An open-labelled randomized controlled trial comparing costs and clinical outcomes of open endotracheal suctioning with closed endotracheal suctioning in mechanically ventilated medical intensive care patients

被引:19
作者
David, Deepu [1 ]
Samuel, Prasanna [2 ]
David, Thambu [1 ]
Keshava, Shyamkumar Nidugala [3 ]
Irodi, Aparna [3 ]
Peter, John Victor [4 ]
机构
[1] Christian Med Coll & Hosp, Dept Med 2, Vellore 632004, Tamil Nadu, India
[2] Christian Med Coll & Hosp, Dept Biostat, Vellore 632004, Tamil Nadu, India
[3] Christian Med Coll & Hosp, Dept Radiodiag, Vellore 632004, Tamil Nadu, India
[4] Christian Med Coll & Hosp, Med Intens Care Unit, Vellore 632004, Tamil Nadu, India
关键词
Endotracheal; Suctioning; Ventilator-associated pneumonia; Mortality; Outcome; TRACHEAL SUCTION; PNEUMONIA; SYSTEM; CONTAMINATION; PREVENTION; CATHETERS; DIAGNOSIS;
D O I
10.1016/j.jcrc.2010.10.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: Closed endotracheal suctioning (CES) may impact ventilator- associated pneumonia (VAP) risk by reducing environmental contamination. In developing countries where resource limitations constrain the provision of optimal bed space for critically ill patients, CES assumes greater importance. Materials and Methods: In this prospective, open-labeled, randomized controlled trial spanning 10 months, we compared CES with open endotracheal suctioning (OES) in mechanically ventilated patients admitted to the medical intensive care unit (ICU) of a university-affiliated teaching hospital. Patients were followed up from ICU admission to death or discharge from hospital. Primary outcome was incidence of VAP. Secondary outcomes included mortality, cost, and length of stay. Results: Two hundred patients were recruited, 100 in each arm. The incidence of VAP was 23.5%. Closed endotracheal suctioning was associated with a trend to a reduced incidence of VAP (odds ratio, 1.86; 95% confidence interval, 0.91-3.83; P = .067). A significant benefit was, however, observed with CES for late-onset VAP (P = .03). Mortality and duration of ICU and hospital stay were similar in the 2 groups. The cost of suction catheters and gloves was significantly higher with CES (Rs 272 [US $5.81] vs Rs 138 [US $2.94], P < .0001). Nine patients need to be treated with CES to prevent 1 VAP (95% confidence interval, -0.7 to 22). Conclusions: In the ICU setting in a developing country, CES may be advantageous in reducing the incidence of VAP, particularly late-onset VAP. These results mandate further studies in this setting before specific guidelines regarding the routine use of CES are proposed. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:482 / 488
页数:7
相关论文
共 31 条
[1]  
Adams D H, 1997, Intensive Crit Care Nurs, V13, P72, DOI 10.1016/S0964-3397(97)80135-8
[2]   Ventilator associated pneumonia and infection control [J].
Alp E. ;
Voss A. .
Annals of Clinical Microbiology and Antimicrobials, 5 (1)
[3]   Incidence, risk factors and mortality of nosocomial pneumonia in intensive care units: A prospective study [J].
Alp E. ;
Güven M. ;
Yildiz O. ;
Aygen B. ;
Voss A. ;
Doganay M. .
Annals of Clinical Microbiology and Antimicrobials, 3 (1)
[5]   ENVIRONMENTAL CONTAMINATION DURING TRACHEAL SUCTION - A COMPARISON OF DISPOSABLE CONVENTIONAL CATHETERS WITH A MULTIPLE-USE CLOSED SYSTEM DEVICE [J].
COBLEY, M ;
ATKINS, M ;
JONES, PL .
ANAESTHESIA, 1991, 46 (11) :957-961
[6]  
Darvas Jenny A, 2003, Aust Crit Care, V16, P86, DOI 10.1016/S1036-7314(03)80005-X
[7]  
Dey Arindam, 2007, Ann Thorac Med, V2, P52, DOI 10.4103/1817-1737.32230
[8]   Evidence-based clinical practice guideline for the prevention of ventilator-associated pneumonia [J].
Dodek, P ;
Keenan, S ;
Cook, D ;
Heyland, D ;
Jacka, M ;
Hand, L ;
Muscedere, J ;
Foster, D ;
Mehta, N ;
Hall, R ;
Brun-Buisson, C .
ANNALS OF INTERNAL MEDICINE, 2004, 141 (04) :305-313
[9]   Clinical diagnosis of ventilator associated pneumonia revisited:: comparative validation using immediate post-mortem lung biopsies [J].
Fàbregas, N ;
Ewig, S ;
Torres, A ;
El-Ebiary, M ;
Ramirez, J ;
de la Bellacasa, JP ;
Bauer, T ;
Cabello, H .
THORAX, 1999, 54 (10) :867-873
[10]   Prolonged application of closed in-line suction catheters increases microbial colonization of the lower respiratory tract and bacterial growth on catheter surface [J].
Freytag, CC ;
Thies, FL ;
König, W ;
Welte, T .
INFECTION, 2003, 31 (01) :31-37