Embedded cooling with 3D manifold for vehicle power electronics application: Single-phase thermal-fluid performance

被引:106
作者
Jung, Ki Wook [1 ]
Kharangate, Chirag R. [2 ]
Lee, Hyoungsoon [3 ]
Palko, James [4 ]
Zhou, Feng [5 ]
Asheghi, Mehdi [1 ]
Dede, Ercan M. [5 ]
Goodson, Kenneth E. [1 ]
机构
[1] Stanford Univ, Mech Engn Dept, Stanford, CA 94305 USA
[2] Case Western Reserve Univ, Mech & Aerosp Engn Dept, Cleveland, OH 44106 USA
[3] Chung Ang Univ, Sch Mech Engn, Seoul 06974, South Korea
[4] Univ Calif Merced, Merced, CA 95343 USA
[5] Toyota Res Inst North Amer, Ann Arbor, MI 48105 USA
基金
美国国家科学基金会;
关键词
Embedded microchannel; 3D manifold; Monolithic microcooler; Conjugate thermal-fluidic numerical simulations; Single-phase water cooling experiments; MICROCHANNEL; OPTIMIZATION;
D O I
10.1016/j.ijheatmasstransfer.2018.10.108
中图分类号
O414.1 [热力学];
学科分类号
摘要
Single-phase thermal-fluidic performance of an embedded silicon microchannel cold-plate (25 parallel channels: 75 mu m x 150 mu m) with a 3-D liquid distribution manifold (6 inlets: 700 mu m x 150 mu m) and vapor extraction conduits, is investigated using water as working fluid. A 3D manifold is fabricated from silicon and bonded to a silicon microchannel substrate to form a monolithic microcooler (mu-cooler). A metal serpentine bridge (5(2) mm(2) of footprint) and multiple resistance temperature detectors (RTDs) are used for electrical Joule-heating and thermometry, respectively. The experimental results for maximum and average temperatures of the chip, pressure drop, thermal resistance (as low as 0.68 K/W), average heat transfer coefficient (similar to 30,000-50,000 W/m(2) K) for flow rates of 0.03, 0.06 and 0.1 l/min and heat fluxes of 60, 100 and 250 W/cm(2) are reported. The embedded microchannel-3D manifold mu-cooler device is capable of removing 250 W/cm(2) at a maximum temperature of 90 degrees C with less than 3 kPa pressure drop for a flow rate of 0.1 l/min. The results from conjugate thermal-fluidic numerical simulations agree well with the experimental data over the wide range of heat fluxes and flow conditions. The numerical simulation results also hint at the possibility of removing up to similar to 850 W/cm(2) using single-phase water at a maximum temperature of 166 degrees C at the same pressure drop and flow rate. This offers a very attractive strategy/option for cooling of high heat flux power electronics using single-phase water. (C) 2018 Published by Elsevier Ltd.
引用
收藏
页码:1108 / 1119
页数:12
相关论文
共 25 条
  • [1] [Anonymous], 2010, THESIS
  • [2] [Anonymous], 2006, EL EL TECHN TEAM ROA
  • [3] Numerical modeling and thermal optimization of a single-phase flow manifold-microchannel plate heat exchanger
    Arie, M. A.
    Shooshtari, A. H.
    Dessiatoun, S. V.
    Al-Hajri, E.
    Ohadi, M. M.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 478 - 489
  • [4] Arie M.A., 2012, ASME 2012 INT MECH E, P209
  • [5] Arie MA, 2014, INTSOC CONF THERMAL, P807, DOI 10.1109/ITHERM.2014.6892364
  • [6] Bae DG, 2017, INTERSOC C THERMAL T, P466
  • [7] Bar-Cohen A., 2013, J NANOTECHNOL ENG ME, V4
  • [8] Numerical investigation and sensitivity analysis of manifold microchannel coolers
    Boteler, Lauren
    Jankowski, Nicholas
    McCluskey, Patrick
    Morgan, Brian
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 7698 - 7708
  • [9] Characterization of hierarchical manifold microchannel heat sink arrays under simultaneous background and hotspot heating conditions
    Drummond, Kevin P.
    Back, Doosan
    Sinanis, Michael D.
    Janes, David B.
    Peroulis, Dimitrios
    Weibel, Justin A.
    Garimella, Suresh V.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 126 : 1289 - 1301
  • [10] Drummond KP, 2016, INTERSOC C THERMAL T, P307, DOI 10.1109/ITHERM.2016.7517565