Diagnostic Value of Cardiac CT in the Evaluation of Bicuspid Aortic Stenosis: Comparison With Echocardiography and Operative Findings

被引:71
|
作者
Tanaka, Ryoichi [1 ]
Yoshioka, Kunihiro [1 ]
Niinuma, Hiroyuki [2 ]
Ohsawa, Satoshi [3 ]
Okabayashi, Hitoshi [3 ]
Ehara, Shigeru [4 ]
机构
[1] Iwate Med Univ, Mem Heart Ctr, Dept Cardiovasc Radiol, Morioka, Iwate 0208505, Japan
[2] Iwate Med Univ, Mem Heart Ctr, Dept Cardiol, Morioka, Iwate 0208505, Japan
[3] Iwate Med Univ, Mem Heart Ctr, Dept Cardiovasc Surg, Morioka, Iwate 0208505, Japan
[4] Iwate Med Univ, Dept Radiol, Morioka, Iwate 0208505, Japan
关键词
aortic stenosis; bicuspid aortic valve; CT; echocardiography; SPIRAL COMPUTED-TOMOGRAPHY; VALVE AREA; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ASCENDING AORTA; ATHEROSCLEROTIC DISEASE; PLANIMETRY; STROKE; MDCT; QUANTIFICATION; CALCIFICATION;
D O I
10.2214/AJR.09.3164
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was conducted to assess the diagnostic value of cardiac CT for the evaluation of patients with bicuspid aortic valve disease. MATERIALS AND METHODS. Fifty consecutive patients with aortic stenosis who underwent surgical valve repair between September 2005 and November 2006 were examined by ECG-gated CT and echocardiography. A 64-MDCT scanner was used. The image findings regarding the number of leaflets (bicuspid or tricuspid) were compared against the intraoperative findings and were statistically analyzed by one-way univariate analysis of variance. The aortic valve area (AVA) was also measured by CT and echocardiography, and the measured values were statistically compared by use of the paired Student's t test. RESULTS. Seventeen patients had a bicuspid aortic valve, and 33 had a tricuspid aortic valve. In 10 of the 50 patients, echocardiography was unable to depict the type of aortic valve because of extensive calcification. The sensitivity, specificity, positive predictive value, and negative predictive value for the detection of a bicuspid aortic valve were 76.5%, 60.6%, 68.4%, and 95.2%, respectively, for echocardiography and 94.1%, 100%, 100%, and 97.1%, respectively, for CT. The CT findings were not significantly different from the intraoperative findings (p = 0.99), but the echocardiographic findings were (p < 0.05). The AVA measurements obtained by CT and echocardiography were 0.940 +/- 0.44 cm(2) and 0.659 +/- 0.234 cm(2), respectively, showing a significant difference (p < 0.05). CONCLUSION. ECG-gated cardiac CT is useful for the accurate morphologic assessment of bicuspid aortic stenosis, especially in patients with severe valve calcification.
引用
收藏
页码:895 / 899
页数:5
相关论文
共 50 条
  • [1] Cardiac CT for the Differentiation of Bicuspid and Tricuspid Aortic Valves: Comparison With Echocardiography and Surgery
    Alkadhi, Hatem
    Leschka, Sebastian
    Trindade, Pedro T.
    Feuchtner, Gudrun
    Stolzmann, Paul
    Plass, Andre
    Baumueller, Stephan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) : 900 - 908
  • [2] Value of cardiac multislice spiral CT for the assessment of degenerative aortic stenosis:: Comparison with echocardiography
    Mahnken, AH
    Koos, R
    Wildberger, JE
    Stanzel, S
    Das, M
    Mühlenbruch, G
    Sinha, AM
    Gunther, RW
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (11): : 1582 - 1588
  • [3] Diagnostic accuracy of bicuspid aortic valve by echocardiography
    Jain, Renuka
    Ammar, Khawaja Afzal
    Kalvin, Lindsey
    Ignatowski, Denise
    Olet, Susan
    Tajik, A. Jamil
    Khandheria, Bijoy K.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (12): : 1932 - 1938
  • [5] Bicuspid noncalcific aortic stenosis: Diagnostic limitations of intraoperative transesophageal echocardiography
    Fontes, ML
    Mathew, J
    Johnson, K
    Rafferty, T
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (01) : 58 - 60
  • [6] Dual-Source Computed Tomography Angiography in Aortic Stenosis: Comparison with Transthoracic Echocardiography
    Yaakup, Nur Adura
    Phuah, Hooi Fang
    Aziz, Yang Faridah Abdul
    Abidin, Imran Zainal
    Sun, Zhonghua
    Ng, Kwan Hoong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (05) : 749 - 755
  • [7] Assessment of aortic valve area on cardiac computed tomography in symptomatic bicuspid aortic stenosis: Utility and differences from Doppler echocardiography
    Kim, Kyu
    Lee, Soo Ji
    Seo, Jiwon
    Suh, Young Joo
    Cho, Iksung
    Hong, Geu-Ru
    Ha, Jong-Won
    Kim, Young Jin
    Shim, Chi Young
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [8] Demonstration of infective endocarditis by cardiac CT and transoesophageal echocardiography: comparison with intra-operative findings
    Koo, Hyun Jung
    Yang, Dong Hyun
    Kang, Joon-Won
    Lee, Joo Yeon
    Kim, Dae-Hee
    Song, Jong-Min
    Kang, Duk-Hyun
    Song, Jae-Kwan
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae-Won
    Lim, Tae-Hwan
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (02) : 199 - 207
  • [9] Value of anatomical aortic valve area using real-time three-dimensional transoesophageal echocardiography in patients with aortic stenosis: a comparison between tricuspid and bicuspid aortic valves
    Machida, Takafumi
    Izumo, Masaki
    Suzuki, Kengo
    Yoneyama, Kihei
    Kamijima, Ryo
    Mizukoshi, Kei
    Takai, Manabu
    Kobayashi, Yasuyuki
    Harada, Tomoo
    Miyake, Fumihiko
    Ohtaki, Eiji
    Nobuoka, Sachihiko
    Matsumoto, Naoki
    Akashi, Yoshihiro J.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (10) : 1120 - 1128
  • [10] Differences in aortic valve area measured on cardiac CT and echocardiography in patients with aortic stenosis
    Choe, Jooae
    Koo, Hyun Jung
    Choi, Se Jin
    Lee, Seung-Ah
    Kim, Dae-Hee
    Song, Jong-Min
    Kang, Duk-Hyun
    Song, Jae-Kwan
    Kang, Joon-Won
    Yang, Dong Hyun
    PLOS ONE, 2023, 18 (01):