Relevance of MTF and NPS in Quantitative CT: Towards Developing a Predictable Model of Quantitative Performance

被引:6
作者
Chen, Baiyu [1 ,2 ]
Richard, Samuel [2 ,3 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Med Phys Grad Program, Durham, NC 27705 USA
[2] Duke Univ, Carl E Ravin Adv Imaging Lab, Durham, NC 27705 USA
[3] Duke Univ, Dept Radiol, Durham, NC 27705 USA
[4] Duke Univ, Dept Phys Biomed Engn & Elect & Comp Engn, Durham, NC 27705 USA
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
CT volume quantification; Precision prediction; TTF; NPS; Estimability;
D O I
10.1117/12.913219
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The quantification of lung nodule volume based on CT images provides valuable information for disease diagnosis and staging. However, the precision of the quantification is protocol, system, and technique dependent and needs to be evaluated for each specific case. To efficiently investigate the quantitative precision and find an optimal operating point, it is important to develop a predictive model based on basic system parameters. In this study, a Fourier-based metric, the estimability index (e') was proposed as such a predictor, and validated across a variety of imaging conditions. To first obtain the ground truth of quantitative precision, an anthropomorphic chest phantom with synthetic spherical nodules were imaged on a 64 slice CT scanner across a range of protocols (five exposure levels and two reconstruction algorithms). The volumes of nodules were quantified from the images using clinical software, with the precision of the quantification calculated for each protocol. To predict the precision, e' was calculated for each protocol based on several Fourier-based figures of merit, which modeled the characteristic of the quantitation task and the imaging condition (resolution, noise, etc.) of a particular protocol. Results showed a strong correlation (R-2=0.92) between the measured and predicted precision across all protocols, indicating e' as an effective predictor of the quantitative precision. This study provides a useful framework for quantification-oriented optimization of CT protocols.
引用
收藏
页数:7
相关论文
共 4 条
[1]   Applications of the Repeatability of Quantitative Imaging Biomarkers: A Review of Statistical Analysis of Repeat Data Sets [J].
Barnhart, Huiman X. ;
Barboriak, Daniel P. .
TRANSLATIONAL ONCOLOGY, 2009, 2 (04) :231-235
[2]  
Chen B., QUANTITATIVE CT TECH, V7622
[3]   Noncalcified Lung Nodules: Volumetric Assessment with Thoracic CT [J].
Gavrielides, Marios A. ;
Kinnard, Lisa M. ;
Myers, Kyle J. ;
Petrick, Nicholas .
RADIOLOGY, 2009, 251 (01) :26-37
[4]   Quantitative breast tomosynthesis: From detectability to estimability [J].
Richard, Samuel ;
Samei, Ehsan .
MEDICAL PHYSICS, 2010, 37 (12) :6157-6165