Laser light sources for photobiomodulation: The role of power and beam characterization in treatment accuracy and reliability

被引:3
作者
Girasol, Carlos Eduardo [1 ]
Braz, Guilherme de Araujo [2 ]
Bachmann, Luciano [3 ]
Celli, Jonathan [4 ]
de Jesus Guirro, Rinaldo Roberto [1 ]
机构
[1] Univ Sao Paulo, Ribeirao Preto Med Sch, Dept Hlth Sci, Postgrad Program Rehabil & Funct Performance, Ribeirao Preto, SP, Brazil
[2] Technol Ctr Supera Pk Innovat & Technol Ribeirao, Ribeirao Preto, SP, Brazil
[3] Univ Sao Paulo, Postgrad Program Phys Appl Med & Biol, Ribeirao Preto, SP, Brazil
[4] Univ Massachusetts, Dept Phys, Boston, MA 02125 USA
来源
PLOS ONE | 2022年 / 17卷 / 03期
基金
巴西圣保罗研究基金会;
关键词
CALIBRATION; EQUIPMENT; WIDTH;
D O I
10.1371/journal.pone.0266193
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeDaily clinical use of therapeutic light sources can lead to changes in light emission stability with potentially significant consequences for usage in photomedicine treatment. The aim of this study was to evaluate the average and maximum power and to describe the beam diameter of different low-power laser photobiomodulation devices in clinical use in Brazil. MethodsThe power and light-emitting beam diameter of twenty-four therapeutic devices with an average age of 11 +/- 5 years, with an average weekly use of fewer than thirty minutes, were measured. ResultsThe analyzed power varied between 2% to 134% of the values declared by the manufacturers. Differences in beam diameter of between 38% and 543% of the nominal values were also observed. It is also noteworthy that even between the same brand and model, differences in diameter were obtained. Finally, differences were observed in the power output after one and three minutes of sequential emission for 830 nm and 904 nm (p < 0.05), but not when comparing the difference between wavelengths in factor time. ConclusionThere is a need for a shared effort on the part of laser manufacturers to improve standardization and consistency of laser output power and beam diameters. At the same time, medical laser operators should also consider development of standardized protocols for maintenance and monitoring equipment performance over time to correct for fluctuations that could ultimately impact on treatment outcomes.
引用
收藏
页数:12
相关论文
共 22 条
[1]   A calibration study of therapeutic ultrasound units [J].
Artho, PA ;
Thyne, JG ;
Warring, BP ;
Willis, CD ;
Brismée, JM ;
Latman, NS .
PHYSICAL THERAPY, 2002, 82 (03) :257-263
[2]   Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods [J].
Ash, Caerwyn ;
Dubec, Michael ;
Donne, Kelvin ;
Bashford, Tim .
LASERS IN MEDICAL SCIENCE, 2017, 32 (08) :1909-1918
[3]  
Associacao Brasileira de Normas Tecnicas, 2010, 606011 NBR IEC ASS B, V1
[4]  
Associacao Brasileira de Normas Tecnicas, 2014, 6060118 NBR IEC ASS, V1
[5]   Analysis of low-level laser transmission at wavelengths 660, 830 and 904 nm in biological tissue samples [J].
Barbosa, Rafael Inacio ;
de Oliveira Guirro, Elaine Caldeira ;
Bachmann, Luciano ;
Brandino, Hugo Evangelista ;
de Jesus Guirro, Rinaldo Roberto .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2020, 209
[6]   The Nuts and Bolts of Low-level Laser (Light) Therapy [J].
Chung, Hoon ;
Dai, Tianhong ;
Sharma, Sulbha K. ;
Huang, Ying-Ying ;
Carroll, James D. ;
Hamblin, Michael R. .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (02) :516-533
[7]   Is there a measure for low power laser dose? [J].
da Fonseca, Adenilson de Souza .
LASERS IN MEDICAL SCIENCE, 2019, 34 (01) :223-234
[8]  
Guirro RRD, 2014, J PHYS THER SCI, V26, P557, DOI 10.1589/jpts.26.557
[9]   Radiant Power Determination of Low-Level Laser Therapy Equipment and Characterization of Its Clinical Use Procedures [J].
de Jesus Guirro, Rinaldo Roberto ;
Weis, Luciana Cezimbra .
PHOTOMEDICINE AND LASER SURGERY, 2009, 27 (04) :633-639
[10]   Intricacies of Dose in Laser Phototherapy for Tissue Repair and Pain Relief [J].
Enwemeka, Chukuka S. .
PHOTOMEDICINE AND LASER SURGERY, 2009, 27 (03) :387-393