Comparative motility of hydroxyapatite and alloplastic enucleation implants

被引:57
作者
Custer, PL
Trinkaus, KM
Fornoff, J
机构
[1] Washington Univ, Dept Ophthalmol & Visual Sci, St Louis, MO 63130 USA
[2] Washington Univ, Div Biostat, St Louis, MO 63130 USA
[3] Illinois Dept Publ Hlth, Springfield, IL 62761 USA
关键词
D O I
10.1016/S0161-6420(99)90109-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To compare the motility of scleral-covered hydroxyapatite and alloplastic enucleation implants. Design: Retrospective, nonrandomized comparative trial. Participants: Measurements were obtained after surgery in 76 anophthalmic patients who had received either hydroxyapatite or alloplastic enucleation implants. Methods/Main Outcome Measures: Horizontal and vertical excursions of the enucleation implants. Results: There is no clinically important difference between the movement of hydroxyapatite and alloplastic enucleation implants, implant movement appears to decline with advancing age. Conclusion: Scleral-covered alloplastic and hydroxyapatite enucleation implants show similar movement. Although directly coupling hydroxyapatite implants to the prosthesis via the motility peg provides enhanced prosthetic movement, there appears to be no motility benefit of nonpegged hydroxyapatite over spherical alloplastic implants.
引用
收藏
页码:513 / 516
页数:4
相关论文
共 16 条