Ten-year clinical outcomes after sirolimus-eluting stent implantation: Impact of an in-stent restenosis target lesion

被引:12
作者
Miura, Katsuya [1 ]
Kadota, Kazushige [1 ]
Habara, Seiji [1 ]
Miyawaki, Hiroshi [1 ]
Shimada, Takenobu [1 ]
Ohya, Masanobu [1 ]
Amano, Hidewo [1 ]
Izawa, Yu [1 ]
Hyodo, Yusuke [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Tada, Takeshi [1 ]
Tanaka, Hiroyuki [1 ]
Fuku, Yasushi [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiol, 1-1-1 Miwa, Kurashiki, Okayama 7100052, Japan
关键词
BARE-METAL STENTS; FOLLOW-UP; THROMBOSIS; PACLITAXEL; REGISTRY; EVENTS; REVASCULARIZATION; TRIALS; LABEL; RISK;
D O I
10.1016/j.ahj.2016.02.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Little is known about the long-term outcomes after first-generation sirolimus-eluting stent (SES) implantation. We aimed to investigate the clinical outcomes up to 10 years after SES implantation. Methods The study population comprised 342 patients (504 lesions) who underwent SES implantation between January 2002 and December 2004. The median duration of follow-up was 3816 days (interquartile range [Q1-Q3], 3,7053,883 days). Results The cumulative event rate of definite stent thrombosis was 3.9%. The cumulative rate of target lesion revascularization (TLR) at 1, 5, and 10 years was 8.7%, 18.8%, and 31.1%, respectively, and the annual rate of TLR was 3.1%. Clinically driven TLR occurred at relatively constant rate during 10 years (2.0% per year). In a multivariate analysis, higher body mass index, hemodialysis, in-stent restenosis (ISR) target lesion, and total stent length >30 mm were independent risk factors of TLR within 5 years. An independent risk factor of TLR beyond 5 years was ISR target lesion. Conclusions Late TLR after SES implantation is a long-term hazard, lasting up to 10 years. The ISR target lesion is a risk factor of TLR during 10 years.
引用
收藏
页码:47 / 55
页数:9
相关论文
共 30 条
[1]   Stent-Related Cardiac Events Beyond Three Years After Implantation of the Sirolimus-Eluting Stent (from the EVASTENT Patients) [J].
Barone-Rochette, Gilles ;
Foote, Alison ;
Motreff, Pascal ;
Vanzetto, Gerald ;
Quesada, Jean-Louis ;
Danchin, Nicolas ;
Machecourt, Jacques .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (10) :1401-1407
[2]   5-Year Clinical Outcomes After Sirolimus-Eluting Stent Implantation Insights From a Patient-Level Pooled Analysis of 4 Randomized Trials Comparing Sirolimus-Eluting Stents With Bare-Metal Stents [J].
Caixeta, Adriano ;
Leon, Martin B. ;
Lansky, Alexandra J. ;
Nikolsky, Eugenia ;
Aoki, Jiro ;
Moses, Jeffrey W. ;
Schofer, Joachim ;
Morice, Marie-Claude ;
Schampaert, Erick ;
Kirtane, Ajay J. ;
Popma, Jeffrey J. ;
Parise, Helen ;
Fahy, Martin ;
Mehran, Roxana .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (10) :894-902
[3]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[4]   Drug-eluting stent thrombosis -: Results from the Multicenter Spanish registry ESTROFA (Estudio ESpanol sobre TROmbosis de stents FArmacoactivos) [J].
de la Torre-Hernandez, Jos M. ;
Alfonso, Fernando ;
Hernandez, Felipe ;
Elizaga, Jaime ;
Sanmartin, Marcelo ;
Pinar, Eduardo ;
Lozano, Inigo ;
Vazquez, Jose M. ;
Botas, Javier ;
Perez de Prado, Armando ;
Hernandez, Jose M. ;
Sanchis, Juan ;
Ruiz Nodar, Juan M. ;
Gomez-Jaume, Alfredo ;
Larman, Mariano ;
Diarte, Jose A. ;
Rodriguez-Collado, Javier ;
Rumoroso, Jose R. ;
Lopez-Minguez, Jose R. ;
Mauri, Josepa .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) :986-990
[5]   Late Restenosis After Paclitaxel-Coated Balloon Angioplasty Occurs in Patients With Drug-Eluting Stent Restenosis [J].
Habara, Seiji ;
Kadota, Kazushige ;
Shimada, Takenobu ;
Ohya, Masanobu ;
Amano, Hidewo ;
Izawa, Yu ;
Kubo, Shunsuke ;
Hyodo, Yusuke ;
Otsuru, Suguru ;
Hasegawa, Daiji ;
Tada, Takeshi ;
Tanaka, Hiroyuki ;
Fuku, Yasushi ;
Goto, Tsuyoshi ;
Mitsudo, Kazuaki .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (01) :14-22
[6]  
Jensen LO, 2010, EUROINTERVENTION, V5, P898, DOI 10.4244/
[7]   Very Late Stent Thrombosis and Late Target Lesion Revascularization After Sirolimus-Eluting Stent Implantation Five-Year Outcome of the j-Cypher Registry [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Nakagawa, Yoshihisa ;
Kawai, Kazuya ;
Miyazaki, Shunichi ;
Muramatsu, Toshiya ;
Shiode, Nobuo ;
Namura, Masanobu ;
Sone, Takahito ;
Oshima, Shigeru ;
Nishikawa, Hideo ;
Hiasa, Yoshikazu ;
Hayashi, Yasuhiko ;
Nobuyoshi, Masakiyo ;
Mitudo, Kazuaki .
CIRCULATION, 2012, 125 (04) :584-U111
[8]   Comparisons of Baseline Demographics, Clinical Presentation, and Long-Term Outcome Among Patients With Early, Late, and Very Late Stent Thrombosis of Sirolimus-Eluting Stents Observations From the Registry of Stent Thrombosis for Review and Reevaluation (RESTART) [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Kozuma, Ken ;
Honda, Yasuhiro ;
Kume, Teruyoshi ;
Aizawa, Tadanori ;
Mitsudo, Kazuaki ;
Miyazaki, Shunichi ;
Yamaguchi, Tetsu ;
Hiyoshi, Emi ;
Nishimura, Eizo ;
Isshiki, Takaaki .
CIRCULATION, 2010, 122 (01) :52-U120
[9]   Antiplatelet Therapy and Stent Thrombosis After Sirolimus-Eluting Stent Implantation [J].
Kimura, Takeshi ;
Morimoto, Takeshi ;
Nakagawa, Yoshihisa ;
Tamura, Toshihiro ;
Kadota, Kazushige ;
Yasumoto, Hitoshi ;
Nishikawa, Hideo ;
Hiasa, Yoshikazu ;
Muramatsu, Toshiya ;
Meguro, Taiichiro ;
Inoue, Naoto ;
Honda, Hidehiko ;
Hayashi, Yasuhiko ;
Miyazaki, Shunichi ;
Oshima, Shigeru ;
Honda, Takashi ;
Shiode, Nobuo ;
Namura, Masanobu ;
Sone, Takahito ;
Nobuyoshi, Masakiyo ;
Kita, Toru ;
Mitsudo, Kazuaki .
CIRCULATION, 2009, 119 (07) :987-U120
[10]   Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis [J].
Köster, R ;
Vieluf, D ;
Kiehn, M ;
Sommerauer, M ;
Kähler, J ;
Baldus, S ;
Meinertz, T ;
Hamm, CW .
LANCET, 2000, 356 (9245) :1895-1897