A new chelation induced enhanced fluorescence-type optical sensor based on parared immobilized in a plasticized PVC membrane for selective determination of Zn(II) ions

被引:33
作者
Shamsipur, Mojtaba [2 ]
Poursaberi, Tahereh [1 ]
Hassanisadi, Mostafa [1 ]
Rezapour, Morteza [1 ]
Nourmohammadian, Farahnaz [3 ]
Alizadeh, Kamal [4 ]
机构
[1] RIPI, Tehran, Iran
[2] Razi Univ, Dept Chem, Kermanshah, Iran
[3] Inst color Sci & technol, Dept organ colorants, Tehran, Iran
[4] Lorestan Univ, Dept Chem, Khorramabad, Iran
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2012年 / 161卷 / 01期
关键词
Optode membrane; Zinc; Fluorescence enhancement; Parared; OPTODE MEMBRANE; FLOW-INJECTION; METAL-IONS; ZINC; CADMIUM; ELECTRODE; FLUOROIONOPHORE; CHEMOSENSORS; FLUOROPHORE; CALCIUM;
D O I
10.1016/j.snb.2011.12.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical sensor based on fluorescence enhancement of a disperse azo dye (parared, PR) immobilized in a plasticized PVC membrane for the determination of Zn2+ ions has been developed. The optode displays a calibration response for Zn2+ ions over the concentration range of 5.0 x 10(-3)-1.0 x 10(-6) M. The response characteristics of the sensor including its response mechanism, membrane composition, pH of solution, repeatability and reproducibility, response time, regeneration and selectivity are discussed in detail. The optode was applied as an indicator electrode in titration of zinc ions and also to the determination of zinc in zinc sulfate tablets and zinc oxide cream. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1080 / 1087
页数:8
相关论文
共 92 条
  • [1] Development of an optical sensor for determination of zinc by application of PC-ANN
    Abbasitabar, Fatemeh
    Zare-Shahabadi, Vail
    Shamsipur, Mojtaba
    Akhond, Morteza
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (01): : 181 - 186
  • [2] CHELATION-ENHANCED FLUORESCENCE OF ANTHRYLAZAMACROCYCLE CONJUGATE PROBES IN AQUEOUS-SOLUTION
    AKKAYA, EU
    HUSTON, ME
    CZARNIK, AW
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1990, 112 (09) : 3590 - 3593
  • [3] Determination of irbesartan in the presence of hydrochlorothiazide by derivative spectrophotometry
    Albero, I
    Ródenas, V
    García, S
    Sánchez-Pedreño, C
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (1-2) : 299 - 305
  • [4] Determination of zinc (II) in pharmaceuticals based on a flow-through bulk optode
    Albero, MI
    Ortuño, JA
    García, MS
    Sánchez-Pedreño, C
    Expósito, R
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) : 779 - 786
  • [5] PREPARATION OF NEUTRAL IONOPHORES FOR ALKALI AND ALKALINE-EARTH METAL CATIONS AND THEIR APPLICATION IN ION-SELECTIVE MEMBRANE ELECTRODES
    AMMANN, D
    BISSIG, R
    GUGGI, M
    PRETSCH, E
    SIMON, W
    BOROWITZ, IJ
    WEISS, L
    [J]. HELVETICA CHIMICA ACTA, 1975, 58 (06) : 1535 - 1548
  • [6] NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM
    ANKER, P
    WIELAND, E
    AMMANN, D
    DOHNER, RE
    ASPER, R
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (13) : 1970 - 1974
  • [7] [Anonymous], 1981, ALDRICH LIB INFRARED
  • [8] RELEASE OF ENDOGENOUS ZN-2+ FROM BRAIN-TISSUE DURING ACTIVITY
    ASSAF, SY
    CHUNG, SH
    [J]. NATURE, 1984, 308 (5961) : 734 - 736
  • [9] Ault S., 1998, TECHNIQUES EXPT ORGA, P505
  • [10] OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES
    BAKKER, E
    XU, AP
    PRETSCH, E
    [J]. ANALYTICA CHIMICA ACTA, 1994, 295 (03) : 253 - 262