Adjunctive triamcinolone acetonide for Ahmed glaucoma valve implantation: a randomized clinical trial

被引:12
作者
Yazdani, Shahin [1 ,2 ]
Doozandeh, Azadeh [2 ]
Pakravan, Mohammad [2 ]
Ownagh, Vahid [2 ]
Yaseri, Mehdi [3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Ocular Tissue Engn Res Ctr, Tehran, Iran
[2] Shahid Beheshti Univ Med Sci, Ophthalm Res Ctr, Tehran, Iran
[3] Univ Tehran Med Sci, Dept Epidemiol & Biostat, Tehran, Iran
关键词
Ahmed glaucoma valve; Hypertensive phase; Intraocular pressure; Triamcinolone; MITOMYCIN-C; HYPERTENSIVE PHASE;
D O I
10.5301/ejo.5000892
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effect of intraoperative sub-Tenon injection of triamcinolone acetonide (TA) as an adjunct to Ahmed glaucoma valve (AGV) implantation. Methods: In this triple-blind randomized clinical trial, 104 eyes with refractory glaucoma were randomly assigned to conventional AGV (non-TA group) or AGV with adjunctive triamcinolone (TA group). In the TA group, 10 mg TA was injected in the sub-Tenon space around the AGV plate intraoperatively. Patients were followed for 1 year. The main outcome measure was intraocular pressure (IOP). Other outcome measures included best-corrected visual acuity (BCVA), occurrence of hypertensive phase (HP), peak IOP, number of antiglaucoma medications, and complications. Results: A total of 90 patients were included in the final analysis. Mean IOP was lower in the TA group at most follow-up visits; however, the difference was statistically significant only at the first month (p = 0.004). -Linear mixed model showed that mean IOP was 1.5 mm Hg lower in the TA group throughout the study period (p = 0.006). Peak postoperative IOP was significantly lower in the TA group (19.3 +/- 4.8 mm Hg versus 29 +/- 9.2 mm Hg, p = 0.032). Rates of success (defined as 6 < IOP < 21 mm Hg) were similar in both groups at 12 months. There was no difference in the occurrence of the HP between the 2 groups (p = 0.123). Loss of BCVA > 2 lines was more common in the non-TA group (p = 0.032). Conclusions: Adjunctive intraoperative TA injection during AGV implantation can blunt peak IOP levels and reduce mean IOP up to 1 year. Visual outcomes also seem to be superior to standard surgery.
引用
收藏
页码:411 / 416
页数:6
相关论文
共 18 条
[1]  
Assaad M H, 1999, Curr Opin Ophthalmol, V10, P147, DOI 10.1097/00055735-199904000-00012
[2]   A clinical study of the Ahmed glaucoma valve implant in advanced glaucoma [J].
Ayyala, RS ;
Zurakowski, D ;
Smith, JA ;
Monshizadeh, R ;
Netland, PA ;
Richards, DW ;
Layden, WE .
OPHTHALMOLOGY, 1998, 105 (10) :1968-1976
[3]   Intraocular concentration and pharmacokinetics of triamcinolone acetonide after a single intravitreal injection [J].
Beer, PM ;
Bakri, SJ ;
Singh, RJ ;
Liu, WG ;
Peters, GB ;
Miller, M .
OPHTHALMOLOGY, 2003, 110 (04) :681-686
[4]   The Ahmed Versus Baerveldt Study One-Year Treatment Outcomes [J].
Christakis, Panos G. ;
Kalenak, Jeffrey W. ;
Zurakowski, David ;
Tsai, James C. ;
Kammer, Jeffrey A. ;
Harasymowycz, Paul J. ;
Ahmed, Iqbal I. K. .
OPHTHALMOLOGY, 2011, 118 (11) :2180-2189
[5]   Efficacy and safety of adjunctive mitomycin C during ahmed glaucoma valve implantation - A prospective Randomized clinical trial [J].
Costa, VP ;
Azuara-Blanco, A ;
Netland, PA ;
Lesk, MR ;
Arcieri, ES .
OPHTHALMOLOGY, 2004, 111 (06) :1071-1076
[6]  
Fan Gaskin Jennifer C, 2014, J Curr Glaucoma Pract, V8, P37, DOI 10.5005/jp-journals-10008-1159
[7]   Pro-Inflammatory Cytokines in Glaucomatous Aqueous and Encysted Molteno Implant Blebs and Their Relationship to Pressure [J].
Freedman, Jeffrey ;
Iserovich, Pavel .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) :4851-4855
[8]  
Kook MS, 2000, OPHTHALMIC SURG LAS, V31, P100
[9]   The effect of adjunctive mitomycin C in Ahmed glaucoma valve implantation [J].
Kurnaz, E ;
Kubaloglu, A ;
Yilmaz, Y ;
Koytak, A ;
Özertürk, Y .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (01) :27-31
[10]   Evaluation of the hypertensive phase after insertion of the Ahmed Glaucoma Valve [J].
Nouri-Mahdavi, K ;
Caprioli, J .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) :1001-1008