Radiation tolerance of ultra-thin PIN silicon detectors evaluated with a MeV proton microbeam

被引:2
作者
Abdel, Naseem S. [1 ]
Pallon, Jan [1 ]
Elfman, Mikael [1 ]
Kristiansson, Per [1 ]
Nilsson, E. J. Charlotta [1 ]
Ros, Linus [1 ]
机构
[1] Lund Univ, Dept Phys, Div Nucl Phys, SE-22100 Lund, Sweden
关键词
Ultra-thin detectors; Silicon detectors; Radiation damage; Charge collection efficiency; Microbeam facility; DAMAGE;
D O I
10.1016/j.nimb.2015.04.016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A focused MeV proton beam at the Lund Ion Beam Analysis Facility has been used to induce radiation damage in transmission semiconductor detectors. The damage alters the response of detectors and degrades their charge transport properties. In this work, the radiation tolerance of ultra-thin silicon PIN detectors was studied as a function of proton fluences and detector thickness using a scanning proton microprobe. The investigated detectors had thicknesses ranging between 6.5 and 22 mu m, and different selected regions of each detector were irradiated with fluence up to 2 x 10(15) protons/cm(2). The results show that the charge collection efficiency (CCE) decreases as a function of the proton fluence. Compared with non-irradiated regions, the CCE was above 94% at the lowest fluence of 2 x 10(12) protons/cm(2) for all the detectors studied. Degradation of the devices caused spectral peak shifting toward lower energies. The highest possible fluence of 2.55 MeV protons that could be used, causing only minor radiation damage, was 2 x 10(13) cm(-2) for the thinnest detectors (6.5 and 10 mu m) and 2 x 10(12) cm(-2) for the thickest detectors (15 and 22 mu m). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 21
页数:5
相关论文
共 19 条
[1]  
Abdel N.S., 2014, JINST J, V9
[2]   Fabrication and Characterization of Ultra-Thin PIN Silicon Detectors for Counting the Passage of MeV Ions [J].
Abdel, Naseem ;
Pallon, Jan ;
Graczyk, Mariusz ;
Maximov, Ivan ;
Wallman, Lars .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) :1182-1188
[3]   Radiation hardness and charge collection efficiency of lithium irradiated thin silicon diodes [J].
Boscardin, M ;
Bruzzi, M ;
Candelori, A ;
Dalla Betta, GF ;
Focardi, E ;
Khomenkov, V ;
Piemonte, C ;
Ronchin, S ;
Tosi, C ;
Zorzi, N .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) :1048-1053
[4]   Radiation damage in silicon detectors for high-energy physics experiments [J].
Bruzzi, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :960-971
[5]   FRENKEL PAIRS IN SILICON AND GERMANIUM [J].
EMTSEV, VV ;
MASHOVETS, TV ;
MIKHNOVICH, VV ;
VITOVSKII, NA .
RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1989, 112 (1-2) :99-118
[6]   Thin detectors for the CHICSi Delta E-E telescope [J].
Evensen, L ;
Westgaard, T ;
Avdeichikov, V ;
Carlen, L ;
Jakobsson, B ;
Murin, Y ;
Martensson, J ;
Oskarsson, A ;
Siwek, A ;
Whitlow, HJ ;
vanVeldhuizen, EJ ;
Westerber, L ;
Guttormsen, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :629-634
[7]   An ultra-thin Schottky diode as a transmission particle detector for biological microbeams [J].
Grad, M. ;
Harken, A. ;
Randers-Pehrson, G. ;
Attinger, D. ;
Brenner, D. J. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[8]   An ultra-thin diamond membrane as a transmission particle detector and vacuum window for external microbeams [J].
Grilj, V. ;
Skukan, N. ;
Pomorski, M. ;
Kada, W. ;
Iwamoto, N. ;
Kamiya, T. ;
Ohshima, T. ;
Jaksic, M. .
APPLIED PHYSICS LETTERS, 2013, 103 (24)
[9]  
Jaksic M., 2013, P SPIE, V8725
[10]  
Jaksic M., 2013, JINST J, V8