The usefulness of 3D MR angiography in surgery for ruptured cerebral aneurysms

被引:26
作者
Watanabe, Z [1 ]
Kikuchi, Y [1 ]
Izaki, K [1 ]
Hanyu, N [1 ]
Lim, FSH [1 ]
Gotou, H [1 ]
Koizumi, J [1 ]
Gotou, T [1 ]
Kowada, M [1 ]
Watanabe, K [1 ]
机构
[1] So Tohoku Gen Hosp, So Tohoku Res Inst Neurosci, Dept Neurosurg, Koriyama, Fukushima, Japan
来源
SURGICAL NEUROLOGY | 2001年 / 55卷 / 06期
关键词
3D MRA; aneurysm; SAH; surgery;
D O I
10.1016/S0090-3019(01)00452-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND We have used magnetic resonance angiography (MRA) in screening for unruptured cerebral aneurysms since 1993. The development of high-resolution magnetic resonance (MR) imaging has led to a remarkable improvement in image quality. Three-dimensional (3D) MRA can be used for surgical simulation. Here, we report on the usefulness of and problems associated with 3D MRA for the surgery of ruptured cerebral aneurysms. METHODS Between June 1998 and June 2000, 106 patients with SAH diagnosed by 3D MRA underwent surgery. We compared 3D MRA images with operative findings and investigated the usefulness of this assessment tool. RESULTS In 48 of 106 cases (45.3%), we were able to perform surgery based on 3D MRA alone. By using the 3D images, we could easily detect the relative location of the aneurysm, its neck and the surrounding arteries. The remaining cases required further examinations because of uncertainty of diagnosis or insufficient information. CONCLUSION 3D MRA is a safe and useful procedure for the diagnosis and surgery of ruptured cerebral aneurysms. However, in approximately half of all cases, 3D computed tomographic angiography (CTA) or digital subtraction angiography (DSA) is required in addition for the planning of surgery. It is important to use 3D MRA for surgery only after taking sufficient consideration of certain limitations peculiar to MRA. (C) 2001 by Elsevier Science Inc.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 11 条
[1]  
Berteloot D, 1999, J RADIOL, V80, P843
[2]   Value of 3-D-MT-TONE-Time-of-Flight magnetic resonance angiography in the detection of intracranial aneurysms in comparison to digital subtraction angiography - A prospective study [J].
Falk, A ;
Schmieder, K ;
Hentsch, A ;
Harders, A ;
Heuser, L .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1996, 164 (01) :31-37
[3]   COMPARISON OF 3-DIMENSIONAL PHASE-CONTRAST MAGNETIC-RESONANCE ANGIOGRAPHY WITH 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY IN CEREBRAL ANEURYSMS [J].
IKAWA, F ;
SUMIDA, M ;
UOZUMI, T ;
KUWABARA, S ;
KIYA, K ;
KURISU, K ;
ARITA, K ;
SATOH, H .
SURGICAL NEUROLOGY, 1994, 42 (04) :287-292
[4]   The usefulness of magnetic resonance angiography in surgery for intracranial aneurysms that have bled [J].
Keogh, AJ ;
Vhora, S .
SURGICAL NEUROLOGY, 1998, 50 (02) :122-127
[5]   Neurologic complications of cerebral angiography - A retrospective study of complication rate and patient risk factors [J].
Leffers, AM ;
Wagner, A .
ACTA RADIOLOGICA, 2000, 41 (03) :204-210
[6]  
MATSUMOTO M, IN PRESS J NEUROSURG
[7]  
Okuyama T, 1997, NEUROL SURG TOKYO, V25, P1073
[8]  
SATO M, 2000, J STROKE CEREBROV S1, V9, P152
[9]  
TANABE S, 1995, NEUROL SURG TOKYO, V23, P787
[10]   Comparison of magnetic resonance angiography with conventional angiography in the detection of intracranial aneurysms in patients presenting with subarachnoid haemorrhage [J].
Wilcock, D ;
Jaspan, T ;
Holland, I ;
Cherryman, G ;
Worthington, B .
CLINICAL RADIOLOGY, 1996, 51 (05) :330-334