Evaluation of Brain and Head and Neck Tumors with 4D Contrast-Enhanced MR Angiography at 3T

被引:9
作者
Nishimura, S. [1 ]
Hirai, T. [1 ]
Shigematsu, Y. [1 ]
Kitajima, M. [1 ]
Morioka, M. [2 ]
Kai, Y. [2 ]
Minoda, R. [3 ]
Uetani, H. [1 ]
Murakami, R. [4 ]
Yamashita, Y. [1 ]
机构
[1] Kumamoto Univ, Dept Diagnost Radiol, Grad Sch Med Sci, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Dept Neurosurg, Grad Sch Med Sci, Kumamoto 8608556, Japan
[3] Kumamoto Univ, Dept Otolaryngol Head & Neck Surg, Grad Sch Med Sci, Kumamoto 8608556, Japan
[4] Kumamoto Univ, Dept Med Imaging, Fac Life Sci, Kumamoto 8608556, Japan
关键词
PARAGANGLIOMAS; KEYHOLE; COMBINATION;
D O I
10.3174/ajnr.A2819
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Systematic assessment of brain and head and neck tumors with 4D-CE-MRA at 3T has not been investigated. The purpose of this study was to test the hypothesis that 4D-CE-MRA at 3T can replace DSA in the identification of feeding arteries and tumor stain to plan interventional procedures in hypervascular brain and head and neck tumors. MATERIALS AND METHODS: Fifteen consecutive patients with brain and head and neck tumors underwent 4D-CE-MRA at 3T and DSA. 4D-CE-MRA combined randomly segmented central k-space ordering, keyhole imaging, SENSE, and half-Fourier imaging. We obtained 30 dynamic scans every 1.9 seconds at an acquired spatial resolution of 0.9 x 0.9 x 1.5 mm; the matrix was 256 x 256. Two independent observers inspected the 4D-CE-MRA images for the main arterial feeders and tumor stain. Interobserver and intermodality agreement was assessed by K statistics. RESULTS: For 4D-CE-MRA, the interobserver agreement was fair with respect to the main arterial feeders and very good for the degree of tumor stain (k = 0.28 and 0.87, respectively). Intermodality agreement was moderate for the main arterial feeders (k = 0.45) and good for the tumor stain (k = 0.74). CONCLUSIONS: Although 4D-CE-MRA may be useful for evaluating tumor stain in hypervascular brain and head and neck tumors, it is not able to replace DSA in planning interventional procedures.
引用
收藏
页码:445 / 448
页数:4
相关论文
共 17 条
[1]   Dynamic contrast enhancement of paragangliomas of the head and neck: evaluation with time-resolved 2D MR projection angiography [J].
Arnold, SM ;
Strecker, R ;
Scheffler, K ;
Spreer, J ;
Schipper, J ;
Neumann, HPH ;
Klisch, J .
EUROPEAN RADIOLOGY, 2003, 13 (07) :1608-1611
[2]   Intracranial arteriovenous malformations: Real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography - Initial assessment [J].
Farb, RI ;
McGregor, C ;
Kim, JK ;
Laliberte, M ;
Derbyshire, JA ;
Willinsky, RA ;
Cooper, PW ;
Westman, DG ;
Cheung, G ;
Schwartz, ML ;
Stainsby, JA ;
Wright, GA .
RADIOLOGY, 2001, 220 (01) :244-251
[3]   Embolization of Vascular Tumors of the Head and Neck [J].
Gemmete, Joseph J. ;
Ansari, Sameer A. ;
McHugh, Jonathan ;
Gandhi, Dheeraj .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (02) :181-+
[4]   Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography [J].
Kim, JK ;
Farb, RI ;
Wright, GA .
RADIOLOGY, 1998, 206 (01) :283-289
[5]   Quantitative and qualitative characterization of vascularization and hemodynamics in head and neck tumors with a 3D magnetic resonance time-resolved echo-shared angiographic technique (TREAT) - initial results [J].
Michaely, H. J. ;
Herrmann, K. A. ;
Dietrich, O. ;
Reiser, M. F. ;
Schoenberg, S. O. .
EUROPEAN RADIOLOGY, 2007, 17 (04) :1101-1110
[6]   Head and neck paragangliomas: Value of contrast-enhanced 3D MR angiography [J].
Neves, F. ;
Huwart, L. ;
Jourdan, G. ;
Reizine, D. ;
Herman, P. ;
Vicaut, E. ;
Guichard, J. P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) :883-889
[7]   Evaluation of Dural Arteriovenous Fistulas with 4D Contrast-Enhanced MR Angiography at 3T [J].
Nishimura, S. ;
Hirai, T. ;
Sasao, A. ;
Kitajima, M. ;
Morioka, M. ;
Kai, Y. ;
Omori, Y. ;
Okuda, T. ;
Murakami, R. ;
Fukuoka, H. ;
Awai, K. ;
Kuratsu, J. -I. ;
Yamashita, Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (01) :80-85
[8]   Evaluation of Image Quality of a 32-Channel versus a 12-Channel Head Coil at 1.5T for MR Imaging of the Brain [J].
Parikh, P. T. ;
Sandhu, G. S. ;
Blackham, K. A. ;
Coffey, M. D. ;
Hsu, D. ;
Liu, K. ;
Jesberger, J. ;
Griswold, M. ;
Sunshine, J. L. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (02) :365-373
[9]   Dynamic MRA With Four-Dimensional Time-Resolved Angiography Using Keyhole at 3 Tesla in Head and Neck Vascular Lesions [J].
Parmar, Hemant ;
Ivancevic, Marko K. ;
Dudek, Nancy ;
Gandhi, Dheeraj ;
Mukherji, Suresh K. .
JOURNAL OF NEURO-OPHTHALMOLOGY, 2009, 29 (02) :119-127
[10]   Human Hippocampal Subfields in Young Adults at 7.0 T: Feasibility of Imaging [J].
Prudent, Vasthie ;
Kumar, Arun ;
Liu, Songtao ;
Wiggins, Graham ;
Malaspina, Dolores ;
Gonen, Oded .
RADIOLOGY, 2010, 254 (03) :900-906