Study of point-supported glass breakage behavior with varying point-covered areas under thermal loading

被引:5
|
作者
Lu, Wei [1 ]
Chen, Haodong [1 ]
Wang, Yu [2 ]
Duan, Qiangling [1 ]
Jiang, Lin [1 ]
Wang, Qingsong [1 ]
Sun, Jinhua [1 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230027, Anhui, Peoples R China
[2] Univ Edinburgh, BRE Ctr Fire Safety Engn, Sch Engn, Edinburgh EH9 3JL, Midlothian, Scotland
基金
中国博士后科学基金;
关键词
Point-supported glazing; Fire; Point-covered area; First breakage time; Stress field distribution; WINDOW GLASS; FRACTURE-BEHAVIOR; RADIANT EXPOSURE; FIRE CONDITIONS; CORNER FIRES; PERFORMANCE; SINGLE; TRANSMISSION; ENCLOSURE; FACADES;
D O I
10.1016/j.ijthermalsci.2018.05.045
中图分类号
O414.1 [热力学];
学科分类号
摘要
Point-supported glazing assemblies are widely used in modern buildings for aesthetic elegance, as well as for economic reasons. However, the formation of vents caused by glass breakage could aggravate ventilation controlled compartment fires. The point-covered area generally varies and may constitute potential fire hazards. Accordingly, it is necessary to investigate the fire performance and breakage mechanisms in various point covered areas. In this study, a total of 12 tests, including three various point-covered area glazing, were heated by a 200 x 200 mm(2) pool fire. The breakage time, glass surface and air temperatures, incident heat flux, and crack initiation and final fall out ratio were obtained. The critical conditions for the three aforementioned various point-covered area glazing were determined. The reference breakage times, t(r), which were calculated by assigning a failure probability of 0.1 to the two-parameter Weibull distribution were 119, 140, and 166 s. It was established that a relatively small point-covered area glazing can survive longer; the smaller the point-covered area was, the larger the final fallout ratio of glazing assemblies will be. Numerical simulations were performed to investigate the stress distribution on the glass pane, with breakage times well predicted. Accordingly, these results have implications on the fire resistance design for point-supported glazing assemblies.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 23 条
  • [1] Investigation of the thermal response and breakage mechanism of point-supported glass facade under wind load
    Lu, Wei
    Wang, Yu
    Chen, Haodong
    Jiang, Lin
    Duan, Qiangling
    Li, Mi
    Wang, Qingsong
    Sun, Jinhua
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 186 : 635 - 643
  • [2] Analysis on loading capacity of six point-supported glass panel
    Zhao, Min-Xing
    Shi, Yong-Jiu
    Wang, Yuan-Qing
    ADVANCES IN STRUCTURAL ENGINEERING:THEORY AND APPLICATIONS VOLS 1 AND 2, 2006, : 477 - 482
  • [3] Fatigue Performance of Point-supported Insulated Tempered Glass Panels Under Cyclic Loading
    Li H.
    Shu G.
    Lu R.
    Li Y.
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2017, 25 (03): : 546 - 557
  • [4] Fatigue tests of point-supported tempered and laminated glass panels under cyclic loading
    Shu, Ganping
    Lu, Ruihua
    Li, Haiyun
    Shi, Yongjiu
    Wang, Yuanqing
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2012, 42 (04): : 706 - 712
  • [5] Effects of fixing point positions on thermal response of four point-supported glass facades
    Wang, Yu
    Wang, Qingsong
    Sun, Jinhua
    He, Linghui
    Liew, K. M.
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 73 : 235 - 246
  • [6] Performance analysis of point-supported glass panel subjected to blast and impact loading
    Ge, Jie
    Li, Guoqiang
    Chen, Suwen
    Zhendong Ceshi Yu Zhenduan/Journal of Vibration, Measurement and Diagnosis, 2012, 32 (03): : 505 - 509
  • [7] Analysis on the bending behavior of point-supported insulating-laminated glass panel
    Institute of Glass and Metal Structure for Architecture, Tsinghua University, Beijing 100084, China
    不详
    Wuhan Ligong Daxue Xuebao, 2008, 5 (91-94+108):
  • [8] Thermal response and resistance optimization of various types of point-supported glass facades
    Lu, Wei
    Duan, Qiangling
    Chen, Haodong
    Li, Huang
    Liu, Yujun
    Wang, Qingsong
    Sun, Jinhua
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 224 : 610 - 621
  • [9] Experimental study on failure mechanism of point-supported tempered glass panels under fire conditions
    Yin, Fei
    Liu, Meiyu
    Bai, Yin
    Zhai, Jianlei
    Zhang, Youzhen
    Yang, Lu
    STRUCTURES, 2021, 30 : 495 - 502
  • [10] Method of point-supported insulating-laminated glass unit bending loading design
    Institute of Glass and Metal Structure for Architecture, Tsinghua University, Beijing 100084, China
    不详
    Jianzhu Cailiao Xuebao, 2009, 6 (756-760):