Gamma dose rate effects in luminescence signals of various artificial, well established dosimetric phosphors

被引:3
作者
Polymeris, George S. [1 ]
Basdogan, Miray [1 ,2 ]
Cakal, Gaye O. [1 ]
Aslar, Engin [1 ]
Meric, Niyazi [1 ]
机构
[1] Ankara Univ, Inst Nucl Sci, TR-06100 Ankara, Turkey
[2] Turkish Atom Energy Commiss, Dept Radiat & Accelerator Technol, TR-06983 Ankara, Turkey
关键词
LiB4O7:Cu; In; MgB4O7:Dy; Na; LiF:Mg; Ti; CaF2:Dy; BeO; OSL; TL; Deconvolution; Dose rate; Dose response; Kinetic parameters; COMPUTERIZED CURVE DECONVOLUTION; BEO CERAMICS; THERMOLUMINESCENCE; PARAMETERS; DEPENDENCE;
D O I
10.1016/j.radmeas.2020.106282
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The present work attempts to study tentative gamma dose rate effects for the stable TL and OSL signals of specific, well established artficial luminescence dosimeters. Two different dose rates of gamma radiation (2 and 31 Gy/h) were used. The study has been performed to the stable TL peaks of 5 different TL phosphors (LiB4O7:Cu,In; MgB4O7:Dy,Na; LiF:Mg,Ti; CaF2:Dy; BeO) as well as to both OSL components of BeO. Tentative dose rate effects were studied for both dosimetric dose response features as well as kinetic parameters after deconvolution for both signals. Two different groups of materials were revealed. The first one includes materials such as LiF: Mg,Ti, BeO and MgB4O7: Dy,Na; for these, both TL dose response features and TL kinetic parameters are independent on the dose rate. This is also the case for both OSL components of BeO besides the linearity index of the dose response of the fast OSL component; the latter seems to mildly depend on the dose rate. At the same time, experimental arguments based on both dosimetric as well as deconvolution features suggest the presence of tentative dose rate effects for the cases of LiB4O7:Cu, In and CaF2:Dy. Moreover, the effective use of these aforementioned features as probes for identification of dose rate effects is also discussed. The results of the present study suggest that the basic postulate of most phenomenological TL models that traps pre-exist and they are simply filled during irradiation has to be reconsidered.
引用
收藏
页数:4
相关论文
共 13 条
  • [1] Searching for TL/OSL dose rate effects in various luminescent materials
    Mrozik, Anna
    Bilski, Pawel
    Mandowski, Arkadiusz
    Klosowski, Mariusz
    Budzanowski, Maciej
    Drop, Jagoda
    Swakon, Jan
    Discher, Michael
    RADIATION MEASUREMENTS, 2024, 176
  • [2] Dose rate effects on the then-no luminescence properties of HFCVD diamonds
    Gastelum, S.
    Cruz-Zaragoza, E.
    Favalli, A.
    Melendrez, R.
    Chernov, V.
    Barboza-Flores, M.
    DIAMOND AND RELATED MATERIALS, 2008, 17 (7-10) : 1283 - 1287
  • [3] Dosimetric characterisation of the optically-stimulated luminescence dosimeter in cobalt-60 high dose rate brachytherapy system
    Rejab, M.
    Wong, J. H. D.
    Jamalludin, Z.
    Jong, W. L.
    Malik, R. A.
    Ishak, W. Z. Wan
    Ung, N. M.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 475 - 485
  • [4] Effects of Gamma Irradiation Dose-Rate on Sterile Male Aedesaegypti
    Ernawan, Beni
    Tambunan, UsmanSumo Friend
    Sugoro, Irawan
    Sasmita, HadianIman
    PROCEEDING OF INTERNATIONAL BIOLOGY CONFERENCE 2016: BIODIVERSITY AND BIOTECHNOLOGY FOR HUMAN WELFARE, 2017, 1854
  • [5] Identification and quantification of anomalies in environmental gamma dose rate time series using artificial intelligence
    Breitkreutz, Harald
    Mayr, Josef
    Bleher, Martin
    Seifert, Stefan
    Stoehlker, Ulrich
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2023, 259
  • [6] Effects of dose and dose rate of gamma ray irradiation on mutation induction and nuclear DNA content in chrysanthemum
    Yamaguchi, Hiroyasu
    Shimizu, Akemi
    Degi, Konosuke
    Morishita, Toshikazu
    BREEDING SCIENCE, 2008, 58 (03) : 331 - 335
  • [7] Dose Rate and Bias Effects on COTS Array CCDs Induce Dark Signals Increase
    Wang Zujun
    He Baoping
    Yao Zhibin
    Liu Minbo
    Sheng Jiangkun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1376 - 1380
  • [8] Dose rate effects on the performance of MWCVD diamond films as TL gamma radiation dosimeter
    Cruz-Zaragoza, E.
    Gastelum, S.
    Melendrez, R.
    Chernov, V.
    Barboza-Flores, M.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2010, 207 (08): : 1944 - 1948
  • [9] Gamma-radiation dose-rate effects on DNA damage and toxicity in bacterial cells
    Jiho Min
    Chang Woo Lee
    Man Bock Gu
    Radiation and Environmental Biophysics, 2003, 42 : 189 - 192
  • [10] Characterizing low dose and dose rate effects in rodent and human neural stem cells exposed to proton and gamma irradiation
    Tseng, Bertrand P.
    Lan, Mary L.
    Tran, Katherine K.
    Acharya, Munjal M.
    Giedzinski, Erich
    Limoli, Charles L.
    REDOX BIOLOGY, 2013, 1 (01): : 153 - 162