Identification of a matrix effect in the MC-ICP-MS due to sample purification using ion exchange resin: An isotopic case study of molybdenum

被引:39
作者
Pietruszka, Aaron J. [1 ]
Reznik, Audrey D. [1 ]
机构
[1] San Diego State Univ, Dpt Geol Sci, San Diego, CA 92182 USA
关键词
molybdenum; isotope; mass spectrometry; MC-ICP-MS; matrix effect;
D O I
10.1016/j.ijms.2007.11.001
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has become the preferred method for precise and accurate measurements of the relative abundances of many radiogenic and stable isotopes in natural materials. Isotopic analyses by MC-ICP-MS require a correction for instrumental mass-dependent isotopic fractionation ("instrumental mass bias"). Two techniques have been used to correct for instrumental mass bias in the MC-ICP-MS: (1) standard-sample bracketing (SSB) or (2) double spiking. SSB is often cited as the preferred method, but it is more susceptible to matrix effects. Here we demonstrate that a matrix effect in the MC-ICP-MS may arise indirectly from the chemical separation and purification of molybdenum using anion exchange resin. The results of our experiments show that a Mo standard passed through a column of anion exchange resin or a Mo standard added to a Mo-free solution that had been collected from anion exchange resin appears to be isotopically lighter than expected from direct analysis of the same standard. Using amounts of Mo similar to what might be expected from most natural samples (similar to 3 mu g per column cut), these offsets span a significant fraction (similar to 10-60%) of the total known range of mass-dependent Mo isotopic variation in nature. This "column matrix effect" appears to be caused by organic material stripped from the resin. All of our attempts to eliminate or control this column matrix effect have failed, making it difficult (if not impossible) to obtain accurate measurements of mass-dependent Mo isotopic variations in natural materials using the anion exchange resin procedure described in this study and SSB techniques to correct for instrumental mass bias in the MC-ICP-MS. It is currently unknown if this type of column matrix effect will affect measurements of other stable or radiogenic isotopes by MC-ICP-MS when SSB is used to correct for instrumental mass bias. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 25 条
[1]   Analytical methods for non-traditional isotopes [J].
Albarède, F ;
Beard, B .
GEOCHEMISTRY OF NON-TRADITIONAL STABLE ISOTOPES, 2004, 55 :113-152
[2]   Precise and accurate isotopic measurements using multiple-collector ICPMS [J].
Albarède, F ;
Telouk, P ;
Blichert-Toft, J ;
Boyet, M ;
Agranier, A ;
Nelson, B .
GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (12) :2725-2744
[3]   Precise determination of mass-dependent variations in the isotopic composition of molybdenum using MC-ICPMS [J].
Anbar, AD ;
Knab, KA ;
Barling, J .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1425-1431
[4]   Fe isotope variations in natural materials measured using high mass resolution multiple collector ICPMS [J].
Arnold, GL ;
Weyer, S ;
Anbar, AD .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :322-327
[5]   Pb isotopic analysis of standards and samples using a 207Pb-204Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS [J].
Baker, J ;
Peate, D ;
Waight, T ;
Meyzen, C .
CHEMICAL GEOLOGY, 2004, 211 (3-4) :275-303
[6]   Natural mass-dependent variations in the isotopic composition of molybdenum [J].
Barling, J ;
Arnold, GL ;
Anbar, AD .
EARTH AND PLANETARY SCIENCE LETTERS, 2001, 193 (3-4) :447-457
[7]   Application of Fe isotopes to tracing the geochemical and biological cycling of Fe [J].
Beard, BL ;
Johnson, CM ;
Skulan, JL ;
Nealson, KH ;
Cox, L ;
Sun, H .
CHEMICAL GEOLOGY, 2003, 195 (1-4) :87-117
[8]   High precision measurement of iron isotopes by plasma source mass spectrometry [J].
Belshaw, NS ;
Zhu, XK ;
Guo, Y ;
O'Nions, RK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 197 :191-195
[9]   Matrix-induced isotopic mass fractionation in the ICP-MS [J].
Carlson, RW ;
Hauri, EH ;
Alexander, CMO .
PLASMA SOURCE MASS SPECTROMETRY: THE NEW MILLENNIUM, 2001, (267) :288-297
[10]   Molybdenum isotope variations in molybdenite: Vapor transport and Rayleigh fractionation of Mo [J].
Hannah, J. L. ;
Stein, H. J. ;
Wieser, M. E. ;
de Laeter, J. R. ;
Varner, M. D. .
GEOLOGY, 2007, 35 (08) :703-706