Automated Pupillometer Using Edge Detection in OpenCV for Pupil Size and Reactivity Assessment

被引:0
作者
Garcia, Ramon G. [1 ]
Avendano, Glenn O. [1 ]
Agdeppa, Denzel Blake F. [1 ]
Castillo, Ken J. [1 ]
Go, Neil Roger S. D. [1 ]
Mesina, Mikhail A. [1 ]
机构
[1] Mapua Univ, Sch Elect Elect & Comp Engn, Manila 1002, Philippines
来源
2019 3RD INTERNATIONAL CONFERENCE ON IMAGING, SIGNAL PROCESSING AND COMMUNICATION (ICISPC) | 2019年
关键词
Raspberry Pi; NoIR; Infrared; Pupillary assessment; Pupillometer; Inter-examiner variability; Digital Image Processing; Pupil Contour;
D O I
10.1109/icispc.2019.8935852
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measuring pupil size and reactivity in Pupillary assessment is a vital part of preliminary checkup among hospital patients, as it helps in determining neurological disorders. This measurement can be done by either manual or automated. In a manual assessment, which is often performed using a penlight and pupil gauge, there is no standardized protocol used for reactivity. Thus, results can vary due to room conditions and inter-examiner variability. This subjective assessment can lead to misconclusion between clinicians on classifying the health condition of patients. Whereas with automated, which can provide objective measuring through the use of electronics technology with complex algorithms. But automated pupillometers are still currently being used for research purposes. In line with this, the proposed automated pupillometer would like to aid medical personnel in conducting an objective assessment in order to avoid inter-examiner variability. In addition, the said device would procure test data for partnered doctors to assess subjectivity of pupil speed as brisk, sluggish, or non-reactive.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 10 条
[1]  
Balbin J. R., 2017, 2 INT WORKSH PATT RE, DOI [10.1117/12.228082, DOI 10.1117/12.228082]
[2]  
Bremner D., 2012, PUPILLOMETRIC EVALUA
[3]   Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study [J].
Couret, David ;
Boumaza, Delphine ;
Grisotto, Coline ;
Triglia, Thibaut ;
Pellegrini, Lionel ;
Ocquidant, Philippe ;
Bruder, Nicolas J. ;
Velly, Lionel J. .
CRITICAL CARE, 2016, 20
[4]  
Dotmed, 2016, DOTMED NEUROPTICS NP
[5]  
Gonzalez Maria Trinidad Galvan, 2017, ANAL PUPILLARY RESPO, DOI [10.1109/CONIELECOMP.2017.7891817, DOI 10.1109/CONIELECOMP.2017.7891817]
[6]   UNDERESTIMATION OF PUPIL SIZE BY CRITICAL CARE AND NEUROSURGICAL NURSES [J].
Kerr, Robert G. ;
Bacon, Andrea M. ;
Baker, Laura L. ;
Gehrke, Janelle S. ;
Hahn, K. Danielle ;
Lillegraven, Cheryl L. ;
Renner, Catherine Hackett ;
Spilman, Sarah K. .
AMERICAN JOURNAL OF CRITICAL CARE, 2016, 25 (03) :213-219
[7]  
NeurOptics, 2017, NPI 200 PUP SYST
[8]  
Padilla D. A., 2017, TENCON 2017 2017 IEE, DOI [10.1109/ tencon.2017.8228333, DOI 10.1109/TENCON.2017.8228333]
[9]  
Paglinawan A. C, 2017, 2017 IEEE 9 INT C HU, DOI [10.1109/ hnicem. 2017.8269550, DOI 10.1109/HNICEM.2017.8269550]
[10]  
Stutzman Sonja E., 2014, INTERRATER RELIABILI