Reproducibility of fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope

被引:31
作者
Lois, N
Halfyard, AS
Bunce, C
Bird, AC
Fitzke, FW
机构
[1] Moorfields Eye Hosp, Med Retina Serv, London EC1V 2PD, England
[2] Inst Ophthalmol, London, England
关键词
D O I
10.1136/bjo.83.3.276
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim-To evaluate the reproducibility of the background fundus autofluorescence measurements obtained using a confocal scanning laser ophthalmoscope. Methods-10 normal volunteers and 10 patients with retinal disease were included in the study. One eye per subject was chosen randomly. Five images of the same eye of each individual were obtained, after pupillary dilatation, by two investigators using a confocal scanning laser ophthalmoscope. Background fundus autofluorescence was measured at 7 degrees temporal to the fovea in normal volunteers and between 7 and 15 degrees temporal to the fovea in patients. Within session reproducibility of the measurements obtained by each investigator and interobserver reproducibility were evaluated. Results-For investigator 1 the median values of fundus autofluorescence obtained were 31.9 units for normal volunteers and 27.3 units for patients. The median largest difference in readings in normal volunteers was 5.7 units (range 1.4-13.5 units) and in patients 4.2 units (1.5-15.1 units). For investigator 2 the median values of fundus autofluorescence obtained were 28.9 units for normal volunteers and 27.4 units for patients. The median largest difference in readings in normal volunteers was 3.6 units (2.7-11.7 units), and in patients 4.1 units (1.5-9.3 units). The median interobserver difference in readings in normal volunteers was 3.3 units and for patients 6.6 units. The median greatest interobserver difference in measurements obtained for normal volunteers was 8.8 units (8.4-23.0 units) and for patients 11.1 units (7.1-40.8 units). Conclusion-Within session reproducibility of the measurements of background fundus autofluorescence was satisfactory. Although interobserver reproducibility was moderate, the variability of the measurements of fundus autofluorescence between observers appears to be small when compared with variation in fundus autofluorescence with age and disease.
引用
收藏
页码:276 / 279
页数:4
相关论文
共 21 条
  • [1] BIRNBACH CD, 1994, OPHTHALMOLOGY, V101, P1211
  • [2] DELORI FC, 1995, INVEST OPHTH VIS SCI, V36, P2327
  • [3] SPECTROPHOTOMETER FOR NONINVASIVE MEASUREMENT OF INTRINSIC FLUORESCENCE AND REFLECTANCE OF THE OCULAR FUNDUS
    DELORI, FC
    [J]. APPLIED OPTICS, 1994, 33 (31): : 7439 - 7452
  • [4] DELORI FC, 1995, INVEST OPHTH VIS SCI, V36, P718
  • [5] DOREY CK, 1989, INVEST OPHTH VIS SCI, V30, P1691
  • [6] EAGLE RC, 1980, OPHTHALMOLOGY, V87, P1189
  • [7] FEENEY L, 1978, INVEST OPHTH VIS SCI, V17, P583
  • [8] AGE-RELATED-CHANGES IN THE ULTRASTRUCTURE OF BRUCHS MEMBRANE
    FEENEYBURNS, L
    ELLERSIECK, MR
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1985, 100 (05) : 686 - 697
  • [9] FEENEYBURNS L, 1984, INVEST OPHTH VIS SCI, V25, P195
  • [10] LIPOFUSCIN OF HUMAN RETINAL-PIGMENT EPITHELIUM
    FEENEYBURNS, L
    BERMAN, ER
    ROTHMAN, H
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1980, 90 (06) : 783 - &