Relationship between magnetic field strength and magnetic-resonance-related acoustic noise levels

被引:37
作者
Moelker, A [1 ]
Wielopolski, PA [1 ]
Pattynama, PMT [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Radiol, NL-3000 DR Rotterdam, Netherlands
关键词
acoustic noise; magnetic field strength; sound pressure level;
D O I
10.1007/s10334-003-0005-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The need for better signal-to-noise ratios and resolution has pushed magnetic resonance imaging (MRI) towards high-field MR-scanners for which only little data on MR-related acoustic noise production have been published. The purpose of this study was to validate the theoretical relationship of sound pressure level (SPL) and static magnetic field strength. This is relevant for allowing adequate comparisons of acoustic data of MR systems at various magnetic field strengths. Acoustic data were acquired during various pulse sequences at field strengths of 0.5, 1.0, 1.5 and 2.0 Tesla using the same MRI unit by means of a Helicon rampable magnet. Continuous-equivalent, i.e. time-averaged, linear SPLs and 1/3-octave band frequencies were recorded. Ramping from 0.5 to 1.0 Tesla and from 1.0 to 2.0 Tesla resulted in an SPL increase of 5.7 and 5.2 dB(L), respectively, when averaged over the various pulse sequences. Most of the acoustic energy was in the 1-kHz frequency band, irrespective of magnetic field strength. The relation between field strength and SPL was slightly non-linear, i.e. a slightly less increase at higher field strengths, presumably caused by the elastic properties of the gradient coil encasings.
引用
收藏
页码:52 / 55
页数:4
相关论文
共 21 条
  • [1] *AM NAT STAND, 1995, MEAS SOUND PRESS LEV
  • [2] [Anonymous], 1992, NOISE VIBRATION CONT
  • [3] POTENTIAL HEARING-LOSS RESULTING FROM MR IMAGING
    BRUMMETT, RE
    TALBOT, JM
    CHARUHAS, P
    [J]. RADIOLOGY, 1988, 169 (02) : 539 - 540
  • [4] Analysis of acoustic noise in MRI
    Cho, ZH
    Park, SH
    Kim, JH
    Chung, SC
    Chung, ST
    Chung, JY
    Moon, CW
    Yi, JH
    Sin, CH
    Wong, EK
    [J]. MAGNETIC RESONANCE IMAGING, 1997, 15 (07) : 815 - 822
  • [5] MRI acoustic noise: Sound pressure and frequency analysis
    Counter, SA
    Olofsson, A
    Grahn, HF
    Borg, E
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03): : 606 - 611
  • [6] Elliott MR, 1999, MAGNET RESON MED, V41, P1230, DOI 10.1002/(SICI)1522-2594(199906)41:6<1230::AID-MRM20>3.0.CO
  • [7] 2-1
  • [8] Foster JR, 2000, J MAGN RESON IMAGING, V12, P157, DOI 10.1002/1522-2586(200007)12:1<157::AID-JMRI17>3.0.CO
  • [9] 2-M
  • [10] Characterization and prediction of gradient acoustic noise in MR imagers
    Hedeen, RA
    Edelstein, WA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 7 - 10