Enzyme-free glucose sensor using a glassy carbon electrode modified with reduced graphene oxide decorated with mixed copper and cobalt oxides

被引:49
|
作者
Li, Su-Juan [1 ]
Hou, Lin-Lin [1 ]
Yuan, Bai-Qing [1 ]
Chang, Meng-Zhu [1 ]
Ma, Yu [1 ]
Du, Ji-Min [1 ]
机构
[1] Anyang Normal Univ, Coll Chem & Chem Engn, Key Lab Clearer Energy & Funct Mat Henan Prov, Anyang 455000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Nanocomposite; Nanoporous material; Nonenzymatic sensing; Binary catalyst; Electrocatalytic oxidation; Cyclic voltammetry; Scanning electron microscopy; Energy dispersive X-ray spectroscopy; STEP ELECTROCHEMICAL SYNTHESIS; CUO NANOPARTICLES; HYDROGEN-PEROXIDE; HYBRID; NANOSTRUCTURES; NANOCOMPOSITE; NANOSHEETS; FILM;
D O I
10.1007/s00604-016-1817-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a binary porous catalyst consisting of a reduced graphene oxide (rGO) support decorated with mixed Cu-Co oxides. It was synthesized electrochemically and characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy and cyclic voltammetry. The nanocomposite was deposited on a glassy carbon electrode (GCE) where it exhibits better electrocatalytic activities for glucose oxidation compared to GCEs modified with CuOx or CoOx only on an rGO support. The improved electrocatalytic activities are believed to result from the synergistic effect of CuOx-CoOx binary catalyst, the high conductivity of rGO support, and the porous scaffold. The amperometric sensor, operated in 0.1 M NaOH at a working potential of +0.5 V (vs. SCE), displays a calibration plot for glucose that is linear in the 5 to 570 mu M concentration range, and the detection limit is 0.5 mu M. The performance of the sensor was evaluated by determination of glucose in (spiked) human urine.
引用
收藏
页码:1813 / 1821
页数:9
相关论文
共 50 条
  • [1] Enzyme-free glucose sensor using a glassy carbon electrode modified with reduced graphene oxide decorated with mixed copper and cobalt oxides
    Su-Juan Li
    Lin-Lin Hou
    Bai-Qing Yuan
    Meng-Zhu Chang
    Yu Ma
    Ji-Min Du
    Microchimica Acta, 2016, 183 : 1813 - 1821
  • [2] Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles
    Heidari, Hassan
    Habibi, Esmaeil
    MICROCHIMICA ACTA, 2016, 183 (07) : 2259 - 2266
  • [3] Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles
    Hassan Heidari
    Esmaeil Habibi
    Microchimica Acta, 2016, 183 : 2259 - 2266
  • [4] Enzyme-free sensing of hydrogen peroxide and glucose at a CuS nanoflowers modified glassy carbon electrode
    Yang, Yu Jun
    Zi, Junfeng
    Li, Weikun
    ELECTROCHIMICA ACTA, 2014, 115 : 126 - 130
  • [5] Sensitive and Enzyme-Free Glucose Sensor Based on Copper Nanowires/Polyaniline/Reduced Graphene Oxide Nanocomposite Ink
    Anand, Vijay Kumar
    Bhatt, Kapil
    Kumar, Sandeep
    Archana, B.
    Sharma, Sandeep
    Singh, Karamvir
    Gupta, Monish
    Goyal, Rakesh
    Virdi, G. S.
    INTERNATIONAL JOURNAL OF NANOSCIENCE, 2021, 20 (02)
  • [6] Enzyme-free amperometric glucose sensor using a glassy carbon electrode modified with poly(vinyl butyral) incorporating a hybrid nanostructure composed of molybdenum disulfide and copper sulfide
    Gao, Zhuangqiang
    Lin, Yuping
    He, Yu
    Tang, Dianping
    MICROCHIMICA ACTA, 2017, 184 (03) : 807 - 814
  • [7] Dendritic copper-cobalt nanostructures/reduced graphene oxide-chitosan modified glassy carbon electrode for glucose sensing
    Wang, Li
    Zheng, Yaolin
    Lu, Xingping
    Li, Zhuang
    Sun, Lanlan
    Song, Yonghai
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 1 - 7
  • [8] Electrochemical Determination of Nitrite Using a Reduced Graphene Oxide-Multiwalled Carbon Nanotube-Modified Glassy Carbon Electrode
    Deng, Keqin
    Zhou, Jianhong
    Huang, Haowen
    Ling, Yulin
    Li, Chunxiang
    ANALYTICAL LETTERS, 2016, 49 (18) : 2917 - 2930
  • [9] Highly sensitive nonenzymatic glucose sensor based on nickel nanoparticle-attapulgite-reduced graphene oxide-modified glassy carbon electrode
    Shen, Zongxu
    Gao, Wenyu
    Li, Pei
    Wang, Xiaofang
    Zheng, Qing
    Wu, Hao
    Ma, Yuehui
    Guan, Weijun
    Wu, Songmei
    Yu, Yu
    Ding, Kejian
    TALANTA, 2016, 159 : 194 - 199
  • [10] Amperometric nonenzymatic determination of glucose via a glassy carbon electrode modified with nickel hydroxide and N-doped reduced graphene oxide
    Zhang, Yuehua
    Lei, Wu
    Wu, Qiuju
    Xia, Xifeng
    Hao, Qingli
    MICROCHIMICA ACTA, 2017, 184 (09) : 3103 - 3111