Comparison between predicted and actual energy performance for winter heating in high-performance residential buildings in the Lombardy region (Italy)

被引:44
作者
Dall'O', Giuliano [1 ]
Sarto, Luca [1 ]
Galante, Annalisa [1 ]
Pasetti, Giulia [1 ]
机构
[1] Politecn Milan, BEST Bldg Environm Sci & Technol Dept, I-20133 Milan, Italy
关键词
Energy certification; Energy performance monitoring; Low energy use buildings; Residential buildings;
D O I
10.1016/j.enbuild.2011.11.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The energy certification of buildings implemented in the Member States of the EU with the transposition of Energy Performance Building Directive (EPBD) has stimulated the market for high-performance buildings, normally classified as A and A+. Such energy performance, however, is evaluated based on a theoretical calculation model that defines standard operating conditions. In Italy, as in most EU countries, performance assessments are not carried out under real operating conditions. The Lombardy region is a leading player in the field of social housing. In order to demonstrate transparency to the customer, the BEST Department of Politecnico di Milano was instructed to conduct a comparative evaluation between the actual and normalised energy performance of a high performance building located in Milan. The study showed that the real performance, calculated using data from three selected flats, was consistent with that calculated during the certification procedure. However real energy consumption is different even in identical flats, due to different behaviours of the users. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 7 条
[1]   Practical versus theoretical domestic energy consumption for space heating [J].
Audenaert, A. ;
Briffaerts, K. ;
Engels, L. .
ENERGY POLICY, 2011, 39 (09) :5219-5227
[2]   Application of energy rating methods to the existing building stock: Analysis of some residential buildings in Turin [J].
Ballarini, Ilaria ;
Corrado, Vincenzo .
ENERGY AND BUILDINGS, 2009, 41 (07) :790-800
[3]   Comparison between measured and calculated energy performance for dwellings in a summer dominant environment [J].
Fokaides, Paris A. ;
Maxoulis, Christos N. ;
Panayiotou, Gregoris P. ;
Neophytou, Marina K-A ;
Kalogirou, Soteris A. .
ENERGY AND BUILDINGS, 2011, 43 (11) :3099-3105
[4]  
ISO, 137902008 ISO
[5]  
Regione Lombardia-CESTEC, PIAN AZ EN REG LOMB
[6]   Energy performance building evaluation in Mediterranean countries: Comparison between software simulations and operating rating simulation [J].
Tronchin, Lamberto ;
Fabbri, Kristian .
ENERGY AND BUILDINGS, 2008, 40 (07) :1176-1187
[7]  
UNITS 11300-2, 113002 UNI TS