Novel chemiluminometric H2O2 sensors for the selective flow injection analysis

被引:16
|
作者
Janasek, D
Spohn, U
Beckmann, D
机构
[1] Univ Halle Wittenberg, Inst Biotechnol, D-06120 Halle, Germany
[2] Inst Bioproc & Analyt Measurement Tech Heiligenst, D-37308 Heiligenstadt, Germany
关键词
chemiluminescence sensor; gas dialysis; hydrogen peroxide;
D O I
10.1016/S0925-4005(98)00177-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen peroxide can be detected chemiluminometrically in the presence of luminol at cobalt and copper foils. The chemiluminescence signal can also be induced electrochemically. The linear determination ranges are 0.1-200 mu M on cobalt and 5-2000 mu M on copper under flow injection conditions. To improve the selectivity the chemiluminescence detector was combined with a thin layer gas dialysis cell. Hydrogen peroxide was detected in the range between 0.5 and 100 mM. The interference by a more than 100-fold excess of EDTA, alpha-ketocarboxylic acids and peroxodisulfate can be excluded. Peroxomonosulfate concentrations greater than a ten-fold excess of hydrogen peroxide cause a significant bias, which resulted from the hydrolysis of peroxomonosulfate. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 50 条
  • [1] CHEMILUMINOMETRIC ENZYME SENSORS FOR FLOW-INJECTION ANALYSIS
    SPOHN, U
    PREUSCHOFF, F
    BLANKENSTEIN, G
    JANASEK, D
    KULA, MR
    HACKER, A
    ANALYTICA CHIMICA ACTA, 1995, 303 (01) : 109 - 120
  • [2] MWCNT-chitosan composite chemically modified electrode as an electrochemical detector for highly Selective flow injection analysis of H2O2
    Gayathri, Prakasam
    Kumar, Annamalai Senthil
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2015, 92 (04) : 485 - 488
  • [3] Flow Injection Amperometric Analysis of H2O2 at Platinum Nanoparticles Modified Pencil Graphite Electrode
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2017, 29 (06) : 1626 - 1634
  • [4] H2O2 response gene 1/2 are novel sensors or responders of H2O2 and involve in maintaining embryonic root meristem activity in Arabidopsis thalianak
    Gong, Feng
    Yao, Zhuang
    Liu, Yi
    Sun, Mengxiang
    Peng, Xiongbo
    PLANT SCIENCE, 2021, 310
  • [5] Improved flow injection analysis of H2O2 on cinder/Prussian Blue-modified electrodes by CTAB micelles
    Zen, JM
    Chen, PY
    Kumar, AS
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2002, 49 (05) : 915 - 920
  • [6] Catalysis of metalloporphyrins for selective hydroxylation of phenol by H2O2
    Zeng, Hai-Qiang
    Jiang, Quan
    Zhu, Yun-Fei
    Yan, Xu-Hui
    Liang, Xue-Bo
    Hu, Hai-Yang
    Liu, Qiang
    Lin, Wei-ying
    Guo, Can-Cheng
    JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2006, 10 (02) : 96 - 103
  • [7] Selective flotation of chalcopyrite and molybdenite with H2O2 oxidation
    Hirajima, Tsuyoshi
    Miki, Hajime
    Suyantara, Gde Pandhe Wisnu
    Matsuoka, Hidekazu
    Elmandy, Ahmed Mohamed
    Sasaki, Keiko
    Imaizumi, Yuji
    Kuroiwa, Shigeto
    MINERALS ENGINEERING, 2017, 100 : 83 - 92
  • [8] Recent developments in selective catalytic epoxidations with H2O2
    Arends, IWCE
    Sheldon, RA
    TOPICS IN CATALYSIS, 2002, 19 (01) : 133 - 141
  • [9] Recent Developments in Selective Catalytic Epoxidations with H2O2
    I.W.C.E. Arends
    R.A. Sheldon
    Topics in Catalysis, 2002, 19 : 133 - 141
  • [10] Simultaneous detection of NADH and H2O2 using flow injection analysis based on a bifunctional poly(thionine)-modified electrode
    Baskar, Selvaraj
    Chang, Jen-Lin
    Zen, Jyh-Myng
    BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) : 95 - 99