Characterization of Thermoluminescent Dosimeters for Neutron Dosimetry at High Altitudes

被引:6
|
作者
D'Avino, Vittoria [1 ,2 ]
Ambrosino, Fabrizio [1 ,2 ]
Bedogni, Roberto [3 ]
Campoy, Abner Ivan C. [3 ]
La Verde, Giuseppe [1 ,2 ]
Vernetto, Silvia [4 ,5 ]
Vigorito, Carlo Francesco [5 ,6 ]
Pugliese, Mariagabriella [1 ,2 ]
机构
[1] Natl Inst Nucl Phys INFN, Sect Naples, Via Cinthia, I-80126 Naples, Italy
[2] Univ Naples Federico II, Dept Phys Ettore Pancini, Via Cinthia, I-80126 Naples, Italy
[3] Natl Inst Nucl Phys INFN, Frascati Natl Labs, Via Enrico Fermi 54, I-00044 Frascati, Italy
[4] Natl Inst Astrophys, Astrophys Observ Turin INAF OATO, Via Pietro Giuria 1, I-10125 Turin, Italy
[5] Natl Inst Nucl Phys INFN, Sect Turin, Via Pietro Giuria 1, I-10125 Turin, Italy
[6] Univ Turin, Dept Phys, Via P Giuria 1, I-10125 Turin, Italy
关键词
charged particle; neutron detectors; cosmic radiation monitoring; neutron dosimetry; South Atlantic anomaly; thermoluminescent dosimeters calibration; thermal neutron facility; TLD pair; MAGNETIC-FIELD; COSMIC-RAYS; RADIATION; SPECTROMETRY; FACILITY; MONITOR; HOTNES; PAIRS;
D O I
10.3390/s22155721
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Neutrons constitute a significant component of the secondary cosmic rays and are one of the most important contributors to natural cosmic ray radiation background dose. The study of the cosmic ray neutrons' contribution to the dose equivalent received by humans is an interesting and challenging task for the scientific community. In addition, international regulations demand assessing the biological risk due to radiation exposure for both workers and the general population. Because the dose rate due to cosmic radiation increases significantly with altitude, the objective of this work was to characterize the thermoluminescent dosimeter (TLDs) from the perspective of exposing them at high altitudes for longtime neutron dose monitoring. The pair of TLD-700 and TLD-600 is amply used to obtain the information on gamma and neutron dose in mixed neutron-gamma fields due to the present difference in 6Li isotope concentration. A thermoluminescence dosimeter system based on pair of TLD-600/700 was characterized to enable it for neutron dosimetry in the thermal energy range. The system was calibrated in terms of neutron ambient dose equivalent in an experimental setup using a 241Am-B radionuclide neutron source coated by a moderator material, polyethylene, creating a thermalized neutron field. Afterward, the pair of TLD-600/700 was exposed at the CERN-EU High-Energy Reference Field (CERF) facility in Geneva, which delivers a neutron field with a spectrum similar to that of secondary cosmic rays. The dosimetric system provided a dose value comparable with the calculated one demonstrating a good performance for neutron dosimetry.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A REVIEW ON THE ROLE OF THERMOLUMINESCENT DOSIMETERS IN FAST-NEUTRON PERSONNEL DOSIMETRY
    LAKSHMANAN, AR
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1982, 6 (2-3): : 59 - 78
  • [2] Application of thermoluminescent dosimeters to mixed neutron-gamma dosimetry for BNCT
    Kessler, C
    Stecher-Rasmussen, F
    Rassow, J
    Garbe, S
    Sauerwein, W
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1165 - 1173
  • [3] RADIOIMMUNOTHERAPY DOSIMETRY USING THERMOLUMINESCENT DOSIMETERS
    SULLIVAN, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (06): : 734 - 735
  • [4] PERSONNEL DOSIMETRY USING THERMOLUMINESCENT DOSIMETERS
    CUSIMANO, JP
    CIPPERLEY, FV
    HEALTH PHYSICS, 1968, 14 (04): : 339 - +
  • [5] NEUTRON MONITORING WITH THERMOLUMINESCENT DOSIMETERS
    RANK, EX
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1025 - 1025
  • [6] A COMPARISON OF SEMICONDUCTOR AND THERMOLUMINESCENT DOSIMETERS FOR INVIVO DOSIMETRY
    AUKETT, RJ
    BRITISH JOURNAL OF RADIOLOGY, 1991, 64 (766): : 947 - 952
  • [7] NEUTRON MEASUREMENT USING THERMOLUMINESCENT DOSIMETERS
    ENGELKE, MJ
    HEALTH PHYSICS, 1970, 19 (02): : 331 - +
  • [8] NEW SINTERED THERMOLUMINESCENT DOSIMETERS FOR PERSONNEL AND ENVIRONMENTAL DOSIMETRY
    PROKIC, MS
    HEALTH PHYSICS, 1982, 42 (06): : 849 - 855
  • [9] Stereotactic radiosurgery dosimetry using thermoluminescent dosimeters and radiochromic films
    Avila-Rodríguez, MA
    Rodríguez-Villafuerte, M
    Perches, RD
    MEDICAL PHYSICS, 2000, 538 : 213 - 218
  • [10] In vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy
    Costa, Alessandro M.
    Barbi, Gustavo L.
    Bertucci, Edenyse C.
    Ferreira, Heberton
    Sansavino, Simone Z.
    Colenci, Beatriz
    Caldas, Linda V. E.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (4-5) : 760 - 762