Instantaneous phase-angle estimation algorithm under unbalanced voltage-sag conditions

被引:102
作者
Song, HS [1 ]
Nam, K [1 ]
机构
[1] POSTECH Univ, Dept Elect Engn, Pohang 790784, South Korea
关键词
D O I
10.1049/ip-gtd:20000716
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
If a negative sequence is generated by voltage sag and/or unbalance, it appears as an oscillating error in a synchronous reference frame (SRF). In power conditioning equipment, the exact value of a positive sequence is needed to achieve the unity power factor and constant output voltage, whereas the exact value of a negative sequence is needed for unbalance compensation. To measure the positive sequence separately from the negative sequence, a low pass or notch filter having a narrow bandwidth is normally used. However, such a filter causes a lot of phase delay, thus the response time of the system tends to be lengthened. A method of estimating the positive- and the negative-sequence voltages separately is presented, without a significant delay, by utilising the weighted least-squares estimation (WLSE) method with the covariance resetting technique. A frequency update law is also proposed to accommodate the frequency varying environments. The authors demonstrate through simulation and experiment the superior performance of the proposed scheme in measuring the positive- and the negative-sequence voltages at the time of abrupt transition. This method can be applied to uninterruptable power supplies CUPS), pulsewidth modulation (PWM) AC/DC converters, active filters, AC voltage compensators etc.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 10 条
[1]  
Beeman D., 1955, IND POWER SYSTEM HDB
[2]  
Enjeti P. N., 1993, IEEE Transactions on Power Electronics, V8, P493, DOI 10.1109/63.261020
[3]   A DIGITAL RECURSIVE MEASUREMENT SCHEME FOR ONLINE TRACKING OF POWER-SYSTEM HARMONICS [J].
GIRGIS, AA ;
CHANG, WB ;
MAKRAM, EB .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (03) :1153-1160
[4]   Statcom controls for operation with unbalanced voltages [J].
Hochgraf, C ;
Lasseter, RH .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (02) :538-544
[5]  
Kim HS, 1998, IEEE POWER ELECTRON, P503, DOI 10.1109/PESC.1998.701945
[6]   Voltage sags: Their impact on the utility and industrial customers [J].
Melhorn, CJ ;
Davis, TD ;
Beam, GE .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (03) :549-558
[7]  
S??derstr??m T., 1989, SYSTEM IDENTIFICATIO
[8]   An iterative technique for fast and accurate measurement of power system frequency [J].
Sidhu, TS ;
Sachdev, MS .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (01) :109-115
[9]   Dual current control scheme for PWM converter under unbalanced input voltage conditions [J].
Song, HS ;
Nam, K .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1999, 46 (05) :953-959
[10]   Characterization of voltage sags in industrial distribution systems [J].
Yalcinkaya, G ;
Bollen, MHJ ;
Crossley, PA .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (04) :682-688