Inertia Compensation Control of a One-Degree-of-Freedom Exoskeleton for Lower-Limb Assistance: Initial Experiments

被引:101
作者
Aguirre-Ollinger, Gabriel [1 ]
Colgate, J. Edward [2 ]
Peshkin, Michael A. [2 ]
Goswami, Ambarish [3 ]
机构
[1] Univ Technol Sydney, Sch Elect Mech & Mechtron Syst, Broadway, NSW 2007, Australia
[2] Northwestern Univ, Dept Mech Engn, Evanston, IL 60208 USA
[3] Honda Res Inst, Mountain View, CA 94041 USA
关键词
Admittance control; exoskeleton; rehabilitation robotics; ENERGETICS; WALKING; ROBOT; POWER; MASS;
D O I
10.1109/TNSRE.2011.2176960
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new method of lower-limb exoskeleton control aimed at improving the agility of leg-swing motion is presented. In the absence of control, an exoskeleton's mechanism usually hinders agility by adding mechanical impedance to the legs. The uncompensated inertia of the exoskeleton will reduce the natural frequency of leg swing, probably leading to lower step frequency during walking as well as increased metabolic energy consumption. The proposed controller emulates inertia compensation by adding a feedback loop consisting of low-pass filtered angular acceleration multiplied by a negative gain. This gain simulates negative inertia in the low-frequency range. The resulting controller combines two assistive effects: increasing the natural frequency of the lower limbs and performing net work per swing cycle. The controller was tested on a statically mounted exoskeleton that assists knee flexion and extension. Subjects performed movement sequences, first unassisted and then using the exoskeleton, in the context of a computer-based task resembling a race. In the exoskeleton's baseline state, the frequency of leg swing and the mean angular velocity were consistently reduced. The addition of inertia compensation enabled subjects to recover their normal frequency and increase their selected angular velocity. The work performed by the exoskeleton was evidenced by catch trials in the protocol.
引用
收藏
页码:68 / 77
页数:10
相关论文
共 23 条
  • [1] A one-degree-of-freedom assistive exoskeleton with inertia compensation: the effects on the agility of leg swing motion
    Aguirre-Ollinger, G.
    Colgate, J. E.
    Peshkin, M. A.
    Goswami, A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H3) : 228 - 245
  • [2] Aguirre-Ollinger G., 2009, Active Impedance Control of a Lower-Limb Assistive Exoskeleton
  • [3] Active-impedance control of a lower-limb Assistive exoskeleton
    Aguirre-Ollinger, Gabriel
    Colgate, J. Edward
    Peshkin, Michael A.
    Goswami, Ambarish
    [J]. 2007 IEEE 10TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, VOLS 1 AND 2, 2007, : 188 - +
  • [4] Aguirre-Ollinger G, 2007, 2007 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-9, P1944
  • [5] Design of an active one-degree-of-freedom lower-limb exoskeleton with inertia compensation
    Aguirre-Ollinger, Gabriel
    Colgate, J. Edward
    Peshkin, Michael A.
    Goswami, Ambarish
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2011, 30 (04) : 486 - 499
  • [6] Robot Assisted Gait Training With Active Leg Exoskeleton (ALEX)
    Banala, Sai K.
    Kim, Seok Hun
    Agrawal, Sunil K.
    Scholz, John P.
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2009, 17 (01) : 2 - 8
  • [7] The effects of adding mass to the legs on the energetics and biomechanics of walking
    Browning, Raymond C.
    Modica, Jesse R.
    Kram, Rodger
    Goswami, Ambarish
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (03) : 515 - 525
  • [8] Lower extremity exoskeletons and active orthoses: Challenges and state-of-the-art
    Dollar, Aaron M.
    Herr, Hugh
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2008, 24 (01) : 144 - 158
  • [9] A physiologist's perspective on robotic exoskeletons for human locomotion
    Ferris, Daniel P.
    Sawicki, Gregory S.
    Daley, Monica A.
    [J]. INTERNATIONAL JOURNAL OF HUMANOID ROBOTICS, 2007, 4 (03) : 507 - 528
  • [10] Ferris Daniel P, 2005, Top Spinal Cord Inj Rehabil, V11, P34