR, V386, P65
[19]  
GRAY A, 2000, PRINCIPLES PRACTICE, P62
[20]   ANALYSIS OF QUATERNARY AMMONIUM-COMPOUNDS AND BASIC DRUGS BASED ON ION-PAIR ADSORPTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GREVING, JE ;
BOUMAN, H ;
JONKMAN, JHG ;
WESTENBERG, HGM ;
DEZEEUW, RA .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :683-690