Non-enzymatic hydrogen peroxide sensor based on graphene quantum dots-chitosan/methylene blue hybrid nanostructures

被引:84
|
作者
Mollarasouli, Fariba [1 ,2 ]
Asadpour-Zeynali, Karim [1 ]
Campuzano, Susana [2 ]
Yanez-Sedeno, Paloma [2 ]
Pingarron, Jose M. [2 ,3 ]
机构
[1] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz 5166616471, Iran
[2] Univ Complutense Madrid, Fac Ciencias Quim, Dept Quim Analit, E-28040 Madrid, Spain
[3] IMDEA Nanosci, Ciudad Univ Cantoblanco, Madrid 28049, Spain
关键词
Graphene quantum dots (GQDs); Methylene blue (MB); Chitosan (CS); Non-enzymatic electrochemical sensor; H2O2; METHYLENE-BLUE; AMPEROMETRIC DETERMINATION; FACILE SYNTHESIS; WASTE-WATER; LIVE CELLS; NANOPARTICLES; CARBON; CHEMILUMINESCENCE; ELECTRODE; H2O2;
D O I
10.1016/j.electacta.2017.06.003
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Graphene quantum dots (GQDs) functionalized with chitosan (GQDs-CS) were used for the first time as a suitable nanostructured sensing film for efficient immobilization of methylene blue (MB) through aminohydroxyl reaction to prepare a novel non-enzymatic hydrogen peroxide sensor using a glassy carbon electrode (GCE). The synthesized hybrid nanostructures were characterized by X-ray diffraction, field emission scanning electron microscopy, cyclic voltammetry, FT-IR, UV-vis, photoluminescence, and energy dispersive X-ray spectroscopy techniques. Cyclic voltammograms showed that the GQDs-CS/MB/GCE exhibited a significant electrocatalytic activity for the reduction of H2O2. The calculated k(cat) is 4.45 x 10(4)cm(3)mol(-1)s(-1). The calibration graph for H2O2 constructed by amperometry (-0.6 V vs. SCE) at the modified electrode showed two different linear ranges (1.0 x 10(-6)-2.9 x 10(-3)M and 2.9-11.78 mM) with a sensitivity of 10.115 mu A/mM for the lower linear range and a calculated detection limit of 0.7 mu M (S/N = 3). The response time of the sensor for H2O2 detection was 3s. The electrochemical response of GQDs-CS/MB/GCE is not influenced by potential interferents (ascorbic and uric acids, dopamine, caffeine, glucose, and various inorganic salts). This modified electrode exhibited suitability for the non-enzymatic H2O2 sensing in food and water samples. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 50 条
  • [21] A sensitive non-enzymatic electrochemical sensor based on acicular manganese dioxide modified graphene nanosheets composite for hydrogen peroxide detection
    Guan, Jin-Feng
    Huang, Zhao-Ning
    Zou, Jiao
    Jiang, Xin-Yu
    Peng, Dong-Ming
    Yu, Jin-Gang
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2020, 190
  • [22] Facile construction of an Ag/MoSe2 composite based non-enzymatic amperometric sensor for hydrogen peroxide
    Tian, Ran
    Li, Dong
    Zhou, Tao
    Chu, Xue-Qiang
    Ge, Danhua
    Chen, Xiaojun
    DALTON TRANSACTIONS, 2022, 51 (13) : 5271 - 5277
  • [23] Non-enzymatic hydrogen peroxide sensor based on Co3O4 nanocubes
    Cao, Guang Sheng
    Wang, Lei
    Yuan, Pengfei
    Gao, Chao
    Liu, Xiaojuan
    Li, Tong
    Li, Tianmin
    BULLETIN OF MATERIALS SCIENCE, 2014, 37 (06) : 1369 - 1373
  • [24] A Highly Sensitive Non-Enzymatic Hydrogen Peroxide Sensor based on Palladium-Gold Nanoparticles
    Banerjee, Saikat
    Hossain, Md Faruk
    Slaughter, Gymama
    2020 IEEE 15TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEM (IEEE NEMS 2020), 2020, : 286 - 289
  • [25] A non-enzymatic hydrogen peroxide sensor based on vertical NiO nanosheets supported on the graphite sheet
    Liu, Wei
    Zhang, Hongxiu
    Yang, Bin
    Li, Zhongjian
    Lei, Lecheng
    Zhang, Xingwang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 749 : 62 - 67
  • [26] A Non-Enzymatic Glucose Sensor Based on the Hybrid Thin Films of Cu on Acetanilide/ITO
    Sajadpour, Maryam
    Siampour, Hossein
    Abbasian, Sara
    Amiri, Masoud
    Rameshan, Raffael
    Rameshan, Christoph
    Hajian, Ali
    Bagheri, Hasan
    Moshaii, Ahmad
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1116 - B1125
  • [27] Fabrication of Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on Ag NPs/Co3O4/ERGO Composite
    Mirzaei, Mohammad
    Behboudnia, Mahdi
    Kheiri, Farshad
    Chianeh, Vahid Abbasi
    Naeim, Haleh
    Jannatdoust, Elham
    Sirousazar, Mohammad
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (13) : B1232 - B1237
  • [28] Highly branched gold-copper nanostructures for non-enzymatic specific detection of glucose and hydrogen peroxide
    Ngamaroonchote, Aroonsri
    Sanguansap, Yanisa
    Wutikhun, Tuksadon
    Karn-orachai, Kullavadee
    MICROCHIMICA ACTA, 2020, 187 (10)
  • [29] Synthesis of a CuNP/chitosan/black phosphorus nanocomposite for non-enzymatic hydrogen peroxide sensing
    Zhao, Yun
    Zhuge, Zhen
    Tang, Yi-Hong
    Tao, Jian-Wei
    ANALYST, 2020, 145 (22) : 7260 - 7266
  • [30] A Non-enzymatic Ag/δ-FeOOH Sensor for Hydrogen Peroxide Determination using Disposable Carbon-based Electrochemical Cells
    de Meira, Flavio H. A.
    Resende, Sayton F.
    Monteiro, Douglas S.
    Pereira, Marcio C.
    Mattoso, Luiz H. C.
    Faria, Ronaldo C.
    Afonso, Andre S.
    ELECTROANALYSIS, 2020, 32 (10) : 2231 - 2236