Added value of three-dimensional transesophageal echocardiography in management of mitral paravalvular leaks

被引:6
作者
Mahmoud-Elsayed, Hani [1 ]
机构
[1] Univ Hosp Birmingham NHS Fdn Trust, CardioVasc Imaging Cardiol Dept, Queen Elizabeth Hosp Birmingham, Birmingham, W Midlands, England
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2020年 / 37卷 / 06期
关键词
mitral valve prosthesis; percutaneous intervention; three-dimensional transesophageal echocardiography; CLOSURE; REGURGITATION;
D O I
10.1111/echo.14708
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthetic paravalvular leak (PVL) is a well-known serious complication following surgically as well as percutaneously implanted prosthetic valves. It usually happens due to incomplete sealing of the prosthetic ring to the native cardiac tissue whether immediately postoperative or considerably later as a complication of infective endocarditis, etc Surgery has been always the treatment of choice for clinically significant PVLs. However, percutaneous transcatheter closure therapy has become a successful alternative in carefully selected group of patients. Echocardiography is a cornerstone in the initial diagnosis, assessment of the severity and location of the PVL. Furthermore, it plays a crucial role in the assessment of the feasibility for percutaneous closure and during intra-procedural guidance. Transesophageal echocardiography (TEE) has the advantage over transthoracic echocardiography (TTE) of not being affected by the acoustic shadow of the mitral prosthesis that usually hides the regurgitation jets and makes TTE evaluation difficult. Three-dimensional (3D) TEE has been shown to provide better diagnostic accuracy compared to two-dimensional (2D) TEE as regard to evaluation of PVLs especially in patients with more than one PVL. This is due to better delineation of the location, shape, and size of the PVL and equally important during guiding the transcatheter percutaneous closure.
引用
收藏
页码:954 / 964
页数:11
相关论文
共 14 条
  • [1] Utility of Real-Time Three-Dimensional Transesophageal Echocardiography in Evaluating the Success of Percutaneous Transcatheter Closure of Mitral Paravalvular Leaks
    Angel Garcia-Fernandez, Miguel
    Cortes, Marcelino
    Garcia-Robles, Jose A.
    Gomez de Diego, Jose J.
    Perez-David, Esther
    Garcia, Eulogio
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (01) : 26 - 32
  • [2] Three-Dimensional Color Doppler Transesophageal Echocardiography for Mitral Paravalvular Leak Quantification and Evaluation of Percutaneous Closure Success
    Franco, Eduardo
    Almeria, Carlos
    Alberto de Agustin, Jose
    Arreo del Val, Viviana
    Gomez de Diego, Jose Juan
    Garcia Fernandez, Miguel Angel
    Macaya, Carlos
    Perez de Isla, Leopoldo
    Garcia, Eulogio
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (11) : 1153 - 1163
  • [3] Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography
    Ionescu, A
    Fraser, AG
    Butchart, EG
    [J]. HEART, 2003, 89 (11) : 1316 - 1321
  • [4] Percutaneous Transcatheter Closure of Prosthetic Mitral Paravalvular Leaks Are We There Yet?
    Kim, Michael S.
    Casserly, Ivan P.
    Garcia, Joel A.
    Klein, Andrew J.
    Salcedo, Ernesto E.
    Carroll, John D.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (02) : 81 - 90
  • [5] Review of surgical prosthetic paravalvular leaks: diagnosis and catheter-based closure
    Kliger, Chad
    Eiros, Rocio
    Isasti, Guillermo
    Einhorn, Bryce
    Jelnin, Vladimir
    Cohen, Howard
    Kronzon, Itzhak
    Perk, Gila
    Fontana, Gregory P.
    Ruiz, Carlos E.
    [J]. EUROPEAN HEART JOURNAL, 2013, 34 (09) : 638 - +
  • [6] Percutaneous Paravalvular Leak Closure
    Kumar, Robert
    Jelnin, Vladimir
    Kliger, Chad
    Ruiz, Carlos E.
    [J]. CARDIOLOGY CLINICS, 2013, 31 (03) : 431 - +
  • [7] EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
    Lang, Roberto M.
    Badano, Luigi P.
    Tsang, Wendy
    Adams, David H.
    Agricola, Eustachio
    Buck, Thomas
    Faletra, Francesco F.
    Franke, Andreas
    Hung, Judy
    Perez de Isla, Leopoldo
    Kamp, Otto
    Kasprzak, Jaroslaw D.
    Lancellotti, Patrizio
    Marwick, Thomas H.
    McCulloch, Marti L.
    Monaghan, Mark J.
    Nihoyannopoulos, Petros
    Pandian, Natesa G.
    Pellikka, Patricia A.
    Pepi, Mauro
    Roberson, David A.
    Shernan, Stanton K.
    Shirali, Girish S.
    Sugeng, Lissa
    Ten Cate, Folkert J.
    Vannan, Mani A.
    Luis Zamorano, Jose
    Zoghbi, William A.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (01) : 1 - 46
  • [8] Cardiac imaging in prosthetic paravalvular leaks
    Lazaro, Carla
    Hinojar, Rocio
    Luis Zamorano, Jose
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (04) : 307 - 313
  • [9] A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study
    Mahmoud, Hani M.
    Al-Ghamdi, Mohammed A.
    Ghabashi, Abdullah E.
    Anwar, Ashraf M.
    [J]. CARDIOLOGY RESEARCH AND PRACTICE, 2015, 2015
  • [10] Usefulness of 3D transoesophageal echocardiography for guiding wires and closure devices in mitral perivalvular leaks
    Manuel Becerra, Jose
    Almeria, Carlos
    Perez de Isla, Leopoldo
    Zamorano, Jose
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (08): : 979 - 981